182 research outputs found

    Validation of a novel particle isolation procedure using particle doped tissue samples.

    Get PDF
    A novel particle isolation method for tissue samples was developed and tested using particle-doped peri-articular tissues from ovine cadavers. This enabled sensitivity of the isolation technique to be established by doping tissue samples of 0.25 g with very low particle volumes of 2.5 ”m 3 per sample. Image analysis was used to verify that the method caused no changes to particle size or morphologies

    Recovery rate data for silicon nitride nanoparticle isolation using sodium polytungstate density gradients

    Get PDF
    © 2018 The Authors The average recovery rate of silicon nitride nanoparticles isolated from serum using the method detailed in previous article “A novel method for isolation and recovery of ceramic nanoparticles and metal wear debris from serum lubricants at ultra-low wear rate” (Lal et al., 2016) [1] was tested gravimetrically by weighing particles doped into serum before and after the isolation process. An average recovery rate of approximately 89.6% (± 7.1 SD) was achieved

    An anatomical study of porcine peripheral nerve and its potential use in nerve tissue engineering

    Get PDF
    yesCurrent nerve tissue engineering applications are adopting xenogeneic nerve tissue as potential nerve grafts to help aid nerve regeneration. However, there is little literature that describes the exact location, anatomy and physiology of these nerves to highlight their potential as a donor graft. The aim of this study was to identify and characterise the structural and extracellular matrix (ECM) components of porcine peripheral nerves in the hind leg. Methods included the dissection of porcine nerves, localisation, characterisation and quantification of the ECM components and identification of nerve cells. Results showed a noticeable variance between porcine and rat nerve (a commonly studied species) in terms of fascicle number. The study also revealed that when porcine peripheral nerves branch, a decrease in fascicle number and size was evident. Porcine ECM and nerve fascicles were found to be predominately comprised of collagen together with glycosaminoglycans, laminin and fibronectin. Immunolabelling for nerve growth factor receptor p75 also revealed the localisation of Schwann cells around and inside the fascicles. In conclusion, it is shown that porcine peripheral nerves possess a microstructure similar to that found in rat, and is not dissimilar to human. This finding could extend to the suggestion that due to the similarities in anatomy to human nerve, porcine nerves may have utility as a nerve graft providing guidance and support to regenerating axons

    Recovery of low volumes of wear debris from rat stifle joint tissues using a novel particle isolation method

    Get PDF
    Less than optimal particle isolation techniques have impeded analysis of orthopaedic wear debris in vivo. The purpose of this research was to develop and test an improved method for particle isolation from tissue. A volume of 0.018 mm³ of clinically relevant CoCrMo, Ti-6Al-4V or Si₃N₄ particles was injected into rat stifle joints for seven days of in vivo exposure. Following sacrifice, particles were located within tissues using histology. The particles were recovered by enzymatic digestion of periarticular tissue with papain and proteinase K, followed by ultracentrifugation using a sodium polytungstate density gradient. Particles were recovered from all samples, observed using SEM and the particle composition was verified using EDX, which demonstrated that all isolated particles were free from contamination. Particle size, aspect ratio and circularity were measured using image analysis software. There were no significant changes to the measured parameters of CoCrMo or Si₃N₄ particles before and after the recovery process (KS tests, p > 0.05). Titanium particles were too few before and after isolation to analyse statistically, though size and morphologies were similar. Overall the method demonstrated a significant improvement to current particle isolation methods from tissue in terms of sensitivity and efficacy at removal of protein, and has the potential to be used for the isolation of ultra-low wearing total joint replacement materials from periprosthetic tissues

    Development and optimisation data of a tissue digestion method for the isolation of orthopaedic wear particles

    Get PDF
    The data contained within this article relate to several enzymatic tissue digestion experiments which were performed to produce an optimised protocol for the digestion of tissue samples. The digestion experiments involved a total of four different digestion protocols. The first protocol involved digestion with proteinase K, without the use of glycine. The second protocol involved digestion with proteinase K in the presence of glycine. The third protocol consisted of proteinase K digestion in the presence of glycine, with more frequent enzyme replenishment. The final protocol was similar to the third protocol but included a papain digestion stage prior to digestion with proteinase K. The data contained within this article are photographs of tissue samples which were captured at key stages of the four protocols and written descriptions based on visual observation of the tissue samples, which document the appearance of the tissue digests

    Effects of Chemical and Radiation Sterilisation on the Biological and Biomechanical Properties of Decellularised Porcine Peripheral Nerves

    Get PDF
    There is a clinical need for novel graft materials for the repair of peripheral nerve defects. A decellularisation process has been developed for porcine peripheral nerves, yielding a material with potentially significant advantages over other devices currently being used clinically (such as autografts and nerve guidance conduits). Grafts derived from xenogeneic tissues should undergo sterilisation prior to clinical use. It has been reported that sterilisation methods may adversely affect the properties of decellularised tissues, and therefore potentially negatively impact on the ability to promote tissue regeneration. In this study, decellularised nerves were produced and sterilised by treatment with 0.1% (v/v) PAA, gamma radiation (25–28 kGy) or E Beam (33–37 kGy). The effect of sterilisation on the decellularised nerves was determined by cytotoxicity testing, histological staining, hydroxyproline assays, uniaxial tensile testing, antibody labelling for collagen type IV, laminin and fibronectin in the basal lamina, and differential scanning calorimetry. This study concluded that decellularised nerves retained biocompatibility following sterilisation. However, sterilisation affected the mechanical properties (PAA, gamma radiation), endoneurial structure and basement membrane composition (PAA) of decellularised nerves. No such alterations were observed following E Beam treatment, suggesting that this method may be preferable for the sterilisation of decellularised porcine peripheral nerves

    To what extent is behaviour a problem in English schools?:Exploring the scale and prevalence of deficits in classroom climate

    Get PDF
    The working atmosphere in the classroom is an important variable in the process of education in schools, with several studies suggesting that classroom climate is an important influence on pupil attainment. There are wide differences in the extent to which classroom climate is considered to be a problem in English schools. Some ‘official’ reports suggest that behaviour in schools is ‘satisfactory or better’ in the vast majority of schools; other sources have pointed to behaviour being a serious and widespread problem. The paper details four studies conducted over the past decade which aimed to explore these disparities. The aim of the research was to gain a more accurate insight into the extent to which deficits in classroom climate limit educational attainment and equality of educational opportunity in English schools. The findings question the suggestion that behaviour is satisfactory or better in 99.7% of English schools and the concluding section suggests ways in which deficits in classroom climate might be addressed. Although the study is limited to classrooms in England, OECD studies suggest that deficits in the working atmosphere in classrooms occur in many countries. The study therefore has potential relevance for education systems in other countries
    • 

    corecore