1,083 research outputs found

    Motel user manual

    No full text
    MOTEL is a logic-based knowledge representation languages of the KL-ONE family. It contains as a kernel the KRIS language which is a decidable sublanguage of first-order predicate logic. Whereas KRIS is a single-agent knowledge representation system, i.e. KRIS is only able to represent general world knowledge or the knowledge of one agent about the world, MOTEL is a multi-agent knowledge representation system. The MOTEL language allows modal contexts and modal concept forming operators which allow to represent and reason about the believes and wishes of multiple agents. Furthermore it is possible to represent defaults and stereotypes. Beside the basic resoning facilities for consistency checking, classification, and realization, MOTEL provides an abductive inference mechanism. Furthermore it is able to give explanations for its inferences

    Reliability of Intra-Retinal Layer Thickness Estimates

    Get PDF
    Purpose Measurement of intra-retinal layer thickness using optical coherence tomography (OCT) has become increasingly prominent in multiple sclerosis (MS) research. Nevertheless, the approaches used for determining the mean layer thicknesses vary greatly. Insufficient data exist on the reliability of different thickness estimates, which is crucial for their application in clinical studies. This study addresses this lack by evaluating the repeatability of different thickness estimates. Methods Studies that used intra-retinal layer segmentation of macular OCT scans in patients with MS were retrieved from PubMed. To investigate the repeatability of previously applied layer estimation approaches, we generated datasets of repeating measurements of 15 healthy subjects and 13 multiple sclerosis patients using two OCT devices (Cirrus HD-OCT and Spectralis SD-OCT). We calculated each thickness estimate in each repeated session and analyzed repeatability using intra-class correlation coefficients and coefficients of repeatability. Results We identified 27 articles, eleven of them used the Spectralis SD-OCT, nine Cirrus HD-OCT, two studies used both devices and two studies applied RTVue-100. Topcon OCT-1000, Stratus OCT and a research device were used in one study each. In the studies that used the Spectralis, ten different thickness estimates were identified, while thickness estimates of the Cirrus OCT were based on two different scan settings. In the simulation dataset, thickness estimates averaging larger areas showed an excellent repeatability for all retinal layers except the outer plexiform layer (OPL). Conclusions Given the good reliability, the thickness estimate of the 6mm-diameter area around the fovea should be favored when OCT is used in clinical research. Assessment of the OPL was weak in general and needs further investigation before OPL thickness can be used as a reliable parameter

    The structure of a polyketide synthase bimodule core

    Get PDF
    Polyketide synthases (PKSs) are predominantly microbial biosynthetic enzymes. They assemble highly potent bioactive natural products from simple carboxylic acid precursors. The most versatile families of PKSs are organized as assembly lines of functional modules. Each module performs one round of precursor extension and optional modification, followed by directed transfer of the intermediate to the next module. While enzymatic domains and even modules of PKSs are well understood, the higher-order modular architecture of PKS assembly lines remains elusive. Here, we visualize a PKS bimodule core using cryo-electron microscopy and resolve a two-dimensional meshwork of the bimodule core formed by homotypic interactions between modules. The sheet-like organization provides the framework for efficient substrate transfer and for sequestration of trans-acting enzymes required for polyketide production

    Optical properties of metallic (III,Mn)V ferromagnetic semiconductors in the infrared to visible range

    Get PDF
    We report on a study of the ac conductivity and magneto-optical properties of metallic ferromagnetic (III,Mn)V semiconductors in the infrared to visible spectrum. Our analysis is based on the successful kinetic exchange model for (III,Mn)V ferromagnetic semiconductors. We perform the calculations within the Kubo formalism and treat the disorder effects pertubatively within the Born approximation, valid for the metallic regime. We consider an eight-band Kohn-Luttinger model (six valence bands plus two conduction bands) as well as a ten-band model with additional dispersionless bands simulating phenomenologically the upper-mid-gap states induced by antisite and interstitial impurities. These models qualitatively account for optical-absorption experiments and predict new features in the mid-infrared Kerr angle and magnetic-circular-dichroism properties as a function of Mn concentration and free carrier density.Comment: 10 pages, 7 figures, some typos correcte

    Collective effects in spin-crossover chains with exchange interaction

    Full text link
    The collective properties of spin-crossover chains are studied. Spin-crossover compounds contain ions with a low-spin ground state and low lying high-spin excited states and are of interest for molecular memory applications. Some of them naturally form one-dimensional chains. Elastic interaction and Ising exchange interaction are taken into account. The transfer-matrix approach is used to calculate the partition function, the fraction of ions in the high-spin state, the magnetization, susceptibility, etc., exactly. The high-spin-low-spin degree of freedom leads to collective effects not present in simple spin chains. The ground-state phase diagram is mapped out and compared to the case with Heisenberg exchange interaction. The various phases give rise to characteristic behavior at nonzero temperatures, including sharp crossovers between low- and high-temperature regimes. A Curie-Weiss law for the susceptibility is derived and the paramagnetic Curie temperature is calculated. Possible experiments to determine the exchange coupling are discussed.Comment: 9 pages, 13 color figures, published versio

    Criteria for Blood Vessel Discrimination

    Get PDF
    Introduction The diagnostic potential of optical coherence tomography (OCT) in neurological diseases is intensively discussed. Besides the sectional view of the retina, modern OCT scanners produce a simultaneous top-view confocal scanning laser ophthalmoscopy (cSLO) image including the option to evaluate retinal vessels. A correct discrimination between arteries and veins (labeling) is vital for detecting vascular differences between healthy subjects and patients. Up to now, criteria for labeling (cSLO) images generated by OCT scanners do not exist. Objective This study reviewed labeling criteria originally developed for color fundus photography (CFP) images. Methods The criteria were modified to reflect the cSLO technique, followed by development of a protocol for labeling blood vessels. These criteria were based on main aspects such as central light reflex, brightness, and vessel thickness, as well as on some additional criteria such as vascular crossing patterns and the context of the vessel tree. Results and Conclusion They demonstrated excellent inter-rater agreement and validity, which seems to indicate that labeling of images might no longer require more than one rater. This algorithm extends the diagnostic possibilities offered by OCT investigations

    Comparação de Diferentes Parametrizações da Turbulência numa Atmosfera Neutra

    Get PDF
    Comparação de diferentes parametrizações da turbulêncianuma atmosfera neutr

    'Theory for the enhanced induced magnetization in coupled magnetic trilayers in the presence of spin fluctuations'

    Full text link
    Motivated by recent experiments, the effect of the interlayer exchange interaction JinterJ_{inter} on the magnetic properties of coupled Co/Cu/Ni trilayers is studied theoretically. Here the Ni film has a lower Curie temperature TC,NiT_{C,\rm Ni} than the Co film in case of decoupled layers. We show that by taking into account magnetic fluctuations the interlayer coupling induces a strong magnetization for T\gtsim T_{C,\rm Ni} in the Ni film. For an increasing JinterJ_{inter} the resonance-like peak of the longitudinal Ni susceptibility is shifted to larger temperatures, whereas its maximum value decreases strongly. A decreasing Ni film thickness enhances the induced Ni magnetization for T\gtsim T_{C,\rm Ni}. The measurements cannot be explained properly by a mean field estimate, which yields a ten times smaller effect. Thus, the observed magnetic properties indicate the strong effect of 2D magnetic fluctuations in these layered magnetic systems. The calculations are performed with the help of a Heisenberg Hamiltonian and a Green's function approach.Comment: 4 pages, 3 figure

    Estudo da Difusão Empregando´Parâmetros Turbulentos que Descrevem a Capacidade de Mistura da Camada Limite Planetária

    Get PDF
    Estudo da difusão empregando parâmetros turbulentos quedescrevem a capacidade de mistura daCamada Limite Planetári
    corecore