20 research outputs found

    Automatic artifacts removal from epileptic EEG using a hybrid algorithm

    Get PDF
    Electroencephalogram (EEG) examination plays a very important role in the diagnosis of disorders related to epilepsy in clinic. However, epileptic EEG is often contaminated with lots of artifacts such as electrocardiogram (ECG), electromyogram (EMG) and electrooculogram (EOG). These artifacts confuse EEG interpretation, while rejecting EEG segments containing artifacts probably results in a substantial data loss and it is very time-consuming. The purpose of this study is to develop a novel algorithm for removing artifacts from epileptic EEG automatically. The collected multi-channel EEG data are decomposed into statistically independent components with Independent Component Analysis (ICA). Then temporal and spectral features of each independent component, including Hurst exponent, skewness, kurtosis, largest Lyapunov exponent and frequency-band energy extracted with wavelet packet decomposition, are calculated to quantify the characteristics of different artifact components. These features are imported into trained support vector machine to determine whether the independent components represent EEG activity or artifactual signals. Finally artifact-free EEGs are obtained by reconstructing the signal with artifact-free components. The method is evaluated with EEG recordings acquired from 15 epilepsy patients. Compared with previous work, the proposed method can remove artifacts such as baseline drift, ECG, EMG, EOG, and power frequency interference automatically and efficiently, while retaining important features for epilepsy diagnosis such as interictal spikes and ictal segments

    A new method to detect event-related potentials based on Pearson\u2019s correlation

    Get PDF
    Event-related potentials (ERPs) are widely used in brain-computer interface applications and in neuroscience. Normal EEG activity is rich in background noise, and therefore, in order to detect ERPs, it is usually necessary to take the average from multiple trials to reduce the effects of this noise. The noise produced by EEG activity itself is not correlated with the ERP waveform and so, by calculating the average, the noise is decreased by a factor inversely proportional to the square root of N, where N is the number of averaged epochs. This is the easiest strategy currently used to detect ERPs, which is based on calculating the average of all ERP\u2019s waveform, these waveforms being time- and phase-locked. In this paper, a new method called GW6 is proposed, which calculates the ERP using a mathematical method based only on Pearson\u2019s correlation. The result is a graph with the same time resolution as the classical ERP and which shows only positive peaks representing the increase\u2014in consonance with the stimuli\u2014in EEG signal correlation over all channels. This new method is also useful for selectively identifying and highlighting some hidden components of the ERP response that are not phase-locked, and that are usually hidden in the standard and simple method based on the averaging of all the epochs. These hidden components seem to be caused by variations (between each successive stimulus) of the ERP\u2019s inherent phase latency period (jitter), although the same stimulus across all EEG channels produces a reasonably constant phase. For this reason, this new method could be very helpful to investigate these hidden components of the ERP response and to develop applications for scientific and medical purposes. Moreover, this new method is more resistant to EEG artifacts than the standard calculations of the average and could be very useful in research and neurology. The method we are proposing can be directly used in the form of a process written in the well-known Matlab programming language and can be easily and quickly written in any other software language

    Effects of the adhd syndrome on the frequency composition of ERPs revealed by independent component analysis

    No full text
    In this study, we investigated the frequency characteristics of independent components (ICs) of event-related potentials (ERPs) recorded in persons with attention deficit/hyperactivity disorder (ADHD) and normal adults under conditions of continuous performance test (CPT). A group of 50 participants (10 ADHD subjects and 40 ones with no attention disorders) was examined. Independent component analysis was applied to the recorded signals. For ERP extraction, averages for each group of ICs, which were time-locked to the onset of stimuli, were calculated. Several frequency characteristics (704 items) were extracted from different ERPs in each IC. Eight features of the brain signals had a significant (P < 0.001) correlation with the participants’ clinical presentation, which is consistent with the results of previous studies. The revealed promising relation can be used for further evaluation of the sustained attention level.У роботі вивчали частотні характеристики пов’язаних з подією ЕЕГ-потенціалів (ППП) у дорослих тестованих з наявністю синдрому дефіциту уваги й гіперактивності (ADHD) та його відсутністю (норма) в умовах тесту безперервного виконання (continuous performance test, CPT). Дослідження були проведені на 50 добровольцях (10 тестованих з наявністю ADHD і 40 практично здорових людей). Для вивчення ППП використовували методику незалежного компонентного аналізу. Середні величини для кожної групи незалежних компонентів (НК), „прив’язаних” до моменту пред’явлення стимулу, розраховували, щоб описати ППП. У кожному НК у складі різних ППП було виділено низку частотних особливостей (усього 704 риси). Як виявилося, вісім таких рис досліджуваних ППП вірогідно (P < < 0.001) корелювали з клінічними характеристиками тестованих, що узгоджується з результатами, отриманими в попередніх роботах. Наші дані можуть бути використані для об’єктивної оцінки рівня підт римуваної уваги

    EEG filtering based on blind source separation (BSS) for early detection of Alzheimer's disease

    Get PDF
    Objective: Development of an EEG preprocessing technique for improvement of detection of Alzheimer’s disease (AD). The technique is based on filtering of EEG data using blind source separation (BSS) and projection of components which are possibly sensitive to cortical neuronal impairment found in early stages of AD. Method: Artifact-free 20 s intervals of raw resting EEG recordings from 22 patients with Mild Cognitive Impairment (MCI) who later proceeded to AD and 38 age-matched normal controls were decomposed into spatio-temporally decorrelated components using BSS algorithm ‘AMUSE’. Filtered EEG was obtained by back projection of components with the highest linear predictability. Relative power of filtered data in delta, theta, alpha1, alpha2, beta1, and beta 2 bands were processed with Linear Discriminant Analysis (LDA). Results: Preprocessing improved the percentage of correctly classified patients and controls computed with jack-knifing cross-validation from 59 to 73% and from 76 to 84%, correspondingly. Conclusions: The proposed approach can significantly improve the sensitivity and specificity of EEG based diagnosis. Significance: Filtering based on BSS can improve the performance of the existing EEG approaches to early diagnosis of Alzheimer’s disease. It may also have potential for improvement of EEG classification in other clinical areas or fundamental research. The developed method is quite general and flexible, allowing for various extensions and improvements. q 2004 Published by Elsevier Ireland Ltd. on behalf of International Federation of Clinical Neurophysiology

    Artifact removal in magnetoencephalogram background activity with independent component analysis

    Get PDF
    The aim of this study was to assess whether independent component analysis (ICA) could be valuable to remove power line noise, cardiac, and ocular artifacts from magnetoencephalogram (MEG) background activity. The MEGs were recorded from 11 subjects with a 148-channel whole-head magnetometer. We used a statistical criterion to estimate the number of independent components. Then, a robust ICA algorithm decomposed the MEG epochs and several methods were applied to detect those artifacts. The whole process had been previously tested on synthetic data. We found that the line noise components could be easily detected by their frequency spectrum. In addition, the ocular artifacts could be identified by their frequency characteristics and scalp topography. Moreover, the cardiac artifact was better recognized by its skewness value than by its kurtosis one. Finally, the MEG signals were compared before and after artifact rejection to evaluate our method

    How do the resting EEG preprocessing states affect the outcomes of postprocessing?

    Full text link
    Plenty of artifact removal tools and pipelines have been developed to correct the EEG recordings and discover the values below the waveforms. Without visual inspection from the experts, it is susceptible to derive improper preprocessing states, like the insufficient preprocessed EEG (IPE), and the excessive preprocessed EEG (EPE). However, little is known about the impacts of IPE or EPE on the postprocessing in the frequency, spatial and temporal domains, particularly as to the spectra and the functional connectivity (FC) analysis. Here, the clean EEG (CE) was synthesized as the ground truth based on the New-York head model and the multivariate autoregressive model. Later, the IPE and the EPE were simulated by injecting the Gaussian noise and losing the brain activities, respectively. Then, the impacts on postprocessing were quantified by the deviation caused by the IPE or EPE from the CE as to the 4 temporal statistics, the multichannel power, the cross spectra, the dispersion of source imaging, and the properties of scalp EEG network. Lastly, the association analysis was performed between the PaLOSi metric and the varying trends of postprocessing with the evolution of preprocessing states. This study shed light on how the postprocessing outcomes are affected by the preprocessing states and PaLOSi may be a potential effective quality metric

    Emotion Classification through Nonlinear EEG Analysis Using Machine Learning Methods

    Get PDF
    Background: Emotion recognition, as a subset of affective computing, has received considerable attention in recent years. Emotions are key to human-computer interactions. Electroencephalogram (EEG) is considered a valuable physiological source of information for classifying emotions. However, it has complex and chaotic behavior.Methods: In this study, an attempt is made to extract important nonlinear features from EEGs with the aim of emotion recognition. We also take advantage of machine learning methods such as evolutionary feature selection methods and committee machines to enhance the classification performance. Classification performed concerning both arousal and valence factors.Results: Results suggest that the proposed method is successful and comparable to the previous works. A recognition rate equal to 90% achieved, and the most significant features reported. We apply the final classification scheme to 2 different databases including our recorded EEGs and a benchmark dataset to evaluate the suggested approach.Conclusion: Our findings approve of the effectiveness of using nonlinear features and a combination of classifiers. Results are also discussed from different points of view to understand brain dynamics better while emotion changes. This study reveals useful insights about emotion classification and brain-behavior related to emotion elicitation
    corecore