152 research outputs found

    Accuracy and repeatability of wrist joint angles in boxing using an electromagnetic tracking system

    Get PDF
    © 2019, The Author(s). The hand-wrist region is reported as the most common injury site in boxing. Boxers are at risk due to the amount of wrist motions when impacting training equipment or their opponents, yet we know relatively little about these motions. This paper describes a new method for quantifying wrist motion in boxing using an electromagnetic tracking system. Surrogate testing procedure utilising a polyamide hand and forearm shape, and in vivo testing procedure utilising 29 elite boxers, were used to assess the accuracy and repeatability of the system. 2D kinematic analysis was used to calculate wrist angles using photogrammetry, whilst the data from the electromagnetic tracking system was processed with visual 3D software. The electromagnetic tracking system agreed with the video-based system (paired t tests) in both the surrogate ( 0.9). In the punch testing, for both repeated jab and hook shots, the electromagnetic tracking system showed good reliability (ICCs > 0.8) and substantial reliability (ICCs > 0.6) for flexion–extension and radial-ulnar deviation angles, respectively. The results indicate that wrist kinematics during punching activities can be measured using an electromagnetic tracking system

    A continuous-time state-space model for rapid quality-control of Argos locations from animal-borne tags

    Get PDF
    This is the final version. Available on open access from BMC via the DOI in this recordState-space models are important tools for quality control of error-prone animal movement data. The near real-time (within 24 h) capability of the Argos satellite system aids dynamic ocean management of human activities by informing when animals enter intensive use zones. This capability also facilitates use of ocean observations from animal-borne sensors in operational ocean forecasting models. Such near real-time data provision requires rapid, reliable quality control to deal with error-prone Argos locations. We formulate a continuous-time state-space model for the three types of Argos location data (Least-Squares, Kalman filter, and Kalman smoother), accounting for irregular timing of observations. Our model is deliberately simple to ensure speed and reliability for automated, near real-time quality control of Argos data. We validate the model by fitting to Argos data collected from 61 individuals across 7 marine vertebrates and compare model-estimated locations to GPS locations. Estimation accuracy varied among species with median Root Mean Squared Errors usually < 5 km and decreased with increasing data sampling rate and precision of Argos locations. Including a model parameter to inflate Argos error ellipse sizes resulted in more accurate location estimates. In some cases, the model appreciably improved the accuracy of the Argos Kalman smoother locations, which should not be possible if the smoother uses all available information. Our model provides quality-controlled locations from Argos Least-Squares or Kalman filter data with slightly better accuracy than Argos Kalman smoother data that are only available via reprocessing. Simplicity and ease of use make the model suitable both for automated quality control of near real-time Argos data and for manual use by researchers working with historical Argos data.Macquarie UniversityOffice of Naval ResearchIntegrated Marine Observing System - Animal Tracking FacilityOcean Tracking NetworkTaronga Conservation SocietyBirds CanadaInnovasea/VemcoCSIRO Oceans & AtmosphereNational Science Foundation Office of Polar Project

    Detection of diploid males in a natural colony of the cleptobiotic bee Lestrimelitta sp (Hymenoptera, Apidae)

    Get PDF
    When working at quantifying the genome size of stingless bees, it was observed that males of Lestrimelitta sp possessed the same amount of nuclear DNA as the females. Thus, we used flow cytometry (FCM) and cytogenetic analysis to confirm the ploidy of these individuals. The males analyzed proved to be diploid, since, through cytometric analysis, it was demonstrated that the mean genome size of both males and females was the same (C = 0.463 pg), and, furthermore, cytogenetic analysis demonstrated that both had 2n = 28 chromosomes

    Does Kin Recognition and Sib-Mating Avoidance Limit the Risk of Genetic Incompatibility in a Parasitic Wasp?

    Get PDF
    Background: When some combinations of maternal and paternal alleles have a detrimental effect on offspring fitness, females should be able to choose mates on the basis of their genetic compatibility. In numerous Hymenoptera, the sex of an individual depends of the allelic combination at a specific locus (single-locus Complementary Sex Determination), and in most of these species individuals that are homozygous at this sexual locus develop into diploid males with zero fitness. Methods and Findings: In this paper, we tested the hypothesis of genetic incompatibility avoidance by investigating sibmating avoidance in the solitary wasp parasitoid, Venturia canescens. In the context of mate choice we show, for the first time in a non-social hymenopteran species, that females can avoid mating with their brothers through kin recognition. In ‘‘no-choice’ ’ tests, the probability a female will mate with an unrelated male is twice as high as the chance of her mating with her brothers. In contrast, in choice tests in small test arenas, no kin discrimination effect was observed. Further experiments with male extracts demonstrate that chemical cues emanating from related males influence the acceptance rate of unrelated males. Conclusions: Our results are compatible with the genetic incompatibility hypothesis. They suggest that the female wasps recognize sibs on the basis of a chemical signature carried or emitted by males possibly using a ‘‘self-referent phenotyp

    Entropy-driven liquid-liquid separation in supercooled water

    Full text link
    Twenty years ago Poole et al. (Nature 360, 324, 1992) suggested that the anomalous properties of supercooled water may be caused by a critical point that terminates a line of liquid-liquid separation of lower-density and higher-density water. Here we present an explicit thermodynamic model based on this hypothesis, which describes all available experimental data for supercooled water with better quality and with fewer adjustable parameters than any other model suggested so far. Liquid water at low temperatures is viewed as an 'athermal solution' of two molecular structures with different entropies and densities. Alternatively to popular models for water, in which the liquid-liquid separation is driven by energy, the phase separation in the athermal two-state water is driven by entropy upon increasing the pressure, while the critical temperature is defined by the 'reaction' equilibrium constant. In particular, the model predicts the location of density maxima at the locus of a near-constant fraction (about 0.12) of the lower-density structure.Comment: 7 pages, 6 figures. Version 2 contains an additional supplement with tables for the mean-field equatio

    Non-participation in population-based disease prevention programs in general practice

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The number of people with a chronic disease will strongly increase in the next decades. Therefore, prevention of disease becomes increasingly important. The aim of this systematic review was to identify factors that negatively influence participation in population-based disease prevention programs in General Practice and to establish whether the program type is related to non-participation levels.</p> <p>Methods</p> <p>We conducted a systematic review in Pubmed, EMBASE, CINAHL and PsycINFO, covering 2000 through July 6th 2012, to identify publications including information about characteristics of non-participants or reasons for non-participation in population-based disease prevention programs in General Practice.</p> <p>Results</p> <p>A total of 24 original studies met our criteria, seven of which focused on vaccination, eleven on screening aimed at early detection of disease, and six on screening aimed at identifying high risk of a disease, targeting a variety of diseases and conditions. Lack of personal relevance of the program, younger age, higher social deprivation and former non-participation were related to actual non-participation. No differences were found in non-participation levels or factors related to non-participation between the three program types. The large variation in non-participation levels within the program types may be partly due to differences in recruitment strategies, with more active, personalized strategies resulting in higher participation levels compared to an invitation letter.</p> <p>Conclusions</p> <p>There is still much to be gained by tailoring strategies to improve participation in those who are less likely to do so, namely younger individuals, those living in a deprived area and former non-participants. Participation may increase by applying more active recruitment strategies.</p

    A methodological framework to distinguish spectrum effects from spectrum biases and to assess diagnostic and screening test accuracy for patient populations: Application to the Papanicolaou cervical cancer smear test

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>A spectrum effect was defined as differences in the sensitivity or specificity of a diagnostic test according to the patient's characteristics or disease features. A spectrum effect can lead to a spectrum bias when subgroup variations in sensitivity or specificity also affect the likelihood ratios and thus post-test probabilities. We propose and illustrate a methodological framework to distinguish spectrum effects from spectrum biases.</p> <p>Methods</p> <p>Data were collected for 1781 women having had a cervical smear test and colposcopy followed by biopsy if abnormalities were detected (the reference standard). Logistic models were constructed to evaluate both the sensitivity and specificity, and the likelihood ratios, of the test and to identify factors independently affecting the test's characteristics.</p> <p>Results</p> <p>For both tests, human papillomavirus test, study setting and age affected sensitivity or specificity of the smear test (spectrum effect), but only human papillomavirus test and study setting modified the likelihood ratios (spectrum bias) for clinical reading, whereas only human papillomavirus test and age modified the likelihood ratios (spectrum bias) for "optimized" interpretation.</p> <p>Conclusion</p> <p>Fitting sensitivity, specificity and likelihood ratios simultaneously allows the identification of covariates that independently affect diagnostic or screening test results and distinguishes spectrum effect from spectrum bias. We recommend this approach for the development of new tests, and for reporting test accuracy for different patient populations.</p
    corecore