755 research outputs found

    An instrumentation system for the measurement and display of the dynamic force distribution under the foot during locomotion

    Get PDF
    Bibliography: pages 81-83.The clinical assessment of the weight bearing foot during locomotion is normally based on subjective judgement rather than on quantitative measurement. The techniques which have been proposed for recording the dynamic forces acting on the foot are either too complex for clinical practise or there is difficulty in relating the measured force distribution to the physical surface of the foot. The system that has been developed measures the vertical foot/ground forces during gait and immediately displays the data in a manner which can be readily assimilated. The instrumentation system consists of a segmented force plate constructed from 16 transparent beams mounted so that the total load as well as the centre of pressure on any beam can be ascertained. When the foot contacts the plate, its plantar surface is photographed through the transparent force plate by a television camera while a second television camera photographs a lateral aspect of the legs and feet. A composite video display is then generated consisting of (i) a lateral view of the legs and feet (ii) a view of the plantar surface of the planted foot with centre of pressure lines superimposed (iii) a bar chart display of the load carried by each beam. The system output is recorded on a video tape recorder which has a stop motion facility. This enables a frame by frame analysis to be made subsequently and selected stills to be photographed as a permanent record. Three series of photographs are presented which clearly show the differences between normal and abnormal gait

    An Implantable Low Pressure, Low Drift, Dual BioPressure Sensor and In-Vivo Calibration Methods Thereof

    Get PDF
    The human body’s intracranial pressure (ICP) is a critical component in sustaining healthy blood flow to the brain while allowing adequate volume for brain tissue within the rigid structures of the cranium. Disruptions in the body’s autoregulation of intracranial pressure are often caused by hemorrhage, tumors, edema, or excess cerebral spinal fluid resulting in treatments that are estimated to globally cost up to approximately five billion dollars annually. A critical element in the contemporary management of acute head injury, intracranial hemorrhage, stroke, or other conditions resulting in intracranial hypertension, is the real-time monitoring of ICP. Currently, such mainstream clinical monitoring can only take place short-term within an acute care hospital. The monitoring is prone to measurement drift and is comprised of externally tethered pressure sensors that are temporarily implanted into the brain, thus carrying a significant risk of infection. To date, reliable, low drift, completely internalized, long-term ICP monitoring devices remain elusive. The successful development of such a device would not only be safer and more reliable in the short-term but would expand the use of ICP monitoring for the management of chronic intracranial hypertension and enable further clinical research into these disorders. The research herein reviews the current challenges of existing ICP monitoring systems, develops a new novel sensing technology, and evaluates the same for potentially facilitating long-term implantable ICP sensing. Based upon the findings of this research, this dissertation proposes and evaluates a dual matched-die piezo-resistive strain sensing device, with a novel in-vivo calibration system and method thereof, for application to long-term implantable ICP sensing

    Continuous-time acquisition of biosignals using a charge-based ADC topology

    Get PDF
    This paper investigates continuous-time (CT) signal acquisition as an activity-dependent and nonuniform sampling alternative to conventional fixed-rate digitisation. We demonstrate the applicability to biosignal representation by quantifying the achievable bandwidth saving by nonuniform quantisation to commonly recorded biological signal fragments allowing a compression ratio of ≈5 and 26 when applied to electrocardiogram and extracellular action potential signals, respectively. We describe several desirable properties of CT sampling, including bandwidth reduction, elimination/reduction of quantisation error, and describe its impact on aliasing. This is followed by demonstration of a resource-efficient hardware implementation. We propose a novel circuit topology for a charge-based CT analogue-to-digital converter that has been optimized for the acquisition of neural signals. This has been implemented in a commercially available 0.35 ÎŒm CMOS technology occupying a compact footprint of 0.12 mm 2 . Silicon verified measurements demonstrate an 8-bit resolution and a 4 kHz bandwidth with static power consumption of 3.75 ÎŒW from a 1.5 V supply. The dynamic power dissipation is completely activity-dependent, requiring 1.39 pJ energy per conversion

    Fibre segment interferometry using code-division multiplexed optical signal processing for strain sensing applications

    Get PDF
    A novel optical signal processing scheme for multiplexing fibre segment interferometers is proposed. The continuous-wave, homodyne technique combines code-division multiplexing with single-sideband modulation. It uses only one electro-optic phase modulator to achieve both range separation and quadrature interferometric phase measurement. This scheme is applied to fibre segment interferometry, where a number of long-gauge length interferometric fibre sensors are formed by subtracting pairs of signals from equidistantly placed, weak back reflectors. In this work we give a detailed account of the signal processing involved and, in particular, explore aspects such as electronic bandwidth requirements, noise, crosstalk and linearity, which are important design considerations. A signal bandwidth of ±20 kHz permits the resolution of phase change rates of 2.5 × 104 rad s-1 for each of the four 16.5 m long segments in our setup. We show that dynamic strain resolutions below 0.2 nanostrain Hz-0.5 at 2 m sensor gauge length are achievable, even with an inexpensive diode laser. When used in applications that require only relative strain change measurements, this scheme compares well to more established techniques and can provide high-fidelity yet cost-effective measurements

    NASA Tech Briefs Index, 1977, volume 2, numbers 1-4

    Get PDF
    Announcements of new technology derived from the research and development activities of NASA are presented. Abstracts, and indexes for subject, personal author, originating center, and Tech Brief number are presented for 1977

    Southwest Research Institute assistance to NASA in biomedical areas of the technology utilization program

    Get PDF
    The activities are reported of the NASA Biomedical Applications Team at Southwest Research Institute between 25 August, 1972 and 15 November, 1973. The program background and methodology are discussed along with the technology applications, and biomedical community impacts

    Une plate-forme sans fil pour electrochimique spectroscopie d'impédance

    Get PDF
    Avec l’émergence soutenue de capteurs et de dispositifs Ă©lectrochimiques innovants, la spectroscopie d'impĂ©dance Ă©lectrochimique est devenue l'un des outils les plus importants pour la caractĂ©risation et la modĂ©lisation de la matiĂšre ionique et de l'interfaçage des capteurs. La capacitĂ© de dĂ©tecter automatiquement, Ă  l’aide de dispositifs Ă©lectrochimiques peu couteux, les caractĂ©ristiques physiques et chimiques de la matiĂšre ionique ouvre une gamme d’application trĂšs variĂ©e pour la comprĂ©hension et l’optimisation des procĂ©dĂ©s ou interviennent les processus Ă©lectrochimiques. Cette thĂšse dĂ©crit le dĂ©veloppement d’une plate-forme microĂ©lectronique miniaturisĂ©e, connectĂ©e, multiplexĂ©e, et Ă  faible coĂ»t pour la spectroscopie d'impĂ©dance diĂ©lectrique (SID) conçue pour les mesures Ă©lectrochimiques in-situ et adaptĂ©e aux architectures de rĂ©seau sans fil. La plate-forme dĂ©veloppĂ©e durant ce travail de maitrise a Ă©tĂ© testĂ©e et validĂ©e au sein d’une maille ZigBee et a Ă©tĂ© en mesure d'interfacer jusqu'Ă  trois capteurs SID en mĂȘme temps et de relayer l'information Ă  travers le net Zigbee pour l'analyse de donnĂ©es et le stockage. Le systĂšme a Ă©tĂ© construit Ă  partir de composants microĂ©lectroniques disponibles commercialement et bĂ©nĂ©ficie des avantages d'une calibration systĂšme on-the-fly qui effectue la calibration du capteur de maniĂšre aisĂ©e. Dans ce mĂ©moire de maitrise, nous rapportons la modĂ©lisation et la caractĂ©risation de senseurs Ă©lectrochimiques de nitrate; notamment nous dĂ©crivons la conception microĂ©lectronique, la rĂ©ponse d'impĂ©dance de Nyquist, la sensibilitĂ© et la prĂ©cision de la mesure Ă©lectrochimique, et les rĂ©sultats de tests de la plate-forme pour les applications de spectroscopie d'impĂ©dance relatives Ă  la dĂ©tection du nitrate, de la dĂ©tection de la qualitĂ© de l'eau, et des senseurs tactiles.The emergence of the various applications of electrochemical sensors and devices, electrochemical impedance spectroscopy became one of the most important tools for characterizing and modeling of the material and interfacing the sensors. The ability to sense in an automatic manner enables a wide variety of processes to be better understood and optimized cost-effectively. This thesis describes the development of a low-cost, miniaturized, multiplexed, and connected platform for dielectric impedance spectroscopy (DIS) designed for in-situ measurements and adapted to wireless network architectures. The platform has been tested and used as a DIS sensor node on a ZigBee mesh and was able to interface up to three DIS sensors at the same time and relay the information through the Zigbee net for data analysis and storage. The system was built from commercial microelectronics components and benefits from an on-the-fly calibration system that makes sensor calibration easy. The thesis reports characterizing and modeling of two electro-chemical devices (i.e. nitrate sensor and optically-transparent electrically-conductive glasses) and also describes the microelectronics design, the Nyquist impedance response, the measurement sensitivity and accuracy, and the testing of the platform for in-situ dielectric impedance spectroscopy applications pertaining to fertilizer sensing, water quality sensing, and touch sensing

    NASA Tech Briefs, September 1990

    Get PDF
    Topics covered include: New Product Ideas; NASA TU Services; Electronic Components and Circuits; Electronic Systems; Physical Sciences; Materials; Computer Programs; Mechanics; Machinery; Fabrication Technology; Mathematics and Information Sciences; Life Sciences

    Low Voltage Low Power Analogue Circuits Design

    Get PDF
    DisertačnĂ­ prĂĄce je zaměƙena na vĂœzkum nejbÄ›ĆŸnějĆĄĂ­ch metod, kterĂ© se vyuĆŸĂ­vajĂ­ pƙi nĂĄvrhu analogovĂœch obvodĆŻ s vyuĆŸitĂ­ nĂ­zkonapěƄovĂœch (LV) a nĂ­zkopƙíkonovĂœch (LP) struktur. Tyto LV LP obvody mohou bĂœt vytvoƙeny dĂ­ky vyspělĂœm technologiĂ­m nebo takĂ© vyuĆŸitĂ­m pokročilĂœch technik nĂĄvrhu. DisertačnĂ­ prĂĄce se zabĂœvĂĄ prĂĄvě pokročilĂœmi technikami nĂĄvrhu, pƙedevĆĄĂ­m pak nekonvenčnĂ­mi. Mezi tyto techniky patƙí vyuĆŸitĂ­ prvkĆŻ s ƙízenĂœm substrĂĄtem (bulk-driven - BD), s plovoucĂ­m hradlem (floating-gate - FG), s kvazi plovoucĂ­m hradlem (quasi-floating-gate - QFG), s ƙízenĂœm substrĂĄtem s plovoucĂ­m hradlem (bulk-driven floating-gate - BD-FG) a s ƙízenĂœm substrĂĄtem s kvazi plovoucĂ­m hradlem (quasi-floating-gate - BD-QFG). PrĂĄce je takĂ© orientovĂĄna na moĆŸnĂ© zpĆŻsoby implementace znĂĄmĂœch a modernĂ­ch aktivnĂ­ch prvkĆŻ pracujĂ­cĂ­ch v napěƄovĂ©m, proudovĂ©m nebo mix-mĂłdu. Mezi tyto prvky lze začlenit zesilovače typu OTA (operational transconductance amplifier), CCII (second generation current conveyor), FB-CCII (fully-differential second generation current conveyor), FB-DDA (fully-balanced differential difference amplifier), VDTA (voltage differencing transconductance amplifier), CC-CDBA (current-controlled current differencing buffered amplifier) a CFOA (current feedback operational amplifier). Za Ășčelem potvrzenĂ­ funkčnosti a chovĂĄnĂ­ vĂœĆĄe zmĂ­něnĂœch struktur a prvkĆŻ byly vytvoƙeny pƙíklady aplikacĂ­, kterĂ© simulujĂ­ usměrƈovacĂ­ a induktančnĂ­ vlastnosti diody, dĂĄle pak filtry dolnĂ­ propusti, pĂĄsmovĂ© propusti a takĂ© univerzĂĄlnĂ­ filtry. VĆĄechny aktivnĂ­ prvky a pƙíklady aplikacĂ­ byly ověƙeny pomocĂ­ PSpice simulacĂ­ s vyuĆŸitĂ­m parametrĆŻ technologie 0,18 m TSMC CMOS. Pro ilustraci pƙesnĂ©ho a ĂșčinnĂ©ho chovĂĄnĂ­ struktur je v disertačnĂ­ prĂĄci zahrnuto velkĂ© mnoĆŸstvĂ­ simulačnĂ­ch vĂœsledkĆŻ.The dissertation thesis is aiming at examining the most common methods adopted by analog circuits' designers in order to achieve low voltage (LV) low power (LP) configurations. The capability of LV LP operation could be achieved either by developed technologies or by design techniques. The thesis is concentrating upon design techniques, especially the non–conventional ones which are bulk–driven (BD), floating–gate (FG), quasi–floating–gate (QFG), bulk–driven floating–gate (BD–FG) and bulk–driven quasi–floating–gate (BD–QFG) techniques. The thesis also looks at ways of implementing structures of well–known and modern active elements operating in voltage–, current–, and mixed–mode such as operational transconductance amplifier (OTA), second generation current conveyor (CCII), fully–differential second generation current conveyor (FB–CCII), fully–balanced differential difference amplifier (FB–DDA), voltage differencing transconductance amplifier (VDTA), current–controlled current differencing buffered amplifier (CC–CDBA) and current feedback operational amplifier (CFOA). In order to confirm the functionality and behavior of these configurations and elements, they have been utilized in application examples such as diode–less rectifier and inductance simulations, as well as low–pass, band–pass and universal filters. All active elements and application examples have been verified by PSpice simulator using the 0.18 m TSMC CMOS parameters. Sufficient numbers of simulated plots are included in this thesis to illustrate the precise and strong behavior of structures.
    • 

    corecore