154 research outputs found

    Joint segmentation and classification of retinal arteries/veins from fundus images

    Full text link
    Objective Automatic artery/vein (A/V) segmentation from fundus images is required to track blood vessel changes occurring with many pathologies including retinopathy and cardiovascular pathologies. One of the clinical measures that quantifies vessel changes is the arterio-venous ratio (AVR) which represents the ratio between artery and vein diameters. This measure significantly depends on the accuracy of vessel segmentation and classification into arteries and veins. This paper proposes a fast, novel method for semantic A/V segmentation combining deep learning and graph propagation. Methods A convolutional neural network (CNN) is proposed to jointly segment and classify vessels into arteries and veins. The initial CNN labeling is propagated through a graph representation of the retinal vasculature, whose nodes are defined as the vessel branches and edges are weighted by the cost of linking pairs of branches. To efficiently propagate the labels, the graph is simplified into its minimum spanning tree. Results The method achieves an accuracy of 94.8% for vessels segmentation. The A/V classification achieves a specificity of 92.9% with a sensitivity of 93.7% on the CT-DRIVE database compared to the state-of-the-art-specificity and sensitivity, both of 91.7%. Conclusion The results show that our method outperforms the leading previous works on a public dataset for A/V classification and is by far the fastest. Significance The proposed global AVR calculated on the whole fundus image using our automatic A/V segmentation method can better track vessel changes associated to diabetic retinopathy than the standard local AVR calculated only around the optic disc.Comment: Preprint accepted in Artificial Intelligence in Medicin

    3D reconstruction of the optic nerve head of a phantom eye from images obtained using a slit lamp fitted with low cost add-ons

    Get PDF
    Early detection and treatment are key in limiting vision loss from glaucoma, the second leading cause of blindness worldwide. The alteration of the optic nerve head’s (ONH) morphology, detectable early in the condition, is a key clinical indicator. The current gold standard is subjective observation through a slit lamp. If quantitative diagnostic devices to extract the topography of the ONH could be made objective and affordable, it could mean task shifting glaucoma diagnostics from specialist to primary/community care. A potentially cost-effective solution is to apply digital 3D reconstruction to stereo images obtained through a slit lamp, a mainstay of eye diagnostics, present in practically all ophthalmology and optometry practices. This works shows ONH reconstruction in an eye phantom through a common slit lamp fitted with extremely inexpensive cameras. Quantitative reconstructions, in close agreement with ground truths, were obtained

    Synthetic stereo images of the optic disc from the CORD dataset

    Get PDF
    Advancement of techniques for 3D reconstruction of the optic disc could lead to affordable objective detection of glaucoma. Applying computer stereo vision techniques to image pairs is particularly promising. More data, along with the stereo camera calibration parameters and ground truths required for validation, could aid development. This work presents a method to generate, using a virtual environment, synthetic stereo images of optic discs from images in the CORD database and obtain the corresponding stereo camera calibration parameters and ground truths. Our own reconstruction technique was tested using data created using this environment and quantitatively validated

    Automated 3-D method for the correction of axial artifacts in spectral-domain optical coherence tomography images

    Get PDF
    The 3-D spectral-domain optical coherence tomography (SD-OCT) images of the retina often do not reflect the true shape of the retina and are distorted differently along the x and y axes. In this paper, we propose a novel technique that uses thin-plate splines in two stages to estimate and correct the distinct axial artifacts in SD-OCT images. The method was quantitatively validated using nine pairs of OCT scans obtained with orthogonal fast-scanning axes, where a segmented surface was compared after both datasets had been corrected. The mean unsigned difference computed between the locations of this artifact-corrected surface after the single-spline and dual-spline correction was 23.36 ± 4.04 μm and 5.94 ± 1.09 μm, respectively, and showed a significant difference (p < 0.001 from two-tailed paired t-test). The method was also validated using depth maps constructed from stereo fundus photographs of the optic nerve head, which were compared to the flattened top surface from the OCT datasets. Significant differences (p < 0.001) were noted between the artifact-corrected datasets and the original datasets, where the mean unsigned differences computed over 30 optic-nerve-head-centered scans (in normalized units) were 0.134 ± 0.035 and 0.302 ± 0.134, respectively

    Fusion based analysis of ophthalmologic image data

    Get PDF
    summary:The paper presents an overview of image analysis activities of the Brno DAR group in the medical application area of retinal imaging. Particularly, illumination correction and SNR enhancement by registered averaging as preprocessing steps are briefly described; further mono- and multimodal registration methods developed for specific types of ophthalmological images, and methods for segmentation of optical disc, retinal vessel tree and autofluorescence areas are presented. Finally, the designed methods for neural fibre layer detection and evaluation on retinal images, utilising different combined texture analysis approaches and several types of classifiers, are shown. The results in all the areas are shortly commented on at the respective sections. In order to emphasise methodological aspects, the methods and results are ordered according to consequential phases of processing rather then divided according to individual medical applications

    Image database system for glaucoma diagnosis support

    Get PDF
    Tato práce popisuje přehled standardních a pokročilých metod používaných k diagnose glaukomu v ranném stádiu. Na základě teoretických poznatků je implementován internetově orientovaný informační systém pro oční lékaře, který má tři hlavní cíle. Prvním cílem je možnost sdílení osobních dat konkrétního pacienta bez nutnosti posílat tato data internetem. Druhým cílem je vytvořit účet pacienta založený na kompletním očním vyšetření. Posledním cílem je aplikovat algoritmus pro registraci intenzitního a barevného fundus obrazu a na jeho základě vytvořit internetově orientovanou tři-dimenzionální vizualizaci optického disku. Tato práce je součásti DAAD spolupráce mezi Ústavem Biomedicínského Inženýrství, Vysokého Učení Technického v Brně, Oční klinikou v Erlangenu a Ústavem Informačních Technologií, Friedrich-Alexander University, Erlangen-Nurnberg.This master thesis describes a conception of standard and advanced eye examination methods used for glaucoma diagnosis in its early stage. According to the theoretical knowledge, a web based information system for ophthalmologists with three main aims is implemented. The first aim is the possibility to share medical data of a concrete patient without sending his personal data through the Internet. The second aim is to create a patient account based on a complete eye examination procedure. The last aim is to improve the HRT diagnostic method with an image registration algorithm for the fundus and intensity images and create an optic nerve head web based 3D visualization. This master thesis is a part of project based on DAAD co-operation between Department of Biomedical Engineering, Brno University of Technology, Eye Clinic in Erlangen and Department of Computer Science, Friedrich-Alexander University, Erlangen-Nurnberg.

    Machine Learning Approaches for Automated Glaucoma Detection using Clinical Data and Optical Coherence Tomography Images

    Full text link
    Glaucoma is a multi-factorial, progressive blinding optic-neuropathy. A variety of factors, including genetics, vasculature, anatomy, and immune factors, are involved. Worldwide more than 80 million people are affected by glaucoma, and around 300,000 in Australia, where 50% remain undiagnosed. Untreated glaucoma can lead to blindness. Early detection by Artificial intelligence (AI) is crucial to accelerate the diagnosis process and can prevent further vision loss. Many proposed AI systems have shown promising performance for automated glaucoma detection using two-dimensional (2D) data. However, only a few studies had optimistic outcomes for glaucoma detection and staging. Moreover, the automated AI system still faces challenges in diagnosing at the clinicians’ level due to the lack of interpretability of the ML algorithms and integration of multiple clinical data. AI technology would be welcomed by doctors and patients if the "black box" notion is overcome by developing an explainable, transparent AI system with similar pathological markers used by clinicians as the sign of early detection and progression of glaucomatous damage. Therefore, the thesis aimed to develop a comprehensive AI model to detect and stage glaucoma by incorporating a variety of clinical data and utilising advanced data analysis and machine learning (ML) techniques. The research first focuses on optimising glaucoma diagnostic features by combining structural, functional, demographic, risk factor, and optical coherence tomography (OCT) features. The significant features were evaluated using statistical analysis and trained in ML algorithms to observe the detection performance. Three crucial structural ONH OCT features: cross-sectional 2D radial B-scan, 3D vascular angiography and temporal-superior-nasal-inferior-temporal (TSNIT) B-scan, were analysed and trained in explainable deep learning (DL) models for automated glaucoma prediction. The explanation behind the decision making of DL models were successfully demonstrated using the feature visualisation. The structural features or distinguished affected regions of TSNIT OCT scans were precisely localised for glaucoma patients. This is consistent with the concept of explainable DL, which refers to the idea of making the decision-making processes of DL models transparent and interpretable to humans. However, artifacts and speckle noise often result in misinterpretation of the TSNIT OCT scans. This research also developed an automated DL model to remove the artifacts and noise from the OCT scans, facilitating error-free retinal layers segmentation, accurate tissue thickness estimation and image interpretation. Moreover, to monitor and grade glaucoma severity, the visual field (VF) test is commonly followed by clinicians for treatment and management. Therefore, this research uses the functional features extracted from VF images to train ML algorithms for staging glaucoma from early to advanced/severe stages. Finally, the selected significant features were used to design and develop a comprehensive AI model to detect and grade glaucoma stages based on the data quantity and availability. In the first stage, a DL model was trained with TSNIT OCT scans, and its output was combined with significant structural and functional features and trained in ML models. The best-performed ML model achieved an area under the curve (AUC): 0.98, an accuracy of 97.2%, a sensitivity of 97.9%, and a specificity of 96.4% for detecting glaucoma. The model achieved an overall accuracy of 90.7% and an F1 score of 84.0% for classifying normal, early, moderate, and advanced-stage glaucoma. In conclusion, this thesis developed and proposed a comprehensive, evidence-based AI model that will solve the screening problem for large populations and relieve experts from manually analysing a slew of patient data and associated misinterpretation problems. Moreover, this thesis demonstrated three structural OCT features that could be added as excellent diagnostic markers for precise glaucoma diagnosis

    Digital ocular fundus imaging: a review

    Get PDF
    Ocular fundus imaging plays a key role in monitoring the health status of the human eye. Currently, a large number of imaging modalities allow the assessment and/or quantification of ocular changes from a healthy status. This review focuses on the main digital fundus imaging modality, color fundus photography, with a brief overview of complementary techniques, such as fluorescein angiography. While focusing on two-dimensional color fundus photography, the authors address the evolution from nondigital to digital imaging and its impact on diagnosis. They also compare several studies performed along the transitional path of this technology. Retinal image processing and analysis, automated disease detection and identification of the stage of diabetic retinopathy (DR) are addressed as well. The authors emphasize the problems of image segmentation, focusing on the major landmark structures of the ocular fundus: the vascular network, optic disk and the fovea. Several proposed approaches for the automatic detection of signs of disease onset and progression, such as microaneurysms, are surveyed. A thorough comparison is conducted among different studies with regard to the number of eyes/subjects, imaging modality, fundus camera used, field of view and image resolution to identify the large variation in characteristics from one study to another. Similarly, the main features of the proposed classifications and algorithms for the automatic detection of DR are compared, thereby addressing computer-aided diagnosis and computer-aided detection for use in screening programs.Fundação para a Ciência e TecnologiaFEDErPrograma COMPET

    Retinal Fundus Image Analysis for Diagnosis of Glaucoma: A Comprehensive Survey

    Full text link
    © 2016 IEEE. The rapid development of digital imaging and computer vision has increased the potential of using the image processing technologies in ophthalmology. Image processing systems are used in standard clinical practices with the development of medical diagnostic systems. The retinal images provide vital information about the health of the sensory part of the visual system. Retinal diseases, such as glaucoma, diabetic retinopathy, age-related macular degeneration, Stargardt's disease, and retinopathy of prematurity, can lead to blindness manifest as artifacts in the retinal image. An automated system can be used for offering standardized large-scale screening at a lower cost, which may reduce human errors, provide services to remote areas, as well as free from observer bias and fatigue. Treatment for retinal diseases is available; the challenge lies in finding a cost-effective approach with high sensitivity and specificity that can be applied to large populations in a timely manner to identify those who are at risk at the early stages of the disease. The progress of the glaucoma disease is very often quiet in the early stages. The number of people affected has been increasing and patients are seldom aware of the disease, which can cause delay in the treatment. A review of how computer-aided approaches may be applied in the diagnosis and staging of glaucoma is discussed here. The current status of the computer technology is reviewed, covering localization and segmentation of the optic nerve head, pixel level glaucomatic changes, diagonosis using 3-D data sets, and artificial neural networks for detecting the progression of the glaucoma disease
    corecore