6 research outputs found

    Low Complexity All-Pass Based Polyphase Decimation Filters for ECG Monitoring

    Get PDF
    This paper presents a low complexity high efficiency decimation filter which can be employed in EletroCardioGram (ECG) acquisition systems. The decimation filter with a decimation ratio of 128 works along with a third order sigma delta modulator. It is designed in four stages to reduce cost and power consumption. The work reported here provides an efficient approach for the decimation process for high resolution biomedical data conversion applications by employing low complexity two-path all-pass based decimation filters. The performance of the proposed decimation chain was validated by using the MIT-BIH arrhythmia database and comparative simulations were conducted with the state of the art

    Two-Path All-pass Based Half-Band Infinite Impulse Response Decimation Filters and the Effects of Their Non-Linear Phase Response on ECG Signal Acquisition

    Get PDF
    This paper is based on the novel use of a very high fidelity decimation filter chain for Electrocardiogram (ECG) signal acquisition and data conversion. The multiplier-free and multi-stage structure of the proposed filters lower the power dissipation while minimizing the circuit area which are crucial design constraints to the wireless noninvasive wearable health monitoring products due to the scarce operational resources in their electronic implementation. The decimation ratio of the presented filter is 128, working in tandem with a 1-bit 3rd order Sigma Delta (ΣΔ) modulator which achieves 0.04 dB passband ripples and -74 dB stopband attenuation. The work reported here investigates the non-linear phase effects of the proposed decimation filters on the ECG signal by carrying out a comparative study after phase correction. It concludes that the enhanced phase linearity is not crucial for ECG acquisition and data conversion applications since the signal distortion of the acquired signal, due to phase non-linearity, is insignificant for both original and phase compensated filters. To the best of the authors’ knowledge, being free of signal distortion is essential as this might lead to misdiagnosis as stated in the state of the art. This article demonstrates that with their minimal power consumption and minimal signal distortion features, the proposed decimation filters can effectively be employed in biosignal data processing units

    An ultra-low power ECG acquisition and monitoring ASIC system for WBAN applications

    No full text
    This paper proposes a power and area efficient electrocardiogram (ECG) acquisition and signal processing application sensor node for wireless body area networks (WBAN). This sensor node can accurately record and detect the QRS peaks of ECG waveform with high-frequency noise suppression. The proposed system is implemented in 0.18-μm complementary metal-oxide-semiconductor technology with two chips: analog front end integrated circuit (IC) and digital application specific integrated circuit (ASIC), where the analog IC consumes only 79.6 μW with area of 4.25 mm2 and digital ASIC consumes 9 μW at 32 kHz with 1.2 mm2. Therefore, this ECG sensor node is convenient for long-term monitoring of cardiovascular condition of patients, and is very suitable for on-body WBAN applications

    Congestion control mechanism for sensor-cloud Infrastructure

    Full text link
     This thesis has developed a sensor-Cloud system that integrates WBANs with Cloud computing to enable real-time sensor data collection, storage, processing, sharing and management. As the main contribution of this study, a congestion detection and control protocol is proposed to ensure acceptable data flows are maintained during the network lifetime

    Low Power Circuits for Smart Flexible ECG Sensors

    Get PDF
    Cardiovascular diseases (CVDs) are the world leading cause of death. In-home heart condition monitoring effectively reduced the CVD patient hospitalization rate. Flexible electrocardiogram (ECG) sensor provides an affordable, convenient and comfortable in-home monitoring solution. The three critical building blocks of the ECG sensor i.e., analog frontend (AFE), QRS detector, and cardiac arrhythmia classifier (CAC), are studied in this research. A fully differential difference amplifier (FDDA) based AFE that employs DC-coupled input stage increases the input impedance and improves CMRR. A parasitic capacitor reuse technique is proposed to improve the noise/area efficiency and CMRR. An on-body DC bias scheme is introduced to deal with the input DC offset. Implemented in 0.35m CMOS process with an area of 0.405mm2, the proposed AFE consumes 0.9W at 1.8V and shows excellent noise effective factor of 2.55, and CMRR of 76dB. Experiment shows the proposed AFE not only picks up clean ECG signal with electrodes placed as close as 2cm under both resting and walking conditions, but also obtains the distinct -wave after eye blink from EEG recording. A personalized QRS detection algorithm is proposed to achieve an average positive prediction rate of 99.39% and sensitivity rate of 99.21%. The user-specific template avoids the complicate models and parameters used in existing algorithms while covers most situations for practical applications. The detection is based on the comparison of the correlation coefficient of the user-specific template with the ECG segment under detection. The proposed one-target clustering reduced the required loops. A continuous-in-time discrete-in-amplitude (CTDA) artificial neural network (ANN) based CAC is proposed for the smart ECG sensor. The proposed CAC achieves over 98% classification accuracy for 4 types of beats defined by AAMI (Association for the Advancement of Medical Instrumentation). The CTDA scheme significantly reduces the input sample numbers and simplifies the sample representation to one bit. Thus, the number of arithmetic operations and the ANN structure are greatly simplified. The proposed CAC is verified by FPGA and implemented in 0.18m CMOS process. Simulation results show it can operate at clock frequencies from 10KHz to 50MHz. Average power for the patient with 75bpm heart rate is 13.34W

    Hardware/Software Co-Design of Ultra-Low Power Biomedical Monitors

    Get PDF
    Ongoing changes in world demographics and the prevalence of unhealthy lifestyles are imposing a paradigm shift in healthcare delivery. Nowadays, chronic ailments such as cardiovascular diseases, hypertension and diabetes, represent the most common causes of death according to the World Health Organization. It is estimated that 63% of deaths worldwide are directly or indirectly related to these non-communicable diseases (NCDs), and by 2030 it is predicted that the health delivery cost will reach an amount comparable to 75% of the current GDP. In this context, technologies based on Wireless Sensor Nodes (WSNs) effectively alleviate this burden enabling the conception of wearable biomedical monitors composed of one or several devices connected through a Wireless Body Sensor Network (WBSN). Energy efficiency is of paramount importance for these devices, which must operate for prolonged periods of time with a single battery charge. In this thesis I propose a set of hardware/software co-design techniques to drastically increase the energy efficiency of bio-medical monitors. To this end, I jointly explore different alternatives to reduce the required computational effort at the software level while optimizing the power consumption of the processing hardware by employing ultra-low power multi-core architectures that exploit DSP application characteristics. First, at the sensor level, I study the utilization of a heartbeat classifier to perform selective advanced DSP on state-of-the-art ECG bio-medical monitors. To this end, I developed a framework to design and train real-time, lightweight heartbeat neuro-fuzzy classifiers, detail- ing the required optimizations to efficiently execute them on a resource-constrained platform. Then, at the network level I propose a more complex transmission-aware WBSN for activity monitoring that provides different tradeoffs between classification accuracy and transmission volume. In this work, I study the combination of a minimal set of WSNs with a smartphone, and propose two classification schemes that trade accuracy for transmission volume. The proposed method can achieve accuracies ranging from 88% to 97% and can save up to 86% of wireless transmissions, outperforming the state-of-the-art alternatives. Second, I propose a synchronization-based low-power multi-core architecture for bio-signal processing. I introduce a hardware/software synchronization mechanism that allows to achieve high energy efficiency while parallelizing the execution of multi-channel DSP applications. Then, I generalize the methodology to support bio-signal processing applications with an arbitrarily high degree of parallelism. Due to the benefits of SIMD execution and software pipelining, the architecture can reduce its power consumption by up 38% when compared to an equivalent low-power single-core alternative. Finally, I focused on the optimization of the multi-core memory subsystem, which is the major contributor to the overall system power consumption. First I considered a hybrid memory subsystem featuring a small reliable partition that can operate at ultra-low voltage enabling low-power buffering of data and obtaining up to 50% energy savings. Second, I explore a two-level memory hierarchy based on non-volatile memories (NVM) that allows for aggressive fine-grained power gating enabled by emerging low-power NVM technologies and monolithic 3D integration. Experimental results show that, by adopting this memory hierarchy, power consumption can be reduced by 5.42x in the DSP stage