45 research outputs found
Clinical, radiographic, and histologic evaluation of maxillary sinus lift procedure using a highly purified xenogenic graft (Laddec(®))
The aim of this study was to evaluate the clinical, radiographic and histologic results when a highly purified xenogenic bone (Laddec(®)) was used as grafting material in maxillary sinuses
Guided Zygomatic Implantology for Oral Cancer Rehabilitation: A Case Report
Oral rehabilitation after maxillary oncological resection is challenging. This case report presents the rehabilitation of a 65-year-old Caucasian male adenoid cystic carcinoma patient using a myo-cutaneous thigh flap, zygomatic implant placement, and an immediate fixed provisional prosthesis made with computer-aided technologies. The patient presented complaints of asymptomatic enlarged swelling of 5-mm on the right hard hemi-palate. There was an oro-antral communication deriving from a previous local excision. Preoperative radiographs showed the involvement of the right maxilla, maxillary sinus, and nose with a suspect involvement of the maxillary division of the trigeminal nerve. Treatment was planned through a fully digital workflow. A partial maxillectomy was performed endoscopically, and maxilla was reconstructed using an anterolateral thigh free flap. Two zygomatic implants were inserted simultaneously. A provisional fix full-arch prosthesis was manufactured preoperatively through a fully digital workflow and was placed in the operating room. Following post-operative radiotherapy, the patient received a final hybrid prosthesis. During the follow-up period of two years, the patient reported good function, aesthetics, and significant enhancement in quality of life. According to the results of this case, the protocol represented can be a promising alternative for oral cancer patients with large defects, and can lead to an improved quality of life
Corrole Polymers as a Novel Materials for Room Temperature Resistive Gas Sensors
Corroles, a family of contracted porphyrinoids, exhibit broad chemical interactions, undergo straightforward synthetic preparation and functionalization, and enable versatile thin film deposition. These attributes render them promising candidates for use in chemical sensors. Nevertheless, the inherently limited conductivity of corrole solid films constrains their application in mass and optical sensors. Despite this impediment, there is a great interest in matching the sensitive properties of the corrole with the features of facile miniaturization and integration into low-cost electronic circuits. This work explores the possibility of directly and simply depositing conductometric polymeric films of [5,10,15-(4-aminophenyl)corrolato] copper onto interdigitated electrodes. Remarkably, the electropolymerization protocol allows the selection of the semiconductive nature (p- or n-type) of these films, yielding two distinct sensor types: the former exhibiting high sensitivity and selectivity toward nitrogen monoxide (NO) with a slight influence of relative humidity and the other manifesting a broad spectrum of sensitivities. This breakthrough lays the foundation for developing miniaturized conductometric gas detectors, nonlinear conductometric sensing elements, and electronic nose platforms based on polycorroles
Advances in optical sensors for persistent organic pollutant environmental monitoring
Optical chemical sensors are widely applied in many fields of modern analytical practice, due to their simplicity in preparation and signal acquisition, low costs, and fast response time. Moreover, the construction of most modern optical sensors requires neither wire connections with the detector nor sophisticated and energy-consuming hardware, enabling wireless sensor development for a fast, in-field and online analysis. In this review, the last five years of progress (from 2017 to 2021) in the field of optical chemical sensors development for persistent organic pollutants (POPs) is provided. The operating mechanisms, the transduction principles and the types of sensing materials employed in single selective optical sensors and in multisensory systems are reviewed. The selected examples of optical sensors applications are reported to demonstrate the benefits and drawbacks of optical chemical sensor use for POPs assessment
Insolita causa di addome acuto in paziente adulto: l’ileo biliare
L’ileo biliare è una condizione morbosa rara descritta tra le complicanze della litiasi della colecisti. È causa dell’1-3% delle ostruzioni meccaniche del piccolo intestino. Interessa più frequentemente pazienti di età compresa tra 63 e 85 anni. La diagnosi pre-operatoria
è generalmente posta con ritardo variabile da 1 a 10 giorni per l’assenza di una sintomatologia specifica.
Caso clinico. Gli Autori riportano il caso di un uomo di 50 anni in cui è stata posta diagnosi di occlusione meccanica del piccolo intestino da voluminosa concrezione litiasica. L’occlusione ileale è stata dimostrata con la TC. Il paziente è stato sottoposto in urgenza ad intervento
chirurgico, in un unico tempo, di enterolitotomia, colecistectomia e riparazione della fistola duodenale. Il decorso clinico è stato regolare e il paziente è stato dimesso in XIV giornata.
Discussione. Nel nostro caso la diagnosi di ileo biliare è stata posta con un ritardo di 5 giorni. L’ecotomografia del fegato e delle vie biliari non è stata in grado di visualizzare la colecisti. La diagnosi è stata
posta con la TC che si conferma gold standard diagnostico.
Conclusioni. Lo stato clinico del paziente influenza la strategia chirurgica. Nel nostro paziente, considerato a basso rischio, è stato possibile l’intervento chirurgico in un unico tempo. La procedura in due tempi, enterolitotomia e successiva colecistectomia con riparazione della fistola,
va riservata ai pazienti ad alto rischio
Prevalence and clinical impact of endoscopic pseudomembranes in patients with inflammatory bowel disease and Clostridium difficile infection
Background and aim: Limited data suggests that pseudomembranes are uncommon in patients with inflammatory bowel disease (IBD) and C. difficile associated disease (CDAD), but the reason for this is unknown.
We aimed to evaluate the rate of pseudomembranes in this population, identify predictive factors for pseudomembranes' presence and assess its clinical impact.
Methods: This was a sub-study of a retrospective European Crohn's & Colitis Organization (ECCO) multi-center study on the outcome of hospitalized IBD patients with C. difficile. The present study included only patients who underwent lower endoscopy during hospitalization, and compared
demographic and clinical parameters in the group of patients with discernable pseudomembranes versus those without.
Results: Out of 155 patients in the original cohort, 93 patients underwent lower endoscopy and constituted the study population. Endoscopic pseudomembranes were found in 12 (13%) of these patients. Patients with pseudomembranes presented more commonly with fever (p=0.02) compared to patients without pseudomembranes. No difference between the two groups was found with respect to the use of immunosuppressant drugs, background demographics or disease
characteristics. Neither was there a difference between the group with or without pseudomembranes in the frequency of severe adverse clinical outcome or in the duration of hospitalization. On multi-variate analysis the presence of fever remained independently associated with the finding of
pseudomembranes (OR 6, 95% CI 1.2–32, p=0.03).
Conclusions: This study documents that hospitalized IBD patients with CDAD have low rate of endoscopic pseudomembranes, which is not accounted for by the use of immunosuppressant drugs. IBD patients with CDAD and discernable pseudomembranes more commonly present with
fever, but their clinical outcome is similar to patients without pseudomembranes.
© 2009 Published by Elsevier B.V. on behalf of European Crohn's and Colitis Organisation
Geographical and temporal distribution of SARS-CoV-2 clades in the WHO European Region, January to June 2020
We show the distribution of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) genetic clades over time and between countries and outline potential genomic surveillance objectives. We applied three genomic nomenclature systems to all sequence data from the World Health Organization European Region available until 10 July 2020. We highlight the importance of real-time sequencing and data dissemination in a pandemic situation, compare the nomenclatures and lay a foundation for future European genomic surveillance of SARS-CoV-2
Impact of COVID-19 on cardiovascular testing in the United States versus the rest of the world
Objectives: This study sought to quantify and compare the decline in volumes of cardiovascular procedures between the United States and non-US institutions during the early phase of the coronavirus disease-2019 (COVID-19) pandemic.
Background: The COVID-19 pandemic has disrupted the care of many non-COVID-19 illnesses. Reductions in diagnostic cardiovascular testing around the world have led to concerns over the implications of reduced testing for cardiovascular disease (CVD) morbidity and mortality.
Methods: Data were submitted to the INCAPS-COVID (International Atomic Energy Agency Non-Invasive Cardiology Protocols Study of COVID-19), a multinational registry comprising 909 institutions in 108 countries (including 155 facilities in 40 U.S. states), assessing the impact of the COVID-19 pandemic on volumes of diagnostic cardiovascular procedures. Data were obtained for April 2020 and compared with volumes of baseline procedures from March 2019. We compared laboratory characteristics, practices, and procedure volumes between U.S. and non-U.S. facilities and between U.S. geographic regions and identified factors associated with volume reduction in the United States.
Results: Reductions in the volumes of procedures in the United States were similar to those in non-U.S. facilities (68% vs. 63%, respectively; p = 0.237), although U.S. facilities reported greater reductions in invasive coronary angiography (69% vs. 53%, respectively; p < 0.001). Significantly more U.S. facilities reported increased use of telehealth and patient screening measures than non-U.S. facilities, such as temperature checks, symptom screenings, and COVID-19 testing. Reductions in volumes of procedures differed between U.S. regions, with larger declines observed in the Northeast (76%) and Midwest (74%) than in the South (62%) and West (44%). Prevalence of COVID-19, staff redeployments, outpatient centers, and urban centers were associated with greater reductions in volume in U.S. facilities in a multivariable analysis.
Conclusions: We observed marked reductions in U.S. cardiovascular testing in the early phase of the pandemic and significant variability between U.S. regions. The association between reductions of volumes and COVID-19 prevalence in the United States highlighted the need for proactive efforts to maintain access to cardiovascular testing in areas most affected by outbreaks of COVID-19 infection
Sistema e metodo di controllo di una macchina automatica
An automatic machine comprises a production line along which a number of materials is fed and treated to manufacture a product and comprises a plurality of operative members interacting with said materials and/or said final product and which comprise electric and/or electronic components distributed along the production line. A control system of an automatic machine comprises control means (1) of the operation of the automatic machine, which can store and/or process a set of management data and of functionalities of the electric/electronic components and/or of the automatic machine and which comprise data exchange means (2). The control system further comprises communication means, by means of which the control means (1), exclusively through the data exchange means (2), allow access to the management data and/or to the functionalities and/or allow notification of events deriving from the operation of the automatic machine and relating to the management data and/or the functionalities. A user visualization graphic interface which is connectable to the control means through the communication means is provided for providing access to and/or receiving notifications from, the management data and/or the functionalities. The control system comprises a web server (7) comprising web data exchange means (8) that is connectable to the data exchange means (2) of the control means (1) through the communication means, and the graphic interface is of the web type, visualizable as a set of pages in a web browser for an interaction with a user or through a dedicated application, a so-called "app" or "web app", is connectable to the web server (7) and is suitable for accessing and/or receiving notifications from, the management data and/or the functionalities of the control means (1) through the web data exchange means (8) of the web server (7)