793 research outputs found

    Colorimetric method for susceptibility testing of voriconazole and other triazoles against Candida species

    Full text link
    Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/72523/1/j.1439-0507.1999.00511.x.pd

    Impact of storage conditions on preparation of activated carbon from sheep wool fibres

    Get PDF
    Received: January 31st, 2023 ; Accepted: June 16th, 2023 ; Published: July 6th, 2023 ; Correspondence: [email protected] the European Union, up to 200 thousand tons (Zoccola et al., 2015) of sheep wool fibres, that are not used for textile fabrication, are a secondary by-product with wide field of application possibilities, including preparation of activated carbon. Taking into account, that wool fibres can be stored for long time, under impact of the local climate conditions (including low temperatures) before their application, for example, under variety of temperature, presence of air and light, different moisture conditions, it is necessary to estimate the impact of wool’s storage conditions on the preparation of activated carbon. In the present work, various parameters, such as, temperature, presence of air and daylight as well as humidity, were selected for comparison. After storage of wool fibres under selected various conditions, thermogravimetry/differential thermal analysis (TG/DTA) followed by with Fourier transform infrared (FTIR) spectrometry were used in order to estimate the impact of each parameter on the thermal decomposition processes: release of moisture, sulphur and nitrogen containing compounds and oxidative degradation followed by release of carbon dioxide. It was estimated, that one year of storage under varying conditions does not significantly affect the thermal decomposition properties of the wool fibres. However, minor impact of humidity absorbed from air on wool is observed. Wool samples that were stored at elevated humidity gave higher residual carbon yield (R) in comparison to the fibres stored in dry conditions. The obtained results are used to develop recommendations for preparation of activated carbon from wool fibres and for its application in air filtrating systems

    Iliac fixation inhibits migration of both suprarenal and infrarenal aortic endografts

    Get PDF
    ObjectiveTo evaluate the role of iliac fixation in preventing migration of suprarenal and infrarenal aortic endografts.MethodsQuantitative image analysis was performed in 92 patients with infrarenal aortic aneurysms (76 men and 16 women) treated with suprarenal (n = 36) or infrarenal (n = 56) aortic endografts from 2000 to 2004. The longitudinal centerline distance from the superior mesenteric artery to the top of the stent graft was measured on preoperative, postimplantation, and 1-year three-dimensional computed tomographic scans, with movement more than 5 mm considered to be significant. Aortic diameters were measured perpendicular to the centerline axis. Proximal and distal fixation lengths were defined as the lengths of stent-graft apposition to the aortic neck and the common iliac arteries, respectively.ResultsThere were no significant differences in age, comorbidities, or preoperative aneurysm size (suprarenal, 6.0 cm; infrarenal, 5.7 cm) between the suprarenal and infrarenal groups. However, the suprarenal group had less favorable aortic necks with a shorter length (13 vs 25 mm; P < .0001), a larger diameter (27 vs 24 mm; P < .0001), and greater angulation (19° vs 11°; P = .007) compared with the infrarenal group. The proximal aortic fixation length was greater in the suprarenal than in the infrarenal group (22 vs 16 mm; P < .0001), with the top of the device closer to the superior mesenteric artery (8 vs 21 mm; P < .0001) as a result of the 15-mm uncovered suprarenal stent. There was no difference in iliac fixation length between the suprarenal and infrarenal groups (26 vs 25 mm; P = .8). Longitudinal centerline stent graft movement at 1 year was similar in the suprarenal and infrarenal groups (4.3 ± 4.4 mm vs 4.8 ± 4.3 mm; P = .6). Patients with longitudinal centerline movement of more than 5 mm at 1 year or clinical evidence of migration at any time during the follow-up period comprised the respective migrator groups. Suprarenal migrators had a shorter iliac fixation length (17 vs 29 mm; P = .006) and a similar aortic fixation length (23 vs 22 mm; P > .999) compared with suprarenal nonmigrators. Infrarenal migrators had a shorter iliac fixation length (18 vs 30 mm; P < .0001) and a similar aortic fixation length (14 vs 17 mm; P = .1) compared with infrarenal nonmigrators. Nonmigrators had closer device proximity to the hypogastric arteries in both the suprarenal (7 vs 17 mm; P = .009) and infrarenal (8 vs 24 mm; P < .0001) groups. No migration occurred in either group in patients with good iliac fixation. Multivariate logistic regression analysis revealed that iliac fixation, as evidenced by iliac fixation length (P = .004) and the device to hypogastric artery distance (P = .002), was a significant independent predictor of migration, whereas suprarenal or infrarenal treatment was not a significant predictor of migration. During a clinical follow-up period of 45 ± 22 months (range, 12-70 months), there have been no aneurysm ruptures, abdominal aortic aneurysm–related deaths, or surgical conversions in either group.ConclusionsDistal iliac fixation is important in preventing migration of both suprarenal and infrarenal aortic endografts that have longitudinal columnar support. Secure iliac fixation minimizes the risk of migration despite suboptimal proximal aortic neck anatomy. Extension of both iliac limbs to cover the entire common iliac artery to the iliac bifurcation seems to prevent endograft migration

    Explant analysis of AneuRx stent grafts: relationship between structural findings and clinical outcome

    Get PDF
    AbstractObjectiveWe reviewed the structural findings of explanted AneuRx stent grafts used to treat abdominal aortic aneurysms, and relate the findings to clinical outcome measures.MethodsWe reviewed data for all bifurcated AneuRx stent grafts explanted at surgery or autopsy and returned to the manufacturer from the US clinical trial and worldwide experience of more than 33,000 implants from 1996 to 2003. Devices implanted for more than 1 month with structural analysis are included in this article. Explant results were analyzed in relation to cause of explantation and pre-explant evidence of endoleak, enlargement, or device migration.ResultsOne hundred twenty explanted stent grafts, including 37 from the US clinical trial, were analyzed. Mean implant duration was 22 ± 13 months (range, 1-61 months). Structural abnormalities included stent fatigue fractures, fabric abrasion holes, and suture breaks. The mean number of nitinol stent strut fractures per explanted device was 3 ± 4, which represents less than 0.2% of the total number of stent struts in each device. The mean number of fabric holes per explanted device was 2 ± 3, with a median hole size of 0.5 mm2. Suture breaks were seen in most explanted devices, but composed less than 1.5% of the total number of sutures per device. “For cause” explants (n = 104) had a 10-month longer implant duration (P = .007) compared with “incidental” explants (n = 16). “For cause” explants had more fractures (3 ± 5; P = .005) and fabric holes (2 ± 3; P = .008) per device compared with “incidental” explants, but these differences were not significant (P = .3) when adjusted for duration of device implantation. Among clinical trial explants the number of fabric holes in grafts in patients with endoleak (2 ± 3 per device) was no different from those without endoleak (3 ± 4 per device; P = NS). The number of fatigue fractures or fabric holes was no different in grafts in clinical trial patients with pre-explant aneurysm enlargement compared with those without enlargement. Pre-explant stent-graft migration was associated with a greater number of stent strut fractures (5 ± 7 per device; P = .04) and fabric holes (3 ± 3 per bifurcation; P = .03) compared with explants without migration. Serial imaging studies revealed inadequate proximal, distal, or junctional device fixation as the probable cause of rupture or need for conversion to open surgery in 86% of “for cause” explants. Structural device abnormalities were usually remote from fixation sites, and no causal relationship between device findings and clinical outcome could be established.ConclusionsNitinol stent fatigue fractures, fabric holes, and suture breaks found in explanted AneuRx stent grafts do not appear to be related to clinical outcome measures. Longer term studies are needed to confirm these observations

    The Red Sea, Coastal Landscapes, and Hominin Dispersals

    Get PDF
    This chapter provides a critical assessment of environment, landscape and resources in the Red Sea region over the past five million years in relation to archaeological evidence of hominin settlement, and of current hypotheses about the role of the region as a pathway or obstacle to population dispersals between Africa and Asia and the possible significance of coastal colonization. The discussion assesses the impact of factors such as topography and the distribution of resources on land and on the seacoast, taking account of geographical variation and changes in geology, sea levels and palaeoclimate. The merits of northern and southern routes of movement at either end of the Red Sea are compared. All the evidence indicates that there has been no land connection at the southern end since the beginning of the Pliocene period, but that short sea crossings would have been possible at lowest sea-level stands with little or no technical aids. More important than the possibilities of crossing the southern channel is the nature of the resources available in the adjacent coastal zones. There were many climatic episodes wetter than today, and during these periods water draining from the Arabian escarpment provided productive conditions for large mammals and human populations in coastal regions and eastwards into the desert. During drier episodes the coastal region would have provided important refugia both in upland areas and on the emerged shelves exposed by lowered sea level, especially in the southern sector and on both sides of the Red Sea. Marine resources may have offered an added advantage in coastal areas, but evidence for their exploitation is very limited, and their role has been over-exaggerated in hypotheses of coastal colonization

    Significant association between host transcriptome‐derived HPV oncogene E6* influence score and carcinogenic pathways, tumor size, and survival in head and neck cancer

    Full text link
    BackgroundHuman papillomavirus (HPV) oncogenes E6, E7, and shorter isoforms of E6 (E6*) are known carcinogenic factors in head and neck squamous cell carcinoma (HNSCC). Little is known regarding E6* functions.MethodsWe analyzed RNA‐seq data from 68 HNSCC HPV type 16‐positive tumors to determine host genes and pathways associated with E6+E7 expression (E6E7) or the percent of full‐length E6 (E6%FL). Influence scores of E6E7 and E6%FL were used to test for associations with clinical variables.ResultsFor E6E7, we recapitulated all major known affected pathways and revealed additional pathways. E6%FL was found to affect mitochondrial processes, and E6%FL influence score was significantly associated with overall survival and tumor size.ConclusionsHPV E6E7 and E6* result in extensive, dose‐dependent compensatory effects and dysregulation of key cancer pathways. The switch from E6 to E6* promotes oxidative phosphorylation, larger tumor size, and worse prognosis, potentially serving as a prognostic factor for HPV‐positive HNSCC.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/156432/2/hed26244.pdfhttp://deepblue.lib.umich.edu/bitstream/2027.42/156432/1/hed26244_am.pd

    A System for Information Management in BioMedical Studies—SIMBioMS

    Get PDF
    Summary: SIMBioMS is a web-based open source software system for managing data and information in biomedical studies. It provides a solution for the collection, storage, management and retrieval of information about research subjects and biomedical samples, as well as experimental data obtained using a range of high-throughput technologies, including gene expression, genotyping, proteomics and metabonomics. The system can easily be customized and has proven to be successful in several large-scale multi-site collaborative projects. It is compatible with emerging functional genomics data standards and provides data import and export in accepted standard formats. Protocols for transferring data to durable archives at the European Bioinformatics Institute have been implemented
    • 

    corecore