390 research outputs found
Three-dimensional reconstruction of stenosed coronary artery segments with assessment of the flow impedance
In this paper preliminary results of a study about the diagnostic benefits of 3D visualization and quantitation of stenosed coronary artery segments are presented. As is well known, even biplane angiographic images do not provide enough information for binary reconstruction. Therefore,a priori information about the slice to be reconstructed must be incorporated into the reconstruction algorithm. One approach is to assume a circular cross-section of the coronary artery. Hence, the diameter is estimated from the contours of the vessels in both projections. Another approach is to search for a solution of the reconstruction problem close to the previously reconstructed adjacent slice. In this paper we follow the first method based on contour information. The reconstructed coronary segment is visualized in three dimensions. Based on the obtained geometry of the obstruction the pertinent blood flow impedance is estimated on the basis of fluid dynamic principles. The results of applying the reconstruction algorithms to clinical coronary biplane exposures are presented with an indication of the assessed flow impedance
Four-dimensional imaging of thoracic target volumes in conformal radiotherapy
The goal of conformal radiotherapy (CRT) is to deliver the prescribed dose to a
volume that closely conforms to the three-dimensional (3D) target volume while the
dose to adjacent healthy tissues or organs at risk is minimized. Because the position
of the target volume can change substantially both within and between radiation
treatment fractions the fourth dimension, namely time, needs to be addressed as
well. The consideration of time in the 3D treatment process is referred to as fourdimensional
(4D) radiotherapy. Variations in the target volume position with time
are mainly due to organ motion and patient and beam set-up deviations. Changes in
the target volume position that occur within a treatment fraction are referred to as
intra-fraction variation. Respiratory and cardiac motion are the main contributors
to intra-fraction positional variations of thoracic and abdominal target volumes.
In routine clinical practice thoracic and abdominal tumors are irradiated while
the patient breathes freely. To account for target volume variations in size, shape
and position and patient and beam set-up deviations, an empirical 3D margin is
added to the clinical target volume to obtain the planning target volume (1, 2).
The 3D margin is often derived from respiratory motion measurements in patients
representative of the general population. Such a margin is not tailored to the
individual patient and will therefore be suboptimal in most cases. Alternatively,
the tumor motion in a specific patient can be determined as part of the treatment
planning procedure. Fluoroscopy is most widely used for this purpose. However,
tumors are often poorly visualized using this imaging modality. In addition,
fluoroscopic data cannot directly be related to the treatment planning computed
tomography (CT) data
Three-dimensional reconstruction of myocardial contrast perfusion from biplane cineangiograms by means of linear programming techniques
The assessment of coronary flow reserve from the instantaneous distribution of the contrast agent within the coronary vessels and myocardial muscle at the control state and at maximal flow has been limited by the superimposition of myocardial regions of interest in the two-dimensional images. To overcome these limitations, we are in the process of developing a three-dimensional (3D) reconstruction technique to compute the contrast distribution in cross sections of the myocardial muscle from two orthogonal cineangiograms. To limit the number of feasible solutions in the 3D-reconstruction space, the 3D-geometry of the endo- and epicardial boundaries of the myocardium must be determined. For the geometric reconstruction of the epicardium, the centerlines of the left coronary arterial tree are manually or automatically traced in the biplane views. Next, the bifurcations are detected automatically and matched in these two views, allowing a 3D-representation of the coronary tree. Finally, the circumference of the left ventricular myocardium in a selected cross section can be computed from the intersection points of this cross section with the 3D coronary tree using B-splines. For the geometric reconstruction of the left ventricular cavity, we envision to apply the elliptical approximation technique using the LV boundaries defined in the two orthogonal views, or by applying more complex 3D-reconstruction techniques including densitometry. The actual 3D-reconstruction of the contrast distribution in the myocardium is based on a linear programming technique (Transportation model) using cost coefficient matrices. Such a cost coefficient matrix must contain a maximum amount of a priori information, provided by a computer generated model and updated with actual data from the angiographic views. We have only begun to solve this complex problem. However, based on our first experimental results we expect that the linear programming approach with advanced cost coefficient matrices and computed model will lead to a
Reconstruction of coronary arteries from X-ray angiography: A review.
Despite continuous progress in X-ray angiography systems, X-ray coronary angiography is fundamentally limited by its 2D representation of moving coronary arterial trees, which can negatively impact assessment of coronary artery disease and guidance of percutaneous coronary intervention. To provide clinicians with 3D/3D+time information of coronary arteries, methods computing reconstructions of coronary arteries from X-ray angiography are required. Because of several aspects (e.g. cardiac and respiratory motion, type of X-ray system), reconstruction from X-ray coronary angiography has led to vast amount of research and it still remains as a challenging and dynamic research area. In this paper, we review the state-of-the-art approaches on reconstruction of high-contrast coronary arteries from X-ray angiography. We mainly focus on the theoretical features in model-based (modelling) and tomographic reconstruction of coronary arteries, and discuss the evaluation strategies. We also discuss the potential role of reconstructions in clinical decision making and interventional guidance, and highlight areas for future research
Object-Based 3-D Reconstruction of Arterial Trees from Magnetic Resonance Angiograms
By exploiting a priori knowledge of arterial shape and smoothness, subpixel accuracy reconstructions are achieved from only four noisy projection images. The method incorporates a priori knowledge of the structure of branching arteries into a natural optimality criterion that encompasses the entire arterial tree. An efficient optimization algorithm for object estimation is presented, and its performance on simulated, phantom, and in vivo magnetic resonance angiograms is demonstrated. It is shown that accurate reconstruction of bifurcations is achievable with parametric models.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/85841/1/Fessler111.pd
Three-Dimensional Motion Tracking of Coronary Arteries in Biplane Cineangiogram
International audienceA three-dimensional (3-D) method for tracking the coronary arteries through a temporal sequence of biplane X-ray angiography images is presented. A 3-D centerline model of the coronary vasculature is reconstructed from a biplane image pair at one time frame, and its motion is tracked using a coarse-to-fine hierarchy of motion models. Three-dimensional constraints on the length of the arteries and on the spatial regularity of the motion field are used to overcome limitations of classical two-dimensional vessel tracking methods, such as tracking vessels through projective occlusions. This algorithm was clinically validated in five patients by tracking the motion of the left coronary tree over one cardiac cycle. The root mean square reprojection errors were found to be submillimeter in 93% (54/58) of the image pairs. The performance of the tracking algorithm was quantified in three dimensions using a deforming vascular phantom. RMS 3-D distance errors were computed between centerline models tracked in the X-ray images and gold-standard centerline models of the phantom generated from a gated 3-D magnetic resonance image acquisition. The mean error was 0.69( 0.06) mm over eight temporal phases and four different biplane orientations
Recommended from our members
Automatic 3D Reconstruction of Coronary Artery Centerlines from Monoplane X-ray Angiogram Images
We present a new method for the fully automatic 3D reconstruction of the coronary artery centerlines, using two X-ray angiogram projection images from a single rotating monoplane acquisition system. During the first stage, the input images are smoothed using curve evolution techniques. Next, a simple yet efficient multiscale method, based on the information of the Hessian matrix, for the enhancement of the vascular structure is introduced. Hysteresis thresholding using different image quantiles, is used to threshold the arteries. This stage is followed by a thinning procedure to extract the centerlines. The resulting skeleton image is then pruned using morphological and pattern recognition techniques to remove non-vessel like structures. Finally, edge-based stereo correspondence is solved using a parallel evolutionary optimization method based on f symbiosis. The detected 2D centerlines combined with disparity map information allow the reconstruction of the 3D vessel centerlines. The proposed method has been evaluated on patient data sets for evaluation purposes
Coronary Artery Segmentation and Motion Modelling
Conventional coronary artery bypass surgery requires invasive sternotomy and the
use of a cardiopulmonary bypass, which leads to long recovery period and has high
infectious potential. Totally endoscopic coronary artery bypass (TECAB) surgery
based on image guided robotic surgical approaches have been developed to allow the
clinicians to conduct the bypass surgery off-pump with only three pin holes incisions
in the chest cavity, through which two robotic arms and one stereo endoscopic camera
are inserted. However, the restricted field of view of the stereo endoscopic images leads
to possible vessel misidentification and coronary artery mis-localization. This results
in 20-30% conversion rates from TECAB surgery to the conventional approach.
We have constructed patient-specific 3D + time coronary artery and left ventricle
motion models from preoperative 4D Computed Tomography Angiography (CTA)
scans. Through temporally and spatially aligning this model with the intraoperative
endoscopic views of the patient's beating heart, this work assists the surgeon to identify
and locate the correct coronaries during the TECAB precedures. Thus this work has
the prospect of reducing the conversion rate from TECAB to conventional coronary
bypass procedures.
This thesis mainly focus on designing segmentation and motion tracking methods
of the coronary arteries in order to build pre-operative patient-specific motion models.
Various vessel centreline extraction and lumen segmentation algorithms are presented,
including intensity based approaches, geometric model matching method and
morphology-based method. A probabilistic atlas of the coronary arteries is formed
from a group of subjects to facilitate the vascular segmentation and registration procedures.
Non-rigid registration framework based on a free-form deformation model
and multi-level multi-channel large deformation diffeomorphic metric mapping are
proposed to track the coronary motion. The methods are applied to 4D CTA images
acquired from various groups of patients and quantitatively evaluated
Dynamic Analysis of X-ray Angiography for Image-Guided Coronary Interventions
Percutaneous coronary intervention (PCI) is a minimally-invasive procedure for treating patients with coronary artery disease. PCI is typically performed with image guidance using X-ray angiograms (XA) in which coronary arter
Temporal tracking of 3D coronary arteries in projection angiograms
International audienceA method for 3D temporal tracking of a 3D coronary tree model through a sequence of biplane cineangiography images has been developed. A registration framework is formulated in which the coronary tree centerline model deforms in an external potential ¯eld de¯ned by a multiscale analysis response map computed from the angiogram images. To constrain the procedure and to improve convergence, a set of three motion models is hierarchically used: a 3D rigid-body transformation, a 3D a±ne transformation, and a 3D B-spline deformation ¯eld. This 3D motion tracking approach has signi¯cant advantages over 2D methods: (1) coherent deformation of a single 3D coronary reconstruction preserves the topology of the arterial tree; (2) constraints on arterial length and regularity, which lack meaning in 2D projection space, are directly applicable in 3D; and (3) tracking arterial segments through occlusions and crossings in the projection images is simpli¯ed with knowledge of the 3D relationship of the arteries. The method has been applied to patient data and results are presented
- …