1,832 research outputs found

    Fast Adaptive Robust Differentiator Based Robust-Adaptive Control of Grid-Tied Inverters with a New L Filter Design Method

    Get PDF
    In this research, a new nonlinear and adaptive state feedback controller with a fast-adaptive robust differentiator is presented for grid-tied inverters. All parameters and external disturbances are taken as uncertain in the design of the proposed controller without the disadvantages of singularity and over-parameterization. A robust differentiator based on the second order sliding mode is also developed with a fast-adaptive structure to be able to consider the time derivative of the virtual control input. Unlike the conventional backstepping, the proposed differentiator overcomes the problem of explosion of complexity. In the closed-loop control system, the three phase source currents and direct current (DC) bus voltage are assumed to be available for feedback. Using the Lyapunov stability theory, it is proven that the overall control system has the global asymptotic stability. In addition, a new simple L filter design method based on the total harmonic distortion approach is also proposed. Simulations and experimental results show that the proposed controller assurances drive the tracking errors to zero with better performance, and it is robust against all uncertainties. Moreover, the proposed L filter design method matches the total harmonic distortion (THD) aim in the design with the experimental result

    Voltage Regulation of Boost Converter using Observer based Sliding Mode Controller

    Get PDF
    This study dealt with output voltage regulation of boost converter using observer based sliding mode controller comprises of adaptive PI sliding surface. Observer was designed to estimate the inductor current value, such that no sensor was required as a feedback. Adaptive PI sliding surface was constructed from the difference between estimated inductor current and its reference value. The stability of proposed method was ensured by using Lyapunov direct method. To test the system performance, numerical simulation was conducted. The result indicated that the integral absolute error value of proposed method was 0.19, which was 7 times less than sliding mode with PI sliding surface. Consequently, the proposed method was able to estimate accurately the inductor value, track the reference voltage perfectly, and show its robustness against parameter variations

    A High-Gain Observer-Based Adaptive Super-Twisting Algorithm for DC-Link Voltage Control of NPC Converters

    Get PDF
    Acting as an interface between the grid and many energy systems, the active front-end (AFE) has been widely used in a large variety of industrial applications. In this paper, in order to ensure the fast dynamic performance and good disturbance rejection ability of the AFE, a high-gain observer (HGO) plus adaptive super-twisting algorithm (STA) for the three-level neutral-point-clamped (NPC) converter is proposed. Comparing with the conventional PI control strategy, the proposed controller implements the adaptive STA in the voltage regulator to provide a faster transient response. The gains of the adaptive STA keep varying according to the rules being reduced in steady state but increasing in transient conditions. Therefore, the chattering phenomenon is mitigated and the dynamic response is guaranteed. Additionally, to undermine the impact of external disturbances on the dc-link voltage, a high-efficiency HGO is designed in the voltage regulation loop to reject it. Experimental results based on a three-level NPC prototype are given and compared with the conventional PI method to validate the fast dynamic performance and high disturbance rejection ability of the proposed approach.National Key R&D Program of China SQ2019YFB130028National Natural Science Foundation of China 61525303National Natural Science Foundation of China 41772377National Natural Science Foundation of China 61673130Self-Planned Task of State Key Laboratory of Robotics and System (HIT) SKLRS201806BMinisterio de Economía y Competitividad TEC2016-78430-RJunta de Andalucía P18-RT-1340Fondo de Investigación Nacional de Qatar NPRP 9-310-2-13

    Sliding Mode Control

    Get PDF
    The main objective of this monograph is to present a broad range of well worked out, recent application studies as well as theoretical contributions in the field of sliding mode control system analysis and design. The contributions presented here include new theoretical developments as well as successful applications of variable structure controllers primarily in the field of power electronics, electric drives and motion steering systems. They enrich the current state of the art, and motivate and encourage new ideas and solutions in the sliding mode control area

    An enhanced DC-link voltage response for wind-driven doubly fed induction generator using adaptive fuzzy extended state observer and sliding mode control

    Get PDF
    This paper presents an enhancement method to improve the performance of the DC-link voltage loop regulation in a Doubly-Fed Induction Generator (DFIG)- based wind energy converter. An intelligent, combined control approach based on a metaheuristics-tuned Second-Order Sliding Mode (SOSM) controller and an adaptive fuzzy-scheduled Extended State Observer (ESO) is proposed and successfully applied. The proposed fuzzy gains-scheduling mechanism is performed to adaptively tune and update the bandwidth of the ESO while disturbances occur. Besides common time-domain performance indexes, bounded limitations on the effective parameters of the designed Super Twisting (STA)-based SOSM controllers are set thanks to the Lyapunov theory and used as nonlinear constraints for the formulated hard optimization control problem. A set of advanced metaheuristics, such as Thermal Exchange Optimization (TEO), Particle Swarm Optimization (PSO), Genetic Algorithm (GA), Harmony Search Algorithm (HSA), Water Cycle Algorithm (WCA), and Grasshopper Optimization Algorithm (GOA), is considered to solve the constrained optimization problem. Demonstrative simulation results are carried out to show the superiority and effectiveness of the proposed control scheme in terms of grid disturbances rejection, closed-loop tracking performance, and robustness against the chattering phenomenon. Several comparisons to our related works, i.e., approaches based on TEO-tuned PI controller, TEO-tuned STA-SOSM controller, and STA-SOSM controller-based linear observer, are presented and discussed

    Control of power electronic interfaces in distributed generation.

    Get PDF
    Renewable energy has gained popularity as an alternative resource for electric power generation. As such, Distributed Generation (DG) is expected to open new horizons to electric power generation. Most renewable energy sources cannot be connected to the load directly. Integration of the renewable energy sources with the load has brought new challenges in terms of the system’s stability, voltage regulation and power quality issues. For example, the output power, voltage and frequency of an example wind turbine depend on the wind speed, which fluctuate over time and cannot be forecasted accurately. At the same time, the nonlinearity of residential electrical load is steadily increasing with the growing use of devices with rectifiers at their front end. This nonlinearity of the load deviates both current and voltage waveforms in the distribution feeder from their sinusoidal shape, hence increasing the Total Harmonics Distortions (THD) and polluting the grid. Advances in Power Electronic Interfaces (PEI) have increased the viability of DG systems and enhanced controllability and power transfer capability. Power electronic converter as an interface between energy sources and the grid/load has a higher degree of controllability compared to electrical machine used as the generator. This controllability can be used to not only overcome the aforementioned shortfalls of integration of renewable energy with the grid/load but also to reduce THD and improve the power quality. As a consequence, design of a sophisticated controller that can take advantage of this controllability provided by PEIs to facilitate the integration of DG with the load and generate high quality power has become of great interest. In this study a set of nonlinear controllers and observers are proposed for the control of PEIs with different DG technologies. Lyapunov stability analysis, simulation and experimental results are used to validate the effectiveness of the proposed control solution in terms of tracking objective and meeting the THD requirements of IEEE 519 and EN 50160 standards for US and European power systems, respectively

    A Review on Direct Power Control of Pulsewidth Modulation Converters

    Get PDF

    Continuous dynamic sliding mode control strategy of PWM based voltage source inverter under load variations

    Get PDF
    For closed-loop controlled DC-AC inverter system, the performance is highly influenced by load variations and online current measurement. Any variation in the load will introduce unwanted periodic error at the inverter output voltage. In addition, when the current sensor is in faulty condition, the current measurement will be imprecise and the designed feedback control law will be ineffective. In this paper, a sensorless continuous sliding mode control (SMC) scheme has been proposed to address these issues. The chattering effect due to the discontinuous switching nature of SMC has been attenuated by designing a novel boundary-based saturation function where the selection of the thickness of boundary is dependent to the PWM signal generation of the inverter. In order to remove the dependency on the current sensor, a particle swarm optimization(PSO) based modified observer is proposed to estimate the inductor current in which the observer gains are optimized using PSO by reducing the estimation errors cost function. The proposed dynamic smooth SMC algorithm has been simulated in MATLAB Simulink environment for 0.2-kVA DC-AC inverter and the results exhibit rapid dynamic response with a steady-state error of 0.4V peak-to-peak voltage under linear and nonlinear load perturbations. The total harmonic distortion (THD) is also reduced to 0.20% and 1.14% for linear and non-linear loads, respectively
    corecore