4,218 research outputs found
Testing Foundations of Biological Scaling Theory Using Automated Measurements of Vascular Networks
Scientists have long sought to understand how vascular networks supply blood
and oxygen to cells throughout the body. Recent work focuses on principles that
constrain how vessel size changes through branching generations from the aorta
to capillaries and uses scaling exponents to quantify these changes. Prominent
scaling theories predict that combinations of these exponents explain how
metabolic, growth, and other biological rates vary with body size.
Nevertheless, direct measurements of individual vessel segments have been
limited because existing techniques for measuring vasculature are invasive,
time consuming, and technically difficult. We developed software that extracts
the length, radius, and connectivity of in vivo vessels from contrast-enhanced
3D Magnetic Resonance Angiography. Using data from 20 human subjects, we
calculated scaling exponents by four methods--two derived from local properties
of branching junctions and two from whole-network properties. Although these
methods are often used interchangeably in the literature, we do not find
general agreement between these methods, particularly for vessel lengths.
Measurements for length of vessels also diverge from theoretical values, but
those for radius show stronger agreement. Our results demonstrate that vascular
network models cannot ignore certain complexities of real vascular systems and
indicate the need to discover new principles regarding vessel lengths
PORTABLE MULTI-CAMERA SYSTEM: FROM FAST TUNNEL MAPPING TO SEMI-AUTOMATIC SPACE DECOMPOSITION AND CROSS-SECTION EXTRACTION
The paper outlines the first steps of a research project focused on the digitalization of underground tunnels for the mining industry. The aim is to solve the problem of rapidly, semi-automatically, efficiently, and reliably digitizing complex and meandering tunnels. A handheld multi-camera photogrammetric tool is used for the survey phase, which allows for the rapid acquisition of the image dataset needed to produce the 3D data. Moreover, since often, automatic, and fast acquisitions are not supported by easy-to-use tools to access and use the data at an operational level, a second aim of the research is to define a method able to arrange and organise the gathered data so that it would be easily accessible. The proposed approach is to compute the 3D skeleton of the surveyed environment by employing tools developed for the analysis of vascular networks in medical imagery. From the computed skeletonization of the underground tunnels, a method is proposed to automatically extrapolate valuable information such as cross-sections, decomposed portions of the tunnel, and the referenced images from the photogrammetric survey. The long-term research goal is to create an effective workflow, both at the hardware and software level, that can reduce computation times, process large amounts of data, and reduce dependency on high levels of experience
Computerized Analysis of Magnetic Resonance Images to Study Cerebral Anatomy in Developing Neonates
The study of cerebral anatomy in developing neonates is of great importance for
the understanding of brain development during the early period of life. This
dissertation therefore focuses on three challenges in the modelling of cerebral
anatomy in neonates during brain development. The methods that have been
developed all use Magnetic Resonance Images (MRI) as source data.
To facilitate study of vascular development in the neonatal period, a set of image
analysis algorithms are developed to automatically extract and model cerebral
vessel trees. The whole process consists of cerebral vessel tracking from
automatically placed seed points, vessel tree generation, and vasculature
registration and matching. These algorithms have been tested on clinical Time-of-
Flight (TOF) MR angiographic datasets.
To facilitate study of the neonatal cortex a complete cerebral cortex segmentation
and reconstruction pipeline has been developed. Segmentation of the neonatal
cortex is not effectively done by existing algorithms designed for the adult brain
because the contrast between grey and white matter is reversed. This causes pixels
containing tissue mixtures to be incorrectly labelled by conventional methods. The
neonatal cortical segmentation method that has been developed is based on a novel
expectation-maximization (EM) method with explicit correction for mislabelled
partial volume voxels. Based on the resulting cortical segmentation, an implicit
surface evolution technique is adopted for the reconstruction of the cortex in
neonates. The performance of the method is investigated by performing a detailed
landmark study.
To facilitate study of cortical development, a cortical surface registration algorithm
for aligning the cortical surface is developed. The method first inflates extracted
cortical surfaces and then performs a non-rigid surface registration using free-form
deformations (FFDs) to remove residual alignment. Validation experiments using
data labelled by an expert observer demonstrate that the method can capture local
changes and follow the growth of specific sulcus
Vessel tractography using an intensity based tensor model with branch detection
In this paper, we present a tubular structure seg- mentation method that utilizes a second order tensor constructed from directional intensity measurements, which is inspired from diffusion tensor image (DTI) modeling. The constructed anisotropic tensor which is fit inside a vessel drives the segmen- tation analogously to a tractography approach in DTI. Our model is initialized at a single seed point and is capable of capturing whole vessel trees by an automatic branch detection algorithm developed in the same framework. The centerline of the vessel as well as its thickness is extracted. Performance results within the Rotterdam Coronary Artery Algorithm Evaluation framework are provided for comparison with existing techniques. 96.4% average overlap with ground truth delineated by experts is obtained in addition to other measures reported in the paper. Moreover, we demonstrate further quantitative results over synthetic vascular datasets, and we provide quantitative experiments for branch detection on patient Computed Tomography Angiography (CTA) volumes, as well as qualitative evaluations on the same CTA datasets, from visual scores by a cardiologist expert
Vascular Tree Structure: Fast Curvature Regularization and Validation
This work addresses the challenging problem of accurate vessel structure analysis in high resolution 3D biomedical images. Typical segmentation methods fail on recent micro-CT data sets resolving near-capillary vessels due to limitations of standard first-order regularization models. While regularization is needed to address noise and partial volume issues in the data, we argue that extraction of thin tubular structures requires higher-order curvature-based regularization. There are no standard segmentation methods regularizing surface curvature in 3D that could be applied to large 3D volumes. However, we observe that standard measures for vessels structure are more concerned with topology, bifurcation angles, and other parameters that can be directly addressed without segmentation. We propose a novel methodology reconstructing tree structure of the vessels using a new centerline curvature regularization technique. Our high-order regularization model is based on a recent curvature estimation method. We developed a Levenberg-Marquardt optimization scheme and an efficient GPU-based implementation of our algorithm. We also propose a validation mechanism based on synthetic vessel images. Our preliminary results on real ultra-resolution micro CT volumes are promising
Recommended from our members
Automatic 3D Reconstruction of Coronary Artery Centerlines from Monoplane X-ray Angiogram Images
We present a new method for the fully automatic 3D reconstruction of the coronary artery centerlines, using two X-ray angiogram projection images from a single rotating monoplane acquisition system. During the first stage, the input images are smoothed using curve evolution techniques. Next, a simple yet efficient multiscale method, based on the information of the Hessian matrix, for the enhancement of the vascular structure is introduced. Hysteresis thresholding using different image quantiles, is used to threshold the arteries. This stage is followed by a thinning procedure to extract the centerlines. The resulting skeleton image is then pruned using morphological and pattern recognition techniques to remove non-vessel like structures. Finally, edge-based stereo correspondence is solved using a parallel evolutionary optimization method based on f symbiosis. The detected 2D centerlines combined with disparity map information allow the reconstruction of the 3D vessel centerlines. The proposed method has been evaluated on patient data sets for evaluation purposes
- …