28,773 research outputs found
Digital Color Imaging
This paper surveys current technology and research in the area of digital
color imaging. In order to establish the background and lay down terminology,
fundamental concepts of color perception and measurement are first presented
us-ing vector-space notation and terminology. Present-day color recording and
reproduction systems are reviewed along with the common mathematical models
used for representing these devices. Algorithms for processing color images for
display and communication are surveyed, and a forecast of research trends is
attempted. An extensive bibliography is provided
Quality criteria benchmark for hyperspectral imagery
Hyperspectral data appear to be of a growing interest
over the past few years. However, applications for hyperspectral
data are still in their infancy as handling the significant size of
the data presents a challenge for the user community. Efficient
compression techniques are required, and lossy compression,
specifically, will have a role to play, provided its impact on remote
sensing applications remains insignificant. To assess the data
quality, suitable distortion measures relevant to end-user applications
are required. Quality criteria are also of a major interest
for the conception and development of new sensors to define their
requirements and specifications. This paper proposes a method to
evaluate quality criteria in the context of hyperspectral images.
The purpose is to provide quality criteria relevant to the impact
of degradations on several classification applications. Different
quality criteria are considered. Some are traditionnally used in
image and video coding and are adapted here to hyperspectral
images. Others are specific to hyperspectral data.We also propose
the adaptation of two advanced criteria in the presence of different
simulated degradations on AVIRIS hyperspectral images. Finally,
five criteria are selected to give an accurate representation of the
nature and the level of the degradation affecting hyperspectral
data
GPU accelerated real-time multi-functional spectral-domain optical coherence tomography system at 1300 nm.
We present a GPU accelerated multi-functional spectral domain optical coherence tomography system at 1300 nm. The system is capable of real-time processing and display of every intensity image, comprised of 512 pixels by 2048 A-lines acquired at 20 frames per second. The update rate for all four images with size of 512 pixels by 2048 A-lines simultaneously (intensity, phase retardation, flow and en face view) is approximately 10 frames per second. Additionally, we report for the first time the characterization of phase retardation and diattenuation by a sample comprised of a stacked set of polarizing film and wave plate. The calculated optic axis orientation, phase retardation and diattenuation match well with expected values. The speed of each facet of the multi-functional OCT CPU-GPU hybrid acquisition system, intensity, phase retardation, and flow, were separately demonstrated by imaging a horseshoe crab lateral compound eye, a non-uniformly heated chicken muscle, and a microfluidic device. A mouse brain with thin skull preparation was imaged in vivo and demonstrated the capability of the system for live multi-functional OCT visualization
Small unmanned airborne systems to support oil and gas pipeline monitoring and mapping
Acknowledgments We thank Johan Havelaar, Aeryon Labs Inc., AeronVironment Inc. and Aeronautics Inc. for kindly permitting the use of materials in Fig. 1.Peer reviewedPublisher PD
Recommended from our members
Artificial Intelligence in Gastrointestinal Endoscopy.
Artificial intelligence (AI) is rapidly integrating into modern technology and clinical practice. Although in its nascency, AI has become a hot topic of investigation for applications in clinical practice. Multiple fields of medicine have embraced the possibility of a future with AI assisting in diagnosis and pathology applications. In the field of gastroenterology, AI has been studied as a tool to assist in risk stratification, diagnosis, and pathologic identification. Specifically, AI has become of great interest in endoscopy as a technology with substantial potential to revolutionize the practice of a modern gastroenterologist. From cancer screening to automated report generation, AI has touched upon all aspects of modern endoscopy. Here, we review landmark AI developments in endoscopy. Starting with broad definitions to develop understanding, we will summarize the current state of AI research and its potential applications. With innovation developing rapidly, this article touches upon the remarkable advances in AI-assisted endoscopy since its initial evaluation at the turn of the millennium, and the potential impact these AI models may have on the modern clinical practice. As with any discussion of new technology, its limitations must also be understood to apply clinical AI tools successfully
Recent Advances and the Potential for Clinical Use of Autofluorescence Detection of Extra-Ophthalmic Tissues
The autofluorescence (AF) characteristics of endogenous fluorophores allow the label-free assessment and visualization of cells and tissues of the human body. While AF imaging (AFI) is well-established in ophthalmology, its clinical applications are steadily expanding to other disciplines. This review summarizes clinical advances of AF techniques published during the past decade. A systematic search of the MEDLINE database and Cochrane Library databases was performed to identify clinical AF studies in extra-ophthalmic tissues. In total, 1097 articles were identified, of which 113 from internal medicine, surgery, oral medicine, and dermatology were reviewed. While comparable technological standards exist in diabetology and cardiology, in all other disciplines, comparability between studies is limited due to the number of differing AF techniques and non-standardized imaging and data analysis. Clear evidence was found for skin AF as a surrogate for blood glucose homeostasis or cardiovascular risk grading. In thyroid surgery, foremost, less experienced surgeons may benefit from the AF-guided intraoperative separation of parathyroid from thyroid tissue. There is a growing interest in AF techniques in clinical disciplines, and promising advances have been made during the past decade. However, further research and development are mandatory to overcome the existing limitations and to maximize the clinical benefits
A Novel Long-term, Multi-Channel and Non-invasive Electrophysiology Platform for Zebrafish.
Zebrafish are a popular vertebrate model for human neurological disorders and drug discovery. Although fecundity, breeding convenience, genetic homology and optical transparency have been key advantages, laborious and invasive procedures are required for electrophysiological studies. Using an electrode-integrated microfluidic system, here we demonstrate a novel multichannel electrophysiology unit to record multiple zebrafish. This platform allows spontaneous alignment of zebrafish and maintains, over days, close contact between head and multiple surface electrodes, enabling non-invasive long-term electroencephalographic recording. First, we demonstrate that electrographic seizure events, induced by pentylenetetrazole, can be reliably distinguished from eye or tail movement artifacts, and quantifiably identified with our unique algorithm. Second, we show long-term monitoring during epileptogenic progression in a scn1lab mutant recapitulating human Dravet syndrome. Third, we provide an example of cross-over pharmacology antiepileptic drug testing. Such promising features of this integrated microfluidic platform will greatly facilitate high-throughput drug screening and electrophysiological characterization of epileptic zebrafish
- âŠ