6,272 research outputs found

    Adaptive calibration algorithm for plasma glucose estimation in continuous glucose monitoring

    Full text link
    [EN] Minimally or noninvasive continuous glucose monitors estimate plasma glucose from compartments alternative to blood, and may revolutionize the management of diabetes. However, the accuracy of current devices is still poor and it may partly depend on low performance of the implemented calibration algorithm. Here, a new adaptive calibration algorithm based on a population local-model-based intercompartmental glucose dynamic model is proposed. The novelty consists in the adaptation of data normalization parameters in real time to estimate and compensate patient's sensitivity variations. Adaptation is performed to minimize mean absolute relative deviation at the calibration points with a time window forgetting strategy. Four calibrations are used: preprandial and 1.5 h postprandial at two different meals. Two databases are used for validation: 1) a 9-hCGMSGold (Medtronic, Northridge, USA) time series with paired reference glucose values from a clinical study in 17 subjects with type 1 diabetes; 2) data from 30 virtual patients (UVa simulator, Virginia, USA), where inter-and intrasubject variability of sensor's sensitivity were simulated. Results show how the adaptation of the normalization parameters improves the performance of the calibration algorithm since it counteracts sensor sensitivity variations. This improvement is more evident in one-week simulations.Manuscript received April 17, 2012; revised September 10, 2012 and January 21, 2013; accepted March 11, 2013. Date of publication March 19, 2013; date of current version May 1, 2013. This work was supported in part by the Spanish Ministry of Science and Innovation under Project DPI2010-20764-C02 and in part by the European Union under Grant FP7-PEOPLE-2009-IEF, Ref 252085. The work of F. Barcelo-Rico was supported by the Spanish Ministry of Education (FPU AP2008-02967).Barceló-Rico, F.; Diez, J.; Rossetti, P.; Vehi, J.; Bondía Company, J. (2013). Adaptive calibration algorithm for plasma glucose estimation in continuous glucose monitoring. IEEE Journal of Biomedical and Health Informatics. 17(3):530-538. https://doi.org/10.1109/JBHI.2013.2253325S53053817

    Multimodel Approaches for Plasma Glucose Estimation in Continuous Glucose Monitoring. Development of New Calibration Algorithms

    Full text link
    ABSTRACT Diabetes Mellitus (DM) embraces a group of metabolic diseases which main characteristic is the presence of high glucose levels in blood. It is one of the diseases with major social and health impact, both for its prevalence and also the consequences of the chronic complications that it implies. One of the research lines to improve the quality of life of people with diabetes is of technical focus. It involves several lines of research, including the development and improvement of devices to estimate "online" plasma glucose: continuous glucose monitoring systems (CGMS), both invasive and non-invasive. These devices estimate plasma glucose from sensor measurements from compartments alternative to blood. Current commercially available CGMS are minimally invasive and offer an estimation of plasma glucose from measurements in the interstitial fluid CGMS is a key component of the technical approach to build the artificial pancreas, aiming at closing the loop in combination with an insulin pump. Yet, the accuracy of current CGMS is still poor and it may partly depend on low performance of the implemented Calibration Algorithm (CA). In addition, the sensor-to-patient sensitivity is different between patients and also for the same patient in time. It is clear, then, that the development of new efficient calibration algorithms for CGMS is an interesting and challenging problem. The indirect measurement of plasma glucose through interstitial glucose is a main confounder of CGMS accuracy. Many components take part in the glucose transport dynamics. Indeed, physiology might suggest the existence of different local behaviors in the glucose transport process. For this reason, local modeling techniques may be the best option for the structure of the desired CA. Thus, similar input samples are represented by the same local model. The integration of all of them considering the input regions where they are valid is the final model of the whole data set. Clustering is tBarceló Rico, F. (2012). Multimodel Approaches for Plasma Glucose Estimation in Continuous Glucose Monitoring. Development of New Calibration Algorithms [Tesis doctoral no publicada]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/17173Palanci

    Continuous glucose monitoring sensors: Past, present and future algorithmic challenges

    Get PDF
    Continuous glucose monitoring (CGM) sensors are portable devices that allow measuring and visualizing the glucose concentration in real time almost continuously for several days and are provided with hypo/hyperglycemic alerts and glucose trend information. CGM sensors have revolutionized Type 1 diabetes (T1D) management, improving glucose control when used adjunctively to self-monitoring blood glucose systems. Furthermore, CGM devices have stimulated the development of applications that were impossible to create without a continuous-time glucose signal, e.g., real-time predictive alerts of hypo/hyperglycemic episodes based on the prediction of future glucose concentration, automatic basal insulin attenuation methods for hypoglycemia prevention, and the artificial pancreas. However, CGM sensors’ lack of accuracy and reliability limited their usability in the clinical practice, calling upon the academic community for the development of suitable signal processing methods to improve CGM performance. The aim of this paper is to review the past and present algorithmic challenges of CGM sensors, to show how they have been tackled by our research group, and to identify the possible future ones

    Estimating Plasma Glucose from Interstitial Glucose: The Issue of Calibration Algorithms in Commercial Continuous Glucose Monitoring Devices

    Get PDF
    Evaluation of metabolic control of diabetic people has been classically performed measuring glucose concentrations in blood samples. Due to the potential improvement it offers in diabetes care, continuous glucose monitoring (CGM) in the subcutaneous tissue is gaining popularity among both patients and physicians. However, devices for CGM measure glucose concentration in compartments other than blood, usually the interstitial space. This means that CGM need calibration against blood glucose values, and the accuracy of the estimation of blood glucose will also depend on the calibration algorithm. The complexity of the relationship between glucose dynamics in blood and the interstitial space, contrasts with the simplistic approach of calibration algorithms currently implemented in commercial CGM devices, translating in suboptimal accuracy. The present review will analyze the issue of calibration algorithms for CGM, focusing exclusively on the commercially available glucose sensors

    Modeling and Prediction in Diabetes Physiology

    Get PDF
    Diabetes is a group of metabolic diseases characterized by the inability of the organism to autonomously regulate the blood glucose levels. It requires continuing medical care to prevent acute complications and to reduce the risk of long-term complications. Inadequate glucose control is associated with damage, dysfunction and failure of various organs. The management of the disease is non trivial and demanding. With today’s standards of current diabetes care, good glucose regulation needs constant attention and decision-making by the individuals with diabetes. Empowering the patients with a decision support system would, therefore, improve their quality of life without additional burdens nor replacing human expertise. This thesis investigates the use of data-driven techniques to the purpose of glucose metabolism modeling and short-term blood-glucose predictions in Type I Diabetes Mellitus (T1DM). The goal was to use models and predictors in an advisory tool able to produce personalized short-term blood glucose predictions and on-the-spot decision making concerning the most adequate choice of insulin delivery, meal intake and exercise, to help diabetic subjects maintaining glycemia as close to normal as possible. The approaches taken to describe the glucose metabolism were discrete-time and continuous-time models on input-output form and statespace form, while the blood glucose short-term predictors, i.e., up to 120 minutes ahead, used ARX-, ARMAX- and subspace-based prediction

    Integral-based filtering of continuous glucose sensor measurements for glycaemic control in critical care

    Get PDF
    Hyperglycaemia is prevalent in critical illness and increases the risk of further complications and mortality, while tight control can reduce mortality up to 43%. Adaptive control methods are capable of highly accurate, targeted blood glucose regulation using limited numbers of manual measurements due to patient discomfort and labour intensity. Therefore, the option to obtain greater data density using emerging continuous glucose sensing devices is attractive. However, the few such systems currently available can have errors in excess of 20-30%. In contrast, typical bedside testing kits have errors of approximately 7-10%. Despite greater measurement frequency larger errors significantly impact the resulting glucose and patient specific parameter estimates, and thus the control actions determined creating an important safety and performance issue. This paper models the impact of the Continuous Glucose Monitoring System (CGMS, Medtronic, Northridge, CA) on model-based parameter identification and glucose prediction. An integral-based fitting and filtering method is developed to reduce the effect of these errors. A noise model is developed based on CGMS data reported in the literature, and is slightly conservative with a mean Clarke Error Grid (CEG) correlation of R=0.81 (range: 0.68-0.88) as compared to a reported value of R=0.82 in a critical care study. Using 17 virtual patient profiles developed from retrospective clinical data, this noise model was used to test the methods developed. Monte-Carlo simulation for each patient resulted in an average absolute one-hour glucose prediction error of 6.20% (range: 4.97-8.06%) with an average standard deviation per patient of 5.22% (range: 3.26-8.55%). Note that all the methods and results are generalisable to similar applications outside of critical care, such as less acute wards and eventually ambulatory individuals. Clinically, the results show one possible computational method for managing the larger errors encountered in emerging continuous blood glucose sensors, thus enabling their more effective use in clinical glucose regulation studies

    “Smart” Continuous Glucose Monitoring Sensors: On-Line Signal Processing Issues

    Get PDF
    The availability of continuous glucose monitoring (CGM) sensors allows development of new strategies for the treatment of diabetes. In particular, from an on-line perspective, CGM sensors can become “smart” by providing them with algorithms able to generate alerts when glucose concentration is predicted to exceed the normal range thresholds. To do so, at least four important aspects have to be considered and dealt with on-line. First, the CGM data must be accurately calibrated. Then, CGM data need to be filtered in order to enhance their signal-to-noise ratio (SNR). Thirdly, predictions of future glucose concentration should be generated with suitable modeling methodologies. Finally, generation of alerts should be done by minimizing the risk of detecting false and missing true events. For these four challenges, several techniques, with various degrees of sophistication, have been proposed in the literature and are critically reviewed in this paper

    Linear Modeling and Prediction in Diabetes Physiology

    Get PDF
    Diabetes Mellitus is a chronic disease characterized by the inability of the organism to autonomously regulate the blood glucose level due to insulin deficiency or resistance, leading to serious health damages. The therapy is essentially based on insulin injections and depends strongly on patient daily decisions, being mainly based upon empirical experience and rules of thumb. The development of a prediction engine capable of personalized on-the-spot decision making concerning the most adequate choice of insulin delivery, meal intake and exercise would therefore be a valuable initiative towards an improved management of the desease. This thesis presents work on data-driven glucose metabolism modeling and short-term, that is, up to 120 minutes, blood-glucose prediction in Type 1 Diabetes Mellitus (T1DM) subjects. In order to address model-based control for blood glucose regulation, low-order, individualized, data-driven, stable, physiological relevant models were identified from a population of 9 T1DM patients data. Model structures include: autoregressive moving average with exogenous inputs (ARMAX) models and state-space models.ARMAX multi-step-ahead predictors were estimated by means of least-squares estimation; next regularization of the autoregressive coefficients was introduced. ARMAX-based predictors and zero-order hold were computed to allow comparison.Finally, preliminary results on subspace-based multi-step-ahead multivariate predictors is presented

    Modeling, Estimation, and Feedback Techniques in Type 2 Diabetes

    Get PDF
    corecore