2,838 research outputs found

    Preliminary results on the characterization and performances of ZBLAN fiber for infrared spectrographs

    Full text link
    Present telescopes and future extremely large telescopes make use of fiber-fed spectrographs to observe at optical and infrared wavelengths. The use of fibers largely simplifies the interfacing of the spectrograph to the telescope. At a high spectral resolution (R>50,000) the fibers can be used to achieve very high spectral accuracy. GIANO is an infrared (0.95-2.5\mu m) high resolution (R=50,000) spectrometer[1] [2] [3] that was recently commissioned at the TNG telescope (La Palma). This instrument was designed and built for direct feeding from the telescope [4]. However, due to constraints imposed on the telescope interfacing during the pre-commissioning phase, it had to be positioned on the rotating building, far from the telescope focus. Therefore, a new interface to the telescope, based on IR-transmitting ZBLAN fibers with 85 \mu m core, was developed. In this article we report the first, preliminary results of the effects of these fibers on the quality of the recorded spectra with GIANO and with a similar spectrograph that we set-up in the laboratory. The effects can be primarily associated to modal-noise (MN) that, in GIANO, is much more evident than in optical spectrometers, because of the much longer wavelengths.Comment: 11 pages, 5 figures, 1 table. Presented at SPIE Astronomical Telescope + Instrumentation 2014 (Ground-based and Airbone Instrumentation for Astronomy 5, 9147-231). To be published in Proceeding of SPIE Volume 914

    Can Twitter be a source of information on allergy? Correlation of pollen counts with tweets reporting symptoms of allergic rhinoconjunctivitis and names of antihistamine drugs

    Get PDF
    Pollen forecasts are in use everywhere to inform therapeutic decisions for patients with allergic rhinoconjunctivitis (ARC). We exploited data derived from Twitter in order to identify tweets reporting a combination of symptoms consistent with a case definition of ARC and those reporting the name of an antihistamine drug. In order to increase the sensitivity of the system, we applied an algorithm aimed at automatically identifying jargon expressions related to medical terms. We compared weekly Twitter trends with National Allergy Bureau weekly pollen counts derived from US stations, and found a high correlation of the sum of the total pollen counts from each stations with tweets reporting ARC symptoms (Pearson's correlation coefficient: 0.95) and with tweets reporting antihistamine drug names (Pearson's correlation coefficient: 0.93). Longitude and latitude of the pollen stations affected the strength of the correlation. Twitter and other social networks may play a role in allergic disease surveillance and in signaling drug consumptions trends

    Surgical outcome after isolated on-pump and off-pump anterior descending coronary revascularisation.

    Get PDF
    PRINCIPLES: Anterior descending coronary revascularisation can be performed with or without cardiopulmonary bypass. We compared surgical outcomes and postoperative results of two groups of patients operated on for isolated anterior descending coronary revascularisation with the left internal mammary artery, in order to determine the ideal target patient of each technique. METHODS: From July 1997 to December 2012, 243 consecutive patients underwent off-pump (119) or on-pump (124) surgery for isolated revascularisation of the anterior descending coronary artery. We retrospectively collected, analysed and compared preoperative, intraoperative and postoperative variables. RESULTS: In the on-pump group, aortic cross-clamp and bypass times were 22 and 35 minutes, respectively. Mean surgical time was 126 minutes for the off-pump group and 160 minutes for the on-pump group. Off-pump patients were more often men (82% vs 66%, p = 0.006), older (median age 67 vs 64 years, p = 0.013), with renal failure (11% vs 2.4%, p = 0.009) and respiratory failure (20% vs 7.3%, p = 0.003), with peripheral vascular disease (17% vs 8%, p = 0.038) and affected by a higher degree of angina (p <0.001). Surgical time was shorter off-pump (p <0.001), but a greater number of urgent procedures were performed on-pump (11% vs 3.4%, p = 0.042). No difference in postoperative characteristics and complications except for the intensive care unit stay, which was shorter off-pump (median 1 vs 2 days, p = 0.046). Hospital mortality was 0.8% off-pump and 1.6% on-pump (p = 0.5). CONCLUSION: Both on-pump and off-pump surgery for isolated anterior descending coronary revascularization are safe with equal surgical risk. Off-pump procedures seem to be more appropriate in nonurgent patients with higher surgical risk profiles

    The micro-Jy Radio Source Population: the VLA-CDFS View

    Full text link
    We analyse the 267 radio sources from our deep (flux limit of 42 microJy at the field center at 1.4 GHz) Chandra Deep Field South 1.4 and 5 GHz VLA survey. The radio population is studied by using a wealth of multi-wavelength information, including morphology and spectral types, in the radio, optical, and X-ray bands. The availability of redshifts for ~ 70% of our sources allows us to derive reliable luminosity estimates for the majority of the objects. Contrary to some previous results, we find that star-forming galaxies make up only a minority (~ 1/3) of sub-mJy sources, the bulk of which are faint radio galaxies, mostly of the Fanaroff-Riley I type.Comment: 6 pages, 3 figures, to appear in the proceedings of "At the Edge of the Universe", Sintra, Portugal, Oct. 9 - 13, 200

    The Swift X-ray Telescope Cluster Survey II. X-ray spectral analysis

    Full text link
    (Abridged) We present a spectral analysis of a new, flux-limited sample of 72 X-ray selected clusters of galaxies identified with the X-ray Telescope (XRT) on board the Swift satellite down to a flux limit of ~10-14 erg/s/cm2 (SWXCS, Tundo et al. 2012). We carry out a detailed X-ray spectral analysis with the twofold aim of measuring redshifts and characterizing the properties of the Intra-Cluster Medium (ICM). Optical counterparts and spectroscopic or photometric redshifts are obtained with a cross-correlation with NED. Additional photometric redshifts are computed with a dedicated follow-up program with the TNG and a cross-correlation with the SDSS. We also detect the iron emission lines in 35% of the sample, and hence obtain a robust measure of the X-ray redshift zX. We use zX whenever the optical redshift is not available. Finally, for all the sources with measured redshift, background-subtracted spectra are fitted with a mekal model. We perform extensive spectral simulations to derive an empirical formula to account for fitting bias. The bias-corrected values are then used to investigate the scaling properties of the X-ray observables. Overall, we are able to characterize the ICM of 46 sources. The sample is mostly constituted by clusters with temperatures between 3 and 10 keV, plus 14 low-mass clusters and groups with temperatures below 3 keV. The redshift distribution peaks around z~0.25 and extends up to z~1, with 60% of the sample at 0.1<z<0.4. We derive the Luminosity-Temperature relation for these 46 sources, finding good agreement with previous studies. The quality of the SWXCS sample is comparable to other samples available in the literature and obtained with much larger X-ray telescopes. Our results have interesting implications for the design of future X-ray survey telescopes, characterised by good-quality PSF over the entire field of view and low background.Comment: 27 pages, 15 figures; minor typos corrected. To be published in A&A, Volume 567, July 2014. Websites of the SWXCS project: http://www.arcetri.astro.it/SWXCS/ and http://swxcs.ustc.edu.cn

    Demography of obscured and unobscured AGN: prospects for a Wide Field X-ray Telescope

    Full text link
    We discuss some of the main open issues in the evolution of Active Galactic Nuclei which can be solved by the sensitive, wide area surveys to be performed by the proposed Wide Field X-ray Telescope mission.Comment: Proceedings of "The Wide Field X-ray Telescope Workshop", held in Bologna, Italy, Nov. 25-26 2009. To appear in Memorie della Societa' Astronomica Italiana 2010 (arXiv:1010.5889

    Redshift Evolution in the Iron Abundance of the Intracluster Medium

    Full text link
    Clusters of galaxies provide a closed box within which one can determine the chemical evolution of the gaseous baryons with cosmic time. We studied this metallicity evolution in the hot X-ray emitting baryons through an analysis of XMM-Newton observations of 29 galaxy clusters in the redshift range 0.3 < z < 1.3. Taken alone, this data set does not show evidence for significant evolution. However, when we also include a comparable sample of 115 clusters observed with Chandra (Maughan et al. 2008) and a lower redshift sample of 70 clusters observed with XMM at z < 0.3 (Snowden et al. 2008), there is definitive evidence for a decrease in the metallicity. This decrease is approximately a factor of two from z = 0 to z \approx 1, over which we find a least-squares best-fit line Z(z) / Z_{\odot} = (0.46 \pm 0.05) - (0.38 \pm 0.03)z. The greatest uncertainty in the evolution comes from poorly constrained metallicities in the highest redshift bin

    A new photometric technique for the joint selection of star-forming and passive galaxies at 1.4<z<2.5

    Get PDF
    A simple two color selection based on B-, z-, and K- band photometry is proposed for culling galaxies at 1.4<z<2.5 in K-selected samples and classifying them as star-forming or passive systems. The method is calibrated on the highly complete spectroscopic redshift database of the K20 survey, verified with simulations and tested on other datasets. Requiring BzK=(z-K)-(B-z)>-0.2 (AB) allows to select actively star-forming galaxies at z>1.4, independently on their dust reddening. Instead, objects with BzK<-0.2 and (z-K)>2.5 (AB) colors include passively evolving galaxies at z>1.4, often with spheroidal morphologies. Simple recipes to estimate the reddening, SFRs and masses of BzK-selected galaxies are derived, and calibrated on K<20 galaxies. Based on their UV (reddening-corrected), X-ray and radio luminosities, the BzK-selected star-forming galaxies with K<20 turn out to have average SFR ~ 200 Msun yr^-1, and median reddening E(B-V)~0.4. Besides missing the passively evolving galaxies, the UV selection appears to miss some relevant fraction of the z~2 star-forming galaxies with K<20, and hence of the (obscured) star-formation rate density at this redshift. The high SFRs and masses add to other existing evidence that these z=2 star-forming galaxies may be among the precursors of z=0 early-type galaxies. Theoretical models cannot reproduce simultaneously the space density of both passively evolving and highly star-forming galaxies at z=2. In view of Spitzer Space Telescope observations, an analogous technique based on the RJL photometry is proposed to complement the BzK selection and to identify massive galaxies at 2.5<z<4.0. These color criteria should help in completing the census of the stellar mass and of the star-formation rate density at high redshift (abridged).Comment: 19 pages, 17 figures, to appear on ApJ (20 December 2004 issue

    The Visible and Near Infrared module of EChO

    Full text link
    The Visible and Near Infrared (VNIR) is one of the modules of EChO, the Exoplanets Characterization Observatory proposed to ESA for an M-class mission. EChO is aimed to observe planets while transiting by their suns. Then the instrument had to be designed to assure a high efficiency over the whole spectral range. In fact, it has to be able to observe stars with an apparent magnitude Mv= 9-12 and to see contrasts of the order of 10-4 - 10-5 necessary to reveal the characteristics of the atmospheres of the exoplanets under investigation. VNIR is a spectrometer in a cross-dispersed configuration, covering the 0.4-2.5 micron spectral range with a resolving power of about 330 and a field of view of 2 arcsec. It is functionally split into two channels respectively working in the 0.4-1 and 1.0-2.5 micron spectral ranges. Such a solution is imposed by the fact the light at short wavelengths has to be shared with the EChO Fine Guiding System (FGS) devoted to the pointing of the stars under observation. The spectrometer makes use of a HgCdTe detector of 512 by 512 pixels, 18 micron pitch and working at a temperature of 45K as the entire VNIR optical bench. The instrument has been interfaced to the telescope optics by two optical fibers, one per channel, to assure an easier coupling and an easier colocation of the instrument inside the EChO optical bench.Comment: 26 page
    corecore