6,071 research outputs found

    Chemiluminescence of asbestos-activated macrophages

    Get PDF
    Chemiluminescence, a measure of reactive oxygen release by phagocytes, was compared in peritoneal exudate macrophages elicited with chrysotile asbestos, Corynebacterium parvum and saline. Chrysotile asbestos- and C. parvum-activated macrophages produced significantly more chemiluminescence than saline-elicited macrophages. In a second series of experiments the ability of opsonized chrysotile asbestos to act as a trigger for the release of chemiluminescence was tested. Opsonized chrysotile asbestos produced a dose-related release of chemiluminescence from activated macrophages except at the highest dose where chemiluminescence was reduced due, possibly, to a toxic effect of chrysotile during the assay. Opsonized latex also triggered a dose-related chemiluminescent response from activated macrophages. The potential role of toxic reactive oxygen species, released from macrophages, in the development of asbestos-related pulmonary inflammation and fibrosis are discussed

    Magnetic anisotropy of asbestos fibres

    Get PDF
    Original article can be found at : http://jap.aip.org/jap/ Copyright American Institute of PhysicsThe anisotropy of magnetic susceptibility of single asbestos fibers is measured. The alignment of both chrysotile and crocidolite fibers in magnetic fields is found to be due to the anisotropy. The average measured anisotropy of volume susceptibility is 0.40×10−6 for chrysotile and 83×10−6 for crocidolite. Fiber shape effects are estimated to contribute, on average, about 10% and 6%, respectively, to the total anisotropy of the two types of fiber. There is no evidence of significant permanent magnetic moments. The magnitude of the observed alignment makes the effect potentially useful in real-time detection of airborne asbestos fibers. The experimental technique developed in the study can be used for measuring the anisotropy of small particles of well-defined shape. High sensitivity of the technique permits the measurement of torques lower than 10−21 Nm on particles down to picogram mass.Peer reviewe

    Multiple plasmon resonances in naturally-occurring multiwall nanotubes: infrared spectra of chrysotile asbestos

    Full text link
    Chrysotile asbestos is formed by densely packed bundles of multiwall hollow nanotubes. Each wall in the nanotubes is a cylindrically wrapped layer of Mg3Si2O5(OH)4Mg_3 Si_2 O_5 (OH)_4. We show by experiment and theory that the infrared spectrum of chrysotile presents multiple plasmon resonances in the Si-O stretching bands. These collective charge excitations are universal features of the nanotubes that are obtained by cylindrically wrapping an anisotropic material. The multiple plasmons can be observed if the width of the resonances is sufficiently small as in chrysotile.Comment: 4 pages, 5 figures. Revtex4 compuscript. Misprint in Eq.(6) correcte

    Interactions of asbestos-activated macrophages with an experimental fibrosarcoma

    Get PDF
    Supernatants from in vivo asbestos-activated macrophages failed to show any cytostatic activity against a syngeneic fibrosarcoma cell line in vitro. UICC chrysotile-induced peritoneal exudate cells also failed to demonstrate any growth inhibitory effect on the same cells in Winn assays of tumor growth. Mixing UICC crocidolite with inoculated tumor cells resulted in a dose-dependent inhibition of tumor growth; this could, however, be explained by a direct cytostatic effect on the tumor cells of high doses of crocidolite, which was observed in vitro

    A neural network based spatial light scattering instrument for hazardous airborne fiber detection

    Get PDF
    This paper was published in Applied Optics and is made available as an electronic reprint with the permission of OSA. One print or electronic copy may be made for personal use only. Systematic or multiple reproduction, distribution to multiple locations via electronic or other means, duplication of any material in this paper for a fee or for commercial purposes, or modification of the content of the paper are prohibited. Copyright OSA (www.osa.org/pubs/osajournals.org)A laser light scattering instrument has been designed to facilitate the real-time detection of potentially hazardous respirable fibers, such as asbestos, within an ambient environment. The instrument captures data relating to the spatial distribution of light scattered by individual particles in flow using a dedicated multi-element photodiode detector array. These data are subsequently processed using an artificial neural network which has previously been trained to recognise those features or patterns within the light scattering distribution which may be characteristic of the specific particle types being sought, such as for example, crocidolite or chrysotile asbestos fibers. Each particle is thus classified into one of a limited set of classes based upon its light scattering properties, and from the accumulated data a particle concentration figure for each class may be produced and updated at regular intervals. Particle analysis rates in excess of 103 per second within a sample volume flow-rate of 1 litre per minute are achievable, offering the possibility of detecting fiber concentrations at the recommended maximum exposure limit of 0.1 fibers/ml within a sampling period of a few seconds.Peer reviewe

    A comparison of the results from intra-pleural and intra-peritoneal studies with those from inhalation and intratracheal tests for the assessment of pulmonary responses to inhalable dusts and fibres.

    Get PDF
    The aim of this paper is to compare results from inhalation studies with those from intraperitoneal and intrapleural tests, where available, for a number of fibrous and particulate test materials. The objective is to determine how well intraperitoneal/intrapleural studies predict the pathological responses observed in more standard in vivo studies of pulmonary toxicity, with a particular focus on carcinogenicity. Published toxicity data was obtained for a number of materials including asbestos, wollastonite, MMVFs (including glass fibres, stone wools and RCF), silicon carbide whiskers, potassium octatitanate, quartz, kevlar, polypropylene and titanium dioxide. For some of the fibrous material reviewed, there is conformity between the results of intraperitoneal and inhalation tests such that they are either consistently positive or consistently negative. For the remaining fibrous materials reviewed, intraperitoneal and inhalation tests give different results, with positive results in the intraperitoneal test not being reflected by positive inhalation results. It is suggested that the intraperitoneal test can be used to exonerate a dust or fibre (because if negative in the intraperitoneal test it is extremely unlikely to be positive in either inhalation or intratracheal tests) but should not be used to positively determine that a dust or fibre is carcinogenic by inhalation. We would argue against the use of intraperitoneal tests for human health risk assessment except perhaps for the purpose of exoneration of a material from classification as a carcinogen.Peer reviewedFinal Accepted Versio

    Detection of Hazardous Airborne Fibres

    Get PDF

    Detection of Hazardous Airborne Fibres

    Get PDF

    Materials for electrochemical cell separators Summary report

    Get PDF
    Asbestos and other candidate materials for electrochemical cell separator
    • 

    corecore