Color-depth cameras (RGB-D cameras) have become the primary sensors in most
robotics systems, from service robotics to industrial robotics applications.
Typical consumer-grade RGB-D cameras are provided with a coarse intrinsic and
extrinsic calibration that generally does not meet the accuracy requirements
needed by many robotics applications (e.g., highly accurate 3D environment
reconstruction and mapping, high precision object recognition and localization,
...). In this paper, we propose a human-friendly, reliable and accurate
calibration framework that enables to easily estimate both the intrinsic and
extrinsic parameters of a general color-depth sensor couple. Our approach is
based on a novel two components error model. This model unifies the error
sources of RGB-D pairs based on different technologies, such as
structured-light 3D cameras and time-of-flight cameras. Our method provides
some important advantages compared to other state-of-the-art systems: it is
general (i.e., well suited for different types of sensors), based on an easy
and stable calibration protocol, provides a greater calibration accuracy, and
has been implemented within the ROS robotics framework. We report detailed
experimental validations and performance comparisons to support our statements