55 research outputs found

    Biomechanical mechanisms underlying exosuit-induced improvements in walking economy after stroke

    Full text link
    Stroke-induced hemiparetic gait is characteristically asymmetric and metabolically expensive. Weakness and impaired control of the paretic ankle contribute to reduced forward propulsion and ground clearance—walking subtasks critical for safe and efficient locomotion. Targeted gait interventions that improve paretic ankle function after stroke are therefore warranted. We have developed textile-based, soft wearable robots that transmit mechanical power generated by off-board or body-worn actuators to the paretic ankle using Bowden cables (soft exosuits) and have demonstrated the exosuits can overcome deficits in paretic limb forward propulsion and ground clearance, ultimately reducing the metabolic cost of hemiparetic walking. This study elucidates the biomechanical mechanisms underlying exosuit-induced reductions in metabolic power. We evaluated the relationships between exosuit-induced changes in the body center of mass (COM) power generated by each limb, individual joint powers, and metabolic power. Compared to walking with an exosuit unpowered, exosuit assistance produced more symmetrical COM power generation during the critical period of the step-to-step transition (22.4±6.4% more symmetric). Changes in individual limb COM power were related to changes in paretic (R2= 0.83, P= 0.004) and nonparetic (R2= 0.73, P= 0.014) ankle power. Interestingly, despite the exosuit providing direct assistance to only the paretic limb, changes in metabolic power were related to changes in nonparetic limb COM power (R2= 0.80, P= 0.007), not paretic limb COM power (P> 0.05). These findings provide a fundamental understanding of how individuals poststroke interact with an exosuit to reduce the metabolic cost of hemiparetic walking.Accepted manuscript2019-03-0

    Altering gait variability with an ankle exoskeleton

    Get PDF
    Exoskeletons can influence human gait. A healthy gait is characterized by a certain amount of variability compared to a non-healthy gait that has more inherent variability; however which exoskeleton assistance parameters are necessary to avoid increasing gait variability or to potentially lower gait variability below that of unassisted walking are unknown. This study investigated the interaction effects of exoskeleton timing and power on gait variability. Ten healthy participants walked on a treadmill with bilateral ankle-foot exoskeletons under ten conditions with different timing (varied from 36% to 54% of the stride) and power (varied from 0.2 to 0.5 W∙kg-1) combinations. We used the largest Lyapunov exponent (LyE) and maximum Floquet multiplier (FM) to evaluate the stride-to-stride fluctuations of the kinematic time series. We found the lowest LyE at the ankle and a significant reduction versus powered-off with exoskeleton power (summed for both legs) of 0.45 W∙kg-1 and actuation timing at 48% of the stride cycle. At the knee, a significant positive effect of power and a negative interaction effect of power and timing were found for LyE. We found significant positive interaction effects of the square of timing and power for LyE at the knee and hip joints. In contrast, the FM at the ankle increased with increasing power and later timing. We found a significant negative effect of power and a positive interaction effect of power and timing for FM at the knee and no significant effects of any of the exoskeleton parameters for FM at the hip. The ability of the exoskeleton to reduce the LyE at the ankle joint offers new possibilities in terms of altering gait variability, which could have applications for using exoskeletons as rehabilitation devices. Further efforts could examine if it is possible to simultaneously reduce the LyE and FM at one or more lower limb joints

    Lower-Limb-Assisting Robotic Exoskeleton Reduces Energy Consumption in Healthy Young Persons during Stair Climbing

    Get PDF
    Many robotic exoskeletons for lower limb assistance aid walking by reducing energy costs. However, investigations examining stair-climbing assistance have remained limited, generally evaluating reduced activation of related muscles. This study sought to investigate how climbing assistance by a robotic exoskeleton affects energy consumption. Ten healthy young participants wearing a robotic exoskeleton that assists flexion and extension of hip and knee joints walked up nine flights of stairs twice at a self-selected speed with and without stair-climbing assistance. Metabolic cost was assessed by measuring oxygen consumption, heart rate, and the time to climb each flight of stairs. Net oxygen cost (NOC) and total heart beats (THB) were used as measures of metabolic cost, accounting for different climbing speeds. Stair-climbing assistance reduced NOC and THB by 9.3% (P < 0.001) and 6.9% (P = 0.003), respectively, without affecting climbing speed. Despite lack of individual optimization, assistive joint torque applied to the hip and knee joints reduced metabolic cost and cardiovascular burden of stair climbing in healthy young males. These results may be used to improve methods for stair ascent assistance.ope

    Environment-based Assistance Modulation for a Hip Exosuit via Computer Vision

    Get PDF
    Just like in humans vision plays a fundamental role in guiding adaptive locomotion, when designing the control strategy for a walking assistive technology, Computer Vision may bring substantial improvements when performing an environment-based assistance modulation. In this work, we developed a hip exosuit controller able to distinguish among three different walking terrains through the use of an RGB camera and to adapt the assistance accordingly. The system was tested with seven healthy participants walking throughout an overground path comprising of staircases and level ground. Subjects performed the task with the exosuit disabled (Exo Off), constant assistance profile (Vision Off ), and with assistance modulation (Vision On). Our results showed that the controller was able to promptly classify in real-time the path in front of the user with an overall accuracy per class above the 85%, and to perform assistance modulation accordingly. Evaluation related to the effects on the user showed that Vision On was able to outperform the other two conditions: we obtained significantly higher metabolic savings than Exo Off, with a peak of about -20% when climbing up the staircase and about -16% in the overall path, and than Vision Off when ascending or descending stairs. Such advancements in the field may yield to a step forward for the exploitation of lightweight walking assistive technologies in real-life scenarios

    Altering gait variability with an ankle exoskeleton

    Get PDF
    Exoskeletons can influence human gait. A healthy gait is characterized by a certain amount of variability compared to a non-healthy gait that has more inherent variability; however which exoskeleton assistance parameters are necessary to avoid increasing gait variability or to potentially lower gait variability below that of unassisted walking are unknown. This study investigated the interaction effects of exoskeleton timing and power on gait variability. Ten healthy participants walked on a treadmill with bilateral ankle-foot exoskeletons under ten conditions with different timing (varied from 36% to 54% of the stride) and power (varied from 0.2 to 0.5 W∙kg-1) combinations. We used the largest Lyapunov exponent (LyE) and maximum Floquet multiplier (FM) to evaluate the stride-to-stride fluctuations of the kinematic time series. We found the lowest LyE at the ankle and a significant reduction versus powered-off with exoskeleton power (summed for both legs) of 0.45 W∙kg-1 and actuation timing at 48% of the stride cycle. At the knee, a significant positive effect of power and a negative interaction effect of power and timing were found for LyE. We found significant positive interaction effects of the square of timing and power for LyE at the knee and hip joints. In contrast, the FM at the ankle increased with increasing power and later timing. We found a significant negative effect of power and a positive interaction effect of power and timing for FM at the knee and no significant effects of any of the exoskeleton parameters for FM at the hip. The ability of the exoskeleton to reduce the LyE at the ankle joint offers new possibilities in terms of altering gait variability, which could have applications for using exoskeletons as rehabilitation devices. Further efforts could examine if it is possible to simultaneously reduce the LyE and FM at one or more lower limb joints

    JNER at 15 years: analysis of the state of neuroengineering and rehabilitation.

    Get PDF
    On JNER's 15th anniversary, this editorial analyzes the state of the field of neuroengineering and rehabilitation. I first discuss some ways that the nature of neurorehabilitation research has evolved in the past 15 years based on my perspective as editor-in-chief of JNER and a researcher in the field. I highlight increasing reliance on advanced technologies, improved rigor and openness of research, and three, related, new paradigms - wearable devices, the Cybathlon competition, and human augmentation studies - indicators that neurorehabilitation is squarely in the age of wearability. Then, I briefly speculate on how the field might make progress going forward, highlighting the need for new models of training and learning driven by big data, better personalization and targeting, and an increase in the quantity and quality of usability and uptake studies to improve translation

    Exoskeleton assistance symmetry matters : unilateral assistance reduces metabolic cost, but relatively less than bilateral assistance

    Get PDF
    Background: Many gait impairments are characterized by asymmetry and result in reduced mobility. Exoskeletons could be useful for restoring gait symmetry by assisting only one leg. However, we still have limited understanding of the effects of unilateral exoskeleton assistance. Our aim was to compare the effects of unilateral and bilateral assistance using a within-subject study design. Methods: Eleven participants walked in different exoskeleton conditions. In the Unilateral conditions, only one leg was assisted. In Bilateral Matched Total Work, half of the assistance from the Unilateral conditions was applied to both legs such that the bilateral sum was equal to that of the Unilateral conditions. In Bilateral Matched Work Per Leg, the same assistance as in the Unilateral conditions was provided to both legs such that the bilateral sum was the double of that of the Unilateral conditions. In the Powered-Off condition, no assistance was provided. We measured metabolic energy consumption, exoskeleton mechanics and kinematics. Results: On average, the Unilateral, Bilateral Matched Total Work and Bilateral Matched Work Per Leg conditions reduced the metabolic rate by 7, 11 and 15%, respectively, compared with the Powered-Off condition. A possible explanation for why the Unilateral conditions effectively reduced the metabolic rate could be that they caused only very little asymmetry in gait biomechanics, except at the ankle and in the horizontal center-of-mass velocity. We found the highest ratio of metabolic rate reduction versus positive work assistance with bilateral assistance and low work per leg ( Bilateral Matched Total Work). Statistical analysis indicated that assistance symmetry and assistance per leg are more important than the bilateral summed assistance for reducing the metabolic rate of walking. Conclusions: These data bridge the gap between conclusions from studies with unilateral and bilateral exoskeletons and inform how unilateral assistance can be used to influence gait parameters, such as center-of-mass velocity

    Environment-based Assistance Modulation for a Hip Exosuit via Computer Vision

    Get PDF
    Just like in humans vision plays a fundamental role in guiding adaptive locomotion, when designing the control strategy for a walking assistive technology, Computer Vision may bring substantial improvements when performing an environment-based assistance modulation. In this work, we developed a hip exosuit controller able to distinguish among three different walking terrains through the use of an RGB camera and to adapt the assistance accordingly. The system was tested with seven healthy participants walking throughout an overground path comprising of staircases and level ground. Subjects performed the task with the exosuit disabled (Exo Off), constant assistance profile (Vision Off ), and with assistance modulation (Vision On). Our results showed that the controller was able to promptly classify in real-time the path in front of the user with an overall accuracy per class above the 85%, and to perform assistance modulation accordingly. Evaluation related to the effects on the user showed that Vision On was able to outperform the other two conditions: we obtained significantly higher metabolic savings than Exo Off, with a peak of about -20% when climbing up the staircase and about -16% in the overall path, and than Vision Off when ascending or descending stairs. Such advancements in the field may yield to a step forward for the exploitation of lightweight walking assistive technologies in real-life scenarios
    corecore