2,144 research outputs found

    I Can See Your Aim: Estimating User Attention From Gaze For Handheld Robot Collaboration

    Get PDF
    This paper explores the estimation of user attention in the setting of a cooperative handheld robot: a robot designed to behave as a handheld tool but that has levels of task knowledge. We use a tool-mounted gaze tracking system, which, after modelling via a pilot study, we use as a proxy for estimating the attention of the user. This information is then used for cooperation with users in a task of selecting and engaging with objects on a dynamic screen. Via a video game setup, we test various degrees of robot autonomy from fully autonomous, where the robot knows what it has to do and acts, to no autonomy where the user is in full control of the task. Our results measure performance and subjective metrics and show how the attention model benefits the interaction and preference of users.Comment: this is a corrected version of the one that was published at IROS 201

    Robotic Handle Prototypes for Endoscopic Endonasal Skull Base Surgery: Pre-clinical Randomised Controlled Trial of Performance and Ergonomics

    Get PDF
    Endoscopic endonasal skull base surgery is a promising alternative to transcranial approaches. However, standard instruments lack articulation, and thus, could benefit from robotic technologies. The aim of this study was to develop an ergonomic handle for a handheld robotic instrument intended to enhance this procedure. Two different prototypes were developed based on ergonomic guidelines within the literature. The first is a forearm-mounted handle that maps the surgeon’s wrist degrees-of-freedom to that of the robotic end-effector; the second is a joystick-and-trigger handle with a rotating body that places the joystick to the position most comfortable for the surgeon. These handles were incorporated into a custom-designed surgical virtual simulator and were assessed for their performance and ergonomics when compared with a standard neurosurgical grasper. The virtual task was performed by nine novices with all three devices as part of a randomised crossover user-study. Their performance and ergonomics were evaluated both subjectively by themselves and objectively by a validated observational checklist. Both handles outperformed the standard instrument with the rotating joystick-body handle offering the most substantial improvement in terms of balance between performance and ergonomics. Thus, it is deemed the more suitable device to drive instrumentation for endoscopic endonasal skull base surgery

    A 5-DOFs Robot for Posterior Segment Eye Microsurgery

    Get PDF
    In retinal surgery clinicians access the internal volume of the eyeball through small scale trocar ports, typically 0.65 mm in diameter, to treat vitreoretinal disorders like idiopathic epiretinal membrane and age-related macular holes. The treatment of these conditions involves the removal of thin layers of diseased tissue, namely the epiretinal membrane and the internal limiting membrane. These membranes have an average thickness of only 60 μm and 2 μm respectively making extremely challenging even for expert clinicians to peel without damaging the surrounding tissue. In this work we present a novel Ophthalmic microsurgery Robot (OmSR) designed to operate a standard surgical forceps used in these procedures with micrometric precision, overcoming the limitations of current robotic systems associated with the offsetting of the remote centre of motion of the end effector when accessing the sclera. The design of the proposed system is presented, and its performance evaluated. The results show that the end effector can be controlled with an accuracy of less than 30 μm and the surgical forceps opening and closing positional error is less than 4.3 μm. Trajectory-following experiments and membrane peeling experiments are also presented, showing promising results in both scenarios

    Bridging the Research Gap: Making HRI Useful to Individuals with Autism

    Get PDF
    While there is a rich history of studies involving robots and individuals with autism spectrum disorders (ASD), few of these studies have made substantial impact in the clinical research community. In this paper we first examine how differences in approach, study design, evaluation, and publication practices have hindered uptake of these research results. Based on ten years of collaboration, we suggest a set of design principles that satisfy the needs (both academic and cultural) of both the robotics and clinical autism research communities. Using these principles, we present a study that demonstrates a quantitatively measured improvement in human-human social interaction for children with ASD, effected by interaction with a robot

    Haptics in Robot-Assisted Surgery: Challenges and Benefits

    Get PDF
    Robotic surgery is transforming the current surgical practice, not only by improving the conventional surgical methods but also by introducing innovative robot-enhanced approaches that broaden the capabilities of clinicians. Being mainly of man-machine collaborative type, surgical robots are seen as media that transfer pre- and intra-operative information to the operator and reproduce his/her motion, with appropriate filtering, scaling, or limitation, to physically interact with the patient. The field, however, is far from maturity and, more critically, is still a subject of controversy in medical communities. Limited or absent haptic feedback is reputed to be among reasons that impede further spread of surgical robots. In this paper objectives and challenges of deploying haptic technologies in surgical robotics is discussed and a systematic review is performed on works that have studied the effects of providing haptic information to the users in major branches of robotic surgery. It has been tried to encompass both classical works and the state of the art approaches, aiming at delivering a comprehensive and balanced survey both for researchers starting their work in this field and for the experts

    User-centered design of a dynamic-autonomy remote interaction concept for manipulation-capable robots to assist elderly people in the home

    Get PDF
    In this article, we describe the development of a human-robot interaction concept for service robots to assist elderly people in the home with physical tasks. Our approach is based on the insight that robots are not yet able to handle all tasks autonomously with sufficient reliability in the complex and heterogeneous environments of private homes. We therefore employ remote human operators to assist on tasks a robot cannot handle completely autonomously. Our development methodology was user-centric and iterative, with six user studies carried out at various stages involving a total of 241 participants. The concept is under implementation on the Care-O-bot 3 robotic platform. The main contributions of this article are (1) the results of a survey in form of a ranking of the demands of elderly people and informal caregivers for a range of 25 robot services, (2) the results of an ethnography investigating the suitability of emergency teleassistance and telemedical centers for incorporating robotic teleassistance, and (3) a user-validated human-robot interaction concept with three user roles and corresponding three user interfaces designed as a solution to the problem of engineering reliable service robots for home environments

    The future of robotic surgery

    Get PDF
    © 2018 Royal College of Surgeons.For 20 years Intuitive Surgical’s da Vinci® system has held the monopoly in minimally invasive robotic surgery. Restrictive patenting, a well-developed marketing strategy and a high-quality product have protected the company’s leading market share.1 However, owing to the nuances of US patenting law, many of Intuitive Surgical’s earliest patents will be expiring in the next couple of years. With such a shift in backdrop, many of Intuitive Surgical’s competitors (from medical and industrial robotic backgrounds) have initiated robotic programmes – some of which are available for clinical use now. The next section of the review will focus on new and developing robotic systems in the field of minimally invasive surgery (Table 1), single-site surgery (Table 2), natural orifice transluminal endoscopic surgery (NOTES) and non-minimally invasive robotic systems (Table 3).Peer reviewedFinal Published versio

    Chronic Postoperative Pain After Robot-Assisted Laparoscopic Hysterectomy for Endometrial Cancer

    Get PDF

    Ergonomics in Laparoscopic Surgery

    Get PDF
    Despite the many advantages for patients, laparoscopic surgery entails certain ergonomic inconveniences for surgeons, which may result in decreasing the surgeons’ performance and musculoskeletal disorders. In this chapter, the current status of ergonomics in laparoscopy, laparoendoscopic single‐site surgery (LESS), and robot‐assisted surgery will be reviewed. Ergonomic guidelines for laparoscopic surgical practice and methods for ergonomic assessment in surgery will be described. Results will be based on the scientific literature and our experience. Results showed that the surgeon\u27s posture during laparoscopic surgery is mainly affected by the static body postures, the height of the operating table, the design of the surgical instruments, the position of the main screen, and the use of foot pedals. Ergonomics during the laparoscopic surgical practice is related to the level of experience. Better ergonomic conditions entail an improvement in task performance. Laparoscopic instruments with axial handle lead to a more ergonomic posture for the wrist compared to a ring handle. LESS is physically more demanding than conventional and hybrid approaches, requiring greater level of muscular activity in the back and arm muscles, but better wrist position compared with traditional laparoscopy. Physical and cognitive ergonomics with robotic assistance were significantly less challenging when compared to conventional laparoscopic surgery
    corecore