1,902 research outputs found

    Comparison of durability indicators obtained by Non Destructive Testing methods to monitor the durability of concrete structures

    No full text
    International audienceThis paper deals with the use of non destructive testing methods (NDT) to assess indicators of concrete durability and mechanical properties of reinforced concrete structures. On site, NDT methods based on electromagnetic or ultrasonic wave propagation (such as radar, impact echo, ultrasonic transmission deviceÉ) are used because they are more or less sensitive to water content and mechanical properties depending on the method. It has been shown, in a former project [1, 2], that the NDT results called Òobservablesî are linked to mechanical and durability indicators (YoungÕs modulus, compressive strength, porosity and saturation degree). Meanwhile, the relationship between observables and indicators depends on the concrete mix design. A calibration protocol is then proposed to get this relationship for the right mix of the reinforced structure studied by using a minimal number of cores. The cores are non-destructively characterised in laboratory or used to determined reference indicators by standardised destructive methods. The aims of this paper are first to present the ND calibration protocol on cores and then to validate this proposed calibration protocol. To achieve this goal, some NDT results obtained on site and on the corresponding core are compared and durability indicators deduced from NDT calibration are compared with reference durability indicators

    Extension and calibration of a Hawkes-based optimal execution model

    Full text link
    We provide some theoretical extensions and a calibration protocol for our former dynamic optimal execution model. The Hawkes parameters and the propagator are estimated independently on financial data from stocks of the CAC40. Interestingly, the propagator exhibits a smoothly decaying form with one or two dominant time scales, but only so after a few seconds that the market needs to adjust after a large trade. Motivated by our estimation results, we derive the optimal execution strategy for a multi-exponential Hawkes kernel and backtest it on the data for round trips. We find that the strategy is profitable on average when trading at the midprice, which is in accordance with violated martingale conditions. However, in most cases, these profits vanish when we take bid-ask costs into account

    Magnetic resonance imaging (MRI) of heavy-metal transport and fate in an artificial biofilm

    Get PDF
    Unlike planktonic systems, reaction rates in biofilms are often limited by mass transport, which controls the rate of supply of contaminants into the biofilm matrix. To help understand this phenomenon, we investigated the potential of magnetic resonance imaging (MRI) to spatially quantify copper transport and fate in biofilms. For this initial study we utilized an artificial biofilm composed of a 50:50 mix of bacteria and agar. MRI successfully mapped Cu2+ uptake into the artificial biofilm by mapping T2 relaxation rates. A calibration protocol was used to convert T2 values into actual copper concentrations. Immobilization rates in the artificial biofilm were slow compared to the rapid equilibration of planktonic systems. Even after 36 h, the copper front had migrated only 3 mm into the artificial biofilm and at this distance from the copper source, concentrations were very low. This slow equilibration is a result of (1) the time it takes copper to diffuse over such distances and (2) the adsorption of copper onto cell surfaces, which further impedes copper diffusion. The success of this trial run indicates MRI could be used to quantitatively map heavy metal transport and immobilization in natural biofilms

    An Empirical-Mathematical Approach for Calibration and Fitting Cell-Electrode Electrical Models in Bioimpedance Tests

    Get PDF
    This paper proposes a new yet efficient method allowing a significant improvement in the on-line analysis of biological cell growing and evolution. The procedure is based on an empirical-mathematical approach for calibration and fitting of any cell-electrode electrical model. It is valid and can be extrapolated for any type of cellular line used in electrical cell-substrate impedance spectroscopy (ECIS) tests. Parameters of the bioimpedance model, acquired from ECIS experiments, vary for each cell line, which makes obtaining results difficult and—to some extent-renders them inaccurate. We propose a fitting method based on the cell line initial characterization,and carry out subsequent experiments with the same line to approach the percentage of well filling and the cell density (or cell number in the well). To perform our calibration technique, the so-called oscillation-based test (OBT) approach is employed for each cell density. Calibration results are validated by performing other experiments with different concentrations on the same cell line with the same measurement technique. Accordingly, a bioimpedance electrical model of each cell line is determined, which is valid for any further experiment and leading to a more precise electrical model of the electrode-cell system. Furthermore, the model parameters calculated can be also used by any other measurement techniques. Promising experimental outcomes for three different cell-lines have been achieved, supporting the usefulness of this technique

    A calibration protocol for population-specific accelerometer cut-points in children

    Get PDF
    PurposeTo test a field-based protocol using intermittent activities representative of children\u27s physical activity behaviours, to generate behaviourally valid, population-specific accelerometer cut-points for sedentary behaviour, moderate, and vigorous physical activity.MethodsTwenty-eight children (46% boys) aged 10&ndash;11 years wore a hip-mounted uniaxial GT1M ActiGraph and engaged in 6 activities representative of children\u27s play. A validated direct observation protocol was used as the criterion measure of physical activity. Receiver Operating Characteristics (ROC) curve analyses were conducted with four semi-structured activities to determine the accelerometer cut-points. To examine classification differences, cut-points were cross-validated with free-play and DVD viewing activities.ResultsCut-points of &le;372, &gt;2160 and &gt;4806 counts&bull;min&minus;1 representing sedentary, moderate and vigorous intensity thresholds, respectively, provided the optimal balance between the related needs for sensitivity (accurately detecting activity) and specificity (limiting misclassification of the activity). Cross-validation data demonstrated that these values yielded the best overall kappa scores (0.97; 0.71; 0.62), and a high classification agreement (98.6%; 89.0%; 87.2%), respectively. Specificity values of 96&ndash;97% showed that the developed cut-points accurately detected physical activity, and sensitivity values (89&ndash;99%) indicated that minutes of activity were seldom incorrectly classified as inactivity.ConclusionThe development of an inexpensive and replicable field-based protocol to generate behaviourally valid and population-specific accelerometer cut-points may improve the classification of physical activity levels in children, which could enhance subsequent intervention and observational studies.<br /

    Robust Intrinsic and Extrinsic Calibration of RGB-D Cameras

    Get PDF
    Color-depth cameras (RGB-D cameras) have become the primary sensors in most robotics systems, from service robotics to industrial robotics applications. Typical consumer-grade RGB-D cameras are provided with a coarse intrinsic and extrinsic calibration that generally does not meet the accuracy requirements needed by many robotics applications (e.g., highly accurate 3D environment reconstruction and mapping, high precision object recognition and localization, ...). In this paper, we propose a human-friendly, reliable and accurate calibration framework that enables to easily estimate both the intrinsic and extrinsic parameters of a general color-depth sensor couple. Our approach is based on a novel two components error model. This model unifies the error sources of RGB-D pairs based on different technologies, such as structured-light 3D cameras and time-of-flight cameras. Our method provides some important advantages compared to other state-of-the-art systems: it is general (i.e., well suited for different types of sensors), based on an easy and stable calibration protocol, provides a greater calibration accuracy, and has been implemented within the ROS robotics framework. We report detailed experimental validations and performance comparisons to support our statements

    High-Throughput NIR-Chemometric Method for Meloxicam Assay from Powder Blends for Tableting

    Get PDF
    A near infrared (NIR) method able to directly quantify the active content in pharmaceutical powder blends used for manufacturing meloxicam tablets, without any sample preparation, was developed and fully validated. To develop calibration models for the assay of meloxicam in powder blends for tableting, the NIR reflectance spectra of different meloxicam powder blends prepared according to a calibration protocol was analysed using different preprocessing methods by partial last-square regression (PLS) and principal component regression (PCR)
    corecore