1,632 research outputs found

    X ray sensitive area detection device

    Get PDF
    A radiation sensitive area detection device is disclosed which comprises a phosphor-containing film capable of receiving and storing an image formed by a pattern of incoming x rays, UV, or other radiation falling on the film. The device is capable of fluorescing in response to stimulation by a light source in a manner directly proportional to the stored radiation pattern. The device includes: (1) a light source capable of projecting light or other appropriate electromagnetic wave on the film so as to cause it to fluoresce; (2) a means to focus the fluoresced light coming from the phosphor-containing film after light stimulation; and (3) at least one charged coupled detector or other detecting element capable of receiving and digitizing the pattern of fluoresced light coming from the phosphor-containing film. The device will be able to generate superior x ray images of high resolution from a crystal or other sample and will be particularly advantageous in that instantaneous near-real-time images of rapidly deteriorating samples can be obtained. Furthermore, the device can be made compact and sturdy, thus capable of carrying out x ray or other radiation imaging under a variety of conditions, including those experienced in space

    Crystallization of hard-sphere glasses

    Full text link
    We study by molecular dynamics the interplay between arrest and crystallization in hard spheres. For state points in the plane of volume fraction (0.54≤phi≤0.630.54 \leq phi \leq 0.63) and polydispersity (0≤s≤0.0850 \leq s \leq 0.085), we delineate states that spontaneously crystallize from those that do not. For noncrystallizing (or precrystallization) samples we find isodiffusivity lines consistent with an ideal glass transition at ϕg≈0.585\phi_g \approx 0.585, independent of ss. Despite this, for s<0.05s<0.05, crystallization occurs at ϕ>ϕg\phi > \phi_g. This happens on time scales for which the system is aging, and a diffusive regime in the mean square displacement is not reached; by those criteria, the system is a glass. Hence, contrary to a widespread assumption in the colloid literature, the occurrence of spontaneous crystallization within a bulk amorphous state does not prove that this state was an ergodic fluid rather than a glass.Comment: 4 pages, 3 figure

    Hard Spheres: Crystallization and Glass Formation

    Full text link
    Motivated by old experiments on colloidal suspensions, we report molecular dynamics simulations of assemblies of hard spheres, addressing crystallization and glass formation. The simulations cover wide ranges of polydispersity s (standard deviation of the particle size distribution divided by its mean) and particle concentration. No crystallization is observed for s > 0.07. For 0.02 < s < 0.07, we find that increasing the polydispersity at a given concentration slows down crystal nucleation. The main effect here is that polydispersity reduces the supersaturation since it tends to stabilise the fluid but to destabilise the crystal. At a given polydispersity (< 0.07) we find three regimes of nucleation: standard nucleation and growth at concentrations in and slightly above the coexistence region; "spinodal nucleation", where the free energy barrier to nucleation appears to be negligible, at intermediate concentrations; and, at the highest concentrations, a new mechanism, still to be fully understood, which only requires small re-arrangement of the particle positions. The cross-over between the second and third regimes occurs at a concentration, around 58% by volume, where the colloid experiments show a marked change in the nature of the crystals formed and the particle dynamics indicate an "ideal" glass transition

    Crystal Nucleation of Colloidal Suspensions under Shear

    Get PDF
    We use Brownian Dynamics simulations in combination with the umbrella sampling technique to study the effect of shear flow on homogeneous crystal nucleation. We find that a homogeneous shear rate leads to a significant suppression of the crystal nucleation rate and to an increase of the size of the critical nucleus. A simple, phenomenological extension of classical nucleation theory accounts for these observations. The orientation of the crystal nucleus is tilted with respect to the shear direction.Comment: 4 pages, 3 figures, Submitted to Phys. Rev. Let

    Radial vibration measurements directly from rotors using laser vibrometry: The effects of surface roughness, instrument misalignments and pseudo-vibration

    Get PDF
    Laser Doppler vibrometry (LDV) offers an attractive solution when radial vibration measurement directly from a rotor surface is required. Research to date has demonstrated application on polished-circular rotors and rotors coated with retro-reflective tape. In the latter case, however, a significant cross-sensitivity to the orthogonal radial vibration component occurs and post-processing is required to resolve individual radial vibration components. Until now, the fundamentally different behaviour observed between these cases has stood as an inconsistency in the published literature, symptomatic of the need to understand the effect of surface roughness. This paper offers the first consistent mathematical description of the polished-circular and rough rotor behaviours, combined with an experimental investigation of the relationship between surface roughness and cross-sensitivity. Rotors with surface roughness up to 10 nm satisfy the polished-circular rotor definition if vibration displacement is below 100% beam diameter, for a 90 μm beam, and below 40% beam diameter, for a 520 μm beam. On rotors with roughness between 10 nm and 50 nm, the polished-circular rotor definition is satisfied for vibration displacements up to 25% beam diameter, for a 90 μm beam, and up to 10% beam diameter, for a 520 μm beam. As roughness increases, cross-sensitivity increases but only rotors coated in retro-reflective tape satisfied the rough rotor definition fully. Consequently, when polished-circular surfaces are not available, rotor surfaces must be treated with retro-reflective tape and measurements post-processed to resolve individual vibration components. Through simulations, the value of the resolution and correction algorithms that form the post-processor has been demonstrated quantitatively. Simulations incorporating representative instrument misalignments and measurement noise have enabled quantification of likely error levels in radial vibration measurements. On a polished-circular rotor, errors around 0.2% for amplitude and 2 mrad for phase are likely, rising a little at the integer orders affected by pseudo-vibration. Higher pseudo-vibration levels and the need for resolution increase errors in the rough rotor measurements, especially around the synchronous frequency where errors reach 20% by amplitude and 100 mrad for phase. Outside a range of half an order either side of first order, errors are ten times lower and beyond fifth order errors are similar to those for the polished-circular rotor. Further simulations were performed to estimate sensitivities to axial vibration, speed variation and bending vibrations. © 2012 Elsevier Ltd

    RIPK3-deficient mice were not protected from nephrotoxic nephritis

    Get PDF
    Background/Aims: Necrotizing glomerular lesions are a feature of severe glomerulonephritis. Unlike apoptosis, cellular necrosis has the potential to release damage-associated proteins into the microenvironment, thereby potentiating inflammation. Until recently necrosis was thought to be an unregulated cellular response to injury. However, recent evidence suggests that under certain circumstances receptor mediated necrosis occurs in response to death ligand signalling, one form of which is termed necroptosis. RIPK3, a receptor interacting protein, is a limiting step in the intracellular signalling pathway of necroptosis. A non-redundant role for RIPK3 has been implicated in mouse models of renal ischaemia reperfusion injury and toxic renal injury. The aim of this study was to investigate the role of RIPK3 in nephrotoxic nephritis (NTN), a model of immune complex glomerulonephritis in mice. Methods: We induced NTN in RIPK3-/- and WT mice, comparing histology and renal function in both groups. Results: There was no improvement in urinary albumin creatinine ratio, serum urea, glomerular thrombosis or glomerular macrophage infiltration in the RIPK3-/- mice compared to WT. There was also no difference in number of apoptotic cells in glomeruli as measured by TUNEL staining between the RIPK3-/- and WT mice. Conclusion: The data suggests that RIPK3 is not on a critical pathway in the pathogenesis of nephrotoxic nephritis

    The short-time self-diffusion coefficient of a sphere in a suspension of rigid rods

    Full text link
    The short--time self diffusion coefficient of a sphere in a suspension of rigid rods is calculated in first order in the rod volume fraction. For low rod concentrations the correction to the Einstein diffusion constant of the sphere is a linear function of the rod volume fraction with the slope proportional to the equilibrium averaged mobility diminution trace of the sphere interacting with a single freely translating and rotating rod. The two--body hydrodynamic interactions are calculated using the so--called bead model in which the rod is replaced by a stiff linear chain of touching spheres. The interactions between spheres are calculated numerically using the multipole method. Also an analytical expression for the diffusion coefficient as a function of the rod aspect ratio is derived in the limit of very long rods. We show that in this limit the correction to the Einstein diffusion constant does not depend on the size of the tracer sphere. The higher order corrections depending on the applied model are computed numerically. An approximate expression is provided, valid for a wide range of aspect ratios.Comment: 11 pages, 6 figure

    A novel method for high-throughput detection and quantification of neutrophil extracellular traps reveals ROS-independent NET release with immune complexes

    Get PDF
    AbstractA newly-described first-line immune defence mechanism of neutrophils is the release of neutrophil extracellular traps (NETs). Immune complexes (ICxs) induce low level NET release. As such, the in vitro quantification of NETs is challenging with current methodologies. In order to investigate the role of NET release in ICx-mediated autoimmune diseases, we developed a highly sensitive and automated method for quantification of NETs. After labelling human neutrophils with PKH26 and extracellular DNA with Sytox green, cells are fixed and automatically imaged with 3-dimensional confocal laser scanning microscopy (3D-CLSM). NET release is then quantified with digital image analysis whereby the NET amount (Sytox green area) is corrected for the number of imaged neutrophils (PKH26 area). A high sensitivity of the assay is achieved by a) significantly augmenting the area of the well imaged (11%) as compared to conventional assays (0.5%) and b) using a 3D imaging technique for optimal capture of NETs, which are topologically superimposed on neutrophils. In this assay, we confirmed low levels of NET release upon human ICx stimulation which were positive for citrullinated histones and neutrophil elastase. In contrast to PMA-induced NET release, ICx-induced NET release was unchanged when co-incubated with diphenyleneiodonium (DPI). We were able to quantify NET release upon stimulation with serum from RA and SLE patients, which was not observed with normal human serum. To our knowledge, this is the first semi-automated assay capable of sensitive detection and quantification of NET release at a low threshold by using 3D CLSM. The assay is applicable in a high-throughput manner and allows the in vitro analysis of NET release in ICx-mediated autoimmune diseases

    Crystallization Mechanism of Hard Sphere Glasses

    Get PDF
    In supercooled liquids, vitrification generally suppresses crystallization. Yet some glasses can still crystallize despite the arrest of diffusive motion. This ill-understood process may limit the stability of glasses, but its microscopic mechanism is not yet known. Here we present extensive computer simulations addressing the crystallization of monodisperse hard-sphere glasses at constant volume (as in a colloid experiment). Multiple crystalline patches appear without particles having to diffuse more than one diameter. As these patches grow, the mobility in neighbouring areas is enhanced, creating dynamic heterogeneity with positive feedback. The future crystallization pattern cannot be predicted from the coordinates alone: crystallization proceeds by a sequence of stochastic micro-nucleation events, correlated in space by emergent dynamic heterogeneity.Comment: 4 pages 4 figures Accepted for publication in Phys. Rev. Lett., April 201

    On measuring colloidal volume fractions

    Full text link
    Hard-sphere colloids are popular as models for testing fundamental theories in condensed matter and statistical physics, from crystal nucleation to the glass transition. A single parameter, the volume fraction (phi), characterizes an ideal, monodisperse hard-sphere suspension. In comparing experiments with theories and simulation, researchers to date have paid little attention to likely uncertainties in experimentally-quoted phi values. We critically review the experimental measurement of phi in hard-sphere colloids, and show that while statistical uncertainties in comparing relative values of phi can be as low as 0.0001, systematic errors of 3-6% are probably unavoidable. The consequences of this are illustrated by way of a case study comparing literature data sets on hard-sphere viscosity and diffusion.Comment: 11 page
    • …
    corecore