2,212 research outputs found

    Hydrogen bonding in infinite hydrogen fluoride and hydrogen chloride chains

    Full text link
    Hydrogen bonding in infinite HF and HCl bent (zigzag) chains is studied using the ab initio coupled-cluster singles and doubles (CCSD) correlation method. The correlation contribution to the binding energy is decomposed in terms of nonadditive many-body interactions between the monomers in the chains, the so-called energy increments. Van der Waals constants for the two-body dispersion interaction between distant monomers in the infinite chains are extracted from this decomposition. They allow a partitioning of the correlation contribution to the binding energy into short- and long-range terms. This finding affords a significant reduction in the computational effort of ab initio calculations for solids as only the short-range part requires a sophisticated treatment whereas the long-range part can be summed immediately to infinite distances.Comment: 9 pages, 4 figures, 3 tables, RevTeX4, corrected typo

    Quasiparticle band structure of infinite hydrogen fluoride and hydrogen chloride chains

    Full text link
    We study the quasiparticle band structure of isolated, infinite HF and HCl bent (zigzag) chains and examine the effect of the crystal field on the energy levels of the constituent monomers. The chains are one of the simplest but realistic models of the corresponding three-dimensional crystalline solids. To describe the isolated monomers and the chains, we set out from the Hartree-Fock approximation, harnessing the advanced Green's function methods "local molecular orbital algebraic diagrammatic construction" (ADC) scheme and "local crystal orbital ADC" (CO-ADC) in a strict second order approximation, ADC(2,2) and CO-ADC(2,2), respectively, to account for electron correlations. The configuration space of the periodic correlation calculations is found to converge rapidly only requiring nearest-neighbor contributions to be regarded. Although electron correlations cause a pronounced shift of the quasiparticle band structure of the chains with respect to the Hartree-Fock result, the bandwidth essentially remains unaltered in contrast to, e.g., covalently bound compounds.Comment: 11 pages, 6 figures, 6 tables, RevTeX4, corrected typoe

    Too Afraid to Learn: Attitudes towards Statistics as a Barrier to Learning Statistics and to Acquiring Quantitative Skills

    Get PDF
    Quantitative skills are important for studying and understanding social reality. Political science students, however, experience difficulties in acquiring and retaining such skills. Fear of statistics has often been listed among the major causes for this problem. This study aims at understanding the underlying factors for this anxiety and proposes a potential remedy. More specifically, we advocate the integration of quantitative material into non-methodological courses. After assessing the influence of dispositional, course-related and person-related factors on the attitudes towards statistics among political science students, we provide insights into the relation between these attitudes on the one hand and the learning and retention of statistics skills on the other. Our results indicate that a curriculum-wide approach to normalise the use of quantitative methods can not only foster interest in statistics but also foster retention of the acquired skills

    Multiple internal seal right micro-electro-mechanical system vacuum package

    Get PDF
    A Multiple Internal Seal Ring (MISR) Micro-Electro-Mechanical System (MEMS) vacuum package that hermetically seals MEMS devices using MISR. The method bonds a capping plate having metal seal rings to a base plate having metal seal rings by wafer bonding the capping plate wafer to the base plate wafer. Bulk electrodes may be used to provide conductive paths between the seal rings on the base plate and the capping plate. All seals are made using only metal-to-metal seal rings deposited on the polished surfaces of the base plate and capping plate wafers. However, multiple electrical feed-through metal traces are provided by fabricating via holes through the capping plate for electrical connection from the outside of the package through the via-holes to the inside of the package. Each metal seal ring serves the dual purposes of hermetic sealing and providing the electrical feed-through metal trace

    Multiple internal seal ring micro-electro-mechanical system vacuum packaging method

    Get PDF
    A Multiple Internal Seal Ring (MISR) Micro-Electro-Mechanical System (MEMS) vacuum packaging method that hermetically seals MEMS devices using MISR. The method bonds a capping plate having metal seal rings to a base plate having metal seal rings by wafer bonding the capping plate wafer to the base plate wafer. Bulk electrodes may be used to provide conductive paths between the seal rings on the base plate and the capping plate. All seals are made using only metal-to-metal seal rings deposited on the polished surfaces of the base plate and capping plate wafers. However, multiple electrical feed-through metal traces are provided by fabricating via holes through the capping plate for electrical connection from the outside of the package through the via-holes to the inside of the package. Each metal seal ring serves the dual purposes of hermetic sealing and providing the electrical feed-through metal trace

    Biomarkers of Cerebral Injury for Prediction of Postoperative Cognitive Dysfunction in Patients Undergoing Cardiac Surgery

    Get PDF
    OBJECTIVES: To assess the ability of the biomarkers neuron-specific enolase (NSE), tau, neurofilament light chain (NFL), and glial fibrillary acidic protein (GFAP) to predict postoperative cognitive dysfunction (POCD) at discharge in patients who underwent cardiac surgery. DESIGN: Post hoc analyses (with tests being prespecified before data analyses) from a randomized clinical trial. SETTING: Single-center study from a primary heart center in Denmark. PARTICIPANTS: Adult patients undergoing elective or subacute on-pump coronary artery bypass grafting and/or aortic valve replacement. INTERVENTIONS: Blood was collected before induction of anesthesia, after 24 hours, after 48 hours, and at discharge from the surgical ward. The International Study of Postoperative Cognitive Dysfunction test battery was applied to diagnose POCD at discharge and after three months. Linear mixed models of covariance were used to assess whether repeated measurements of biomarker levels were associated with POCD. Receiver operating characteristic (ROC) curves were applied to assess the predictive value of each biomarker measurement for POCD. MEASUREMENTS AND MAIN RESULTS: A total of 168 patients had biomarkers measured at baseline, and 47 (28%) fulfilled the POCD criteria at discharge. Patients with POCD at discharge had significantly higher levels of tau (p = 0.02) and GFAP (p = 0.01) from baseline to discharge. The biomarker measurements achieving the highest area under the ROC curve for prediction of POCD at discharge were NFL measured at discharge (AUC, 0.64; 95% confidence interval [CI], 0.54-0.73), GFAP measured 48 hours after induction (AUC, 0.64; 95% CI, 0.55-0.73), and GFAP measured at discharge (AUC, 0.64; 95% CI, 0.54-0.74), corresponding to a moderate predictive ability. CONCLUSIONS: Postoperative serum levels of tau and GFAP were elevated significantly in patients with POCD who underwent cardiac surgery at discharge; however, the biomarkers achieved only modest predictive abilities for POCD at discharge. Postoperative levels of NSE were not associated with POCD at discharge

    Oscillatory Shear Flow-Induced Alignment of Lamellar Melts of Hydrogen-Bonded Comb Copolymer Supramolecules

    Get PDF
    In this work we present the orientational behavior of comb copolymer-like supramolecules P4VP(PDP)1.0, obtained by hydrogen bonding between poly(4-vinylpyridine) and pentadecylphenol, during large-amplitude oscillatory shear flow experiments over a broad range of frequencies (0.001-10 Hz). The alignment diagram, presenting the macroscopic alignment in T/TODT vs ω/ωc, contains three regions of parallel alignment separated by a region of perpendicular alignment. For our material, the order-disorder temperature TODT = 67 °C and ωc, the frequency above which the distortion of the chain conformation dominates the materials’ viscoelasticity, is around 0.1 Hz at 61 °C. For the first time flipping from a pure transverse alignment via biaxial transverse/perpendicular alignment to a perpendicular alignment as a function of the strain amplitude was found.
    • …
    corecore