785 research outputs found
Musculoskeletal MRI at 7 T: do we need more or is it more than enough?
Ultra-high field magnetic resonance imaging (UHF-MRI) provides important diagnostic improvements in musculoskeletal imaging. The higher signal-to-noise ratio leads to higher spatial and temporal resolution which results in improved anatomic detail and higher diagnostic confidence. Several methods, such as T2, T2*, T1rho mapping, delayed gadolinium-enhanced, diffusion, chemical exchange saturation transfer, and magnetisation transfer techniques, permit a better tissue characterisation. Furthermore, UHF-MRI enables in vivo measurements by low-γ nuclei (23Na, 31P, 13C, and 39K) and the evaluation of different tissue metabolic pathways. European Union and Food and Drug Administration approvals for clinical imaging at UHF have been the first step towards a more routinely use of this technology, but some drawbacks are still present limiting its widespread clinical application. This review aims to provide a clinically oriented overview about the application of UHF-MRI in the different anatomical districts and tissues of musculoskeletal system and its pros and cons. Further studies are needed to consolidate the added value of the use of UHF-MRI in the routine clinical practice and promising efforts in technology development are already in progress
Humeral greater tuberosity osteolysis as a complication of intraosseous calcification migration: Natural history depicted by imaging
Migration of calcification within the bone leading to greater tuberosity osteolysis is a peculiar complication of the calcifying tendinitis of the rotator cuff. The case of a 38-year-old woman complaining of right shoulder pain, which had been going on for one year, is hereby described. The evolution of the infraspinatus tendon calcifying tendinitis leading to osteolysis of the greater tuberosity of the humerus is depicted by imaging and, particularly, by the MR and CT features changing over time. In this paper we focus on the importance of both MR and CT exams in the diagnostic process of the different phases of the disease. The correlation between clinical symptoms and imaging features is also helpful for imaging interpretation: the most painful phase corresponds to the migration of the calcification, whereas pain tends to decrease when the osteolysis develops. Awareness of the existence of this condition may prevent unnecessary invasive procedures. (www.actabiomedica.it)
252. Prediction of subject-specific SAR distribution in MSK MR exam at 7 T
Purpose
we predict SAR during MRI exam using a 7 T 1H 298 MHz eight-channel degenerate birdcage coil1 combining SAR simulations with subject-specific measured (RF) maps.
Materials and Methods
We simulated the coil1 in CST MW Suite, loaded by a model of human knee (Fig. 1, top). was calculated in an axial slice crossing the patella. The maximum local SAR for an Axial “Zero” Time-of-Echo (ZTE) sequence “SILENT”2 was calculated.
We acquired maps of an adult (female) knee with a Bloch-Siegert sequence on 7 axial slices, centered on the same slice of the simulation, on a GE MR950 7T human system. For each slice a coefficient C, proportional to avg, was used to scale the SAR simulated3.
Results
Fig. 1 shows: bottom left, simulated magnitude; bottom center, local SAR for an input of 1 W per channel; bottom right, simulated magnitude for a FA = 90° (length = 3.2 ms) sinc-pulse in the slice previously chosen.
Fig. 2 shows the subject-specific measured for a FA = 90° sinc-pulse. The predicted SAR obtained with scaled maps are 0.50 W/kg (global) and 3.68 W/kg (maximum).
Conclusions
we obtained a good agreement between simulated and measured in vivo maps, and we were able to calculate the distribution of SAR exposure, a safety MRI parameter not available in current exams, where only global SAR is provided, combining simulations and subject-specific measurements. Limits on global and local SAR (20 W/kg) were met for this sequence [1], [2], [3]
The elderly people and his voice
En el presente trabajo, se buscó determinar las características vocales en adultos mayores que asisten a distintos talleres en la Universidad Nacional de San Luis (UNSL), Argentina. La voz en el adulto mayor, no es considerada importante y queda «abandonada». Con el objetivo de determinar las características vocales de este grupo, se realizaron encuestas a directores de algunos de los talleres y, se observaron las características vocales del mismo. La voz senil, debido a un fenómeno natural, se reconoce fácilmente, por ser más ronca, temblorosa, habla más lenta, entre otras.In the present work, we sought to determine the vocal characteristics in older adults who attend to various workshops at the National University of San Luis (UNSL), Argentina. The voice in the elderly, is not considered important and is «abandoned». In order to determine the vocal characteristics of this group surveys to directors of some of the workshops were held and vocal characteristics thereof were observed. Senile voice, due to a natural phenomenon, is easily recognized, for being more hoarse, trembling, slow speech, among others.Informes de Proyectos - Programas de ExtensiónFacultad de Periodismo y Comunicación Socia
Development and tests of a new prototype detector for the XAFS beamline at Elettra Synchrotron in Trieste
The XAFS beamline at Elettra Synchrotron in Trieste combines X-ray absorption
spectroscopy and X-ray diffraction to provide chemically specific structural
information of materials. It operates in the energy range 2.4-27 keV by using a
silicon double reflection Bragg monochromator. The fluorescence measurement is
performed in place of the absorption spectroscopy when the sample transparency
is too low for transmission measurements or the element to study is too diluted
in the sample. We report on the development and on the preliminary tests of a
new prototype detector based on Silicon Drift Detectors technology and the
SIRIO ultra low noise front-end ASIC. The new system will be able to reduce
drastically the time needed to perform fluorescence measurements, while keeping
a short dead time and maintaining an adequate energy resolution to perform
spectroscopy. The custom-made silicon sensor and the electronics are designed
specifically for the beamline requirements.Comment: Proceeding of the 6YRM 12th-14th Oct 2015 - L'Aquila (Italy).
Accepted for publication on Journal of Physics: Conference Serie
Time dependence of the e^- flux measured by PAMELA during the July 2006 - December 2009 solar minimum
Precision measurements of the electron component in the cosmic radiation
provide important information about the origin and propagation of cosmic rays
in the Galaxy not accessible from the study of the cosmic-ray nuclear
components due to their differing diffusion and energy-loss processes. However,
when measured near Earth, the effects of propagation and modulation of galactic
cosmic rays in the heliosphere, particularly significant for energies up to at
least 30 GeV, must be properly taken into account. In this paper the electron
(e^-) spectra measured by PAMELA down to 70 MeV from July 2006 to December 2009
over six-months time intervals are presented. Fluxes are compared with a
state-of-the-art three-dimensional model of solar modulation that reproduces
the observations remarkably well.Comment: 40 pages, 18 figures, 1 tabl
Search for anisotropies in cosmic-ray positrons detected by the PAMELA experiment
The PAMELA detector was launched on board of the Russian Resurs-DK1 satellite
on June 15, 2006. Data collected during the first four years have been used to
search for large-scale anisotropies in the arrival directions of cosmic-ray
positrons. The PAMELA experiment allows for a full sky investigation, with
sensitivity to global anisotropies in any angular window of the celestial
sphere. Data samples of positrons in the rigidity range 10 GV R
200 GV were analyzed. This article discusses the method and the results of the
search for possible local sources through analysis of anisotropy in positron
data compared to the proton background. The resulting distributions of arrival
directions are found to be isotropic. Starting from the angular power spectrum,
a dipole anisotropy upper limit \delta = 0.166 at 95% C.L. is determined.
Additional search is carried out around the Sun. No evidence of an excess
correlated with that direction was found.Comment: The value of the dipole anisotropy upper limit has been changed. The
method is correct but there was a miscalculation in the relative formul
Time dependence of the electron and positron components of the cosmic radiation measured by the PAMELA experiment between July 2006 and December 2015
Cosmic-ray electrons and positrons are a unique probe of the propagation of
cosmic rays as well as of the nature and distribution of particle sources in
our Galaxy. Recent measurements of these particles are challenging our basic
understanding of the mechanisms of production, acceleration and propagation of
cosmic rays. Particularly striking are the differences between the low energy
results collected by the space-borne PAMELA and AMS-02 experiments and older
measurements pointing to sign-charge dependence of the solar modulation of
cosmic-ray spectra. The PAMELA experiment has been measuring the time variation
of the positron and electron intensity at Earth from July 2006 to December 2015
covering the period for the minimum of solar cycle 23 (2006-2009) till the
middle of the maximum of solar cycle 24, through the polarity reversal of the
heliospheric magnetic field which took place between 2013 and 2014. The
positron to electron ratio measured in this time period clearly shows a
sign-charge dependence of the solar modulation introduced by particle drifts.
These results provide the first clear and continuous observation of how drift
effects on solar modulation have unfolded with time from solar minimum to solar
maximum and their dependence on the particle rigidity and the cyclic polarity
of the solar magnetic field.Comment: 11 pages, 2 figure
- …