457 research outputs found

    Absolute measurement of the nitrogen fluorescence yield in air between 300 and 430 nm

    Get PDF
    The nitrogen fluorescence induced in air is used to detect ultra-high energy cosmic rays and to measure their energy. The precise knowledge of the absolute fluorescence yield is the key quantity to improve the accuracy on the cosmic ray energy. The total yield has been measured in dry air using a 90Sr source and a [300-430 nm] filter. The fluorescence yield in air is 4.23 ±\pm 0.20 photons per meter when normalized to 760 mmHg, 15 degrees C and with an electron energy of 0.85 MeV. This result is consistent with previous experiments made at various energies, but with an accuracy improved by a factor of about 3. For the first time, the absolute continuous spectrum of nitrogen excited by 90Sr electrons has also been measured with a spectrometer. Details of this experiment are given in one of the author's PhD thesis [32].Comment: accepted for publication in NIM

    Study of the performance of a large scale water-Cherenkov detector (MEMPHYS)

    Full text link
    MEMPHYS (MEgaton Mass PHYSics) is a proposed large-scale water Cherenkov experiment to be performed deep underground. It is dedicated to nucleon decay searches, neutrinos from supernovae, solar and atmospheric neutrinos, as well as neutrinos from a future Super-Beam or Beta-Beam to measure the CP violating phase in the leptonic sector and the mass hierarchy. A full simulation of the detector has been performed to evaluate its performance for beam physics. The results are given in terms of "Migration Matrices" of reconstructed versus true neutrino energy, taking into account all the experimental effects.Comment: Updated after JCAP's referee's comment

    Future large-scale water-Cherenkov detector

    Full text link
    MEMPHYS (MEgaton Mass PHYSics) is a proposed large-scale water-Cherenkov experiment to be performed deep underground. It is dedicated to nucleon decay searches and the detection of neutrinos from supernovae, solar, and atmospheric neutrinos, as well as neutrinos from a future beam to measure the CP violating phase in the leptonic sector and the mass hierarchy. This paper provides an overview of the latest studies on the expected performance of MEMPHYS in view of detailed estimates of its physics reach, mainly concerning neutrino beams

    UV Light Shower Simulator for Fluorescence and Cerenkov Radiation Studies

    Get PDF
    All experiments observing showers light use telescopes equipped with pixellised photodetectors. Monte-Carlo (MC) simulations of the apparatus operation in various situations (background light, shower energy, proximity of tracks...) are mandatory, but never enter into detector details like pulse shape, dead-time, or charge space effects which are finally responsible for the data quality. An apparatus where each pixel receives light from individual 370 nm UV LEDs through silica fibers is being built. The LEDs receive voltage through DACs, which get their input (which pixel, at what time, which amplitude) from a shower plus noise generator code. The typical time constant of a shower being one /mu/mus (300 m for light), the pulses are one /mu/mus wide. This is rather long compared to the intrinsic time constant (around 10 ns) of the light detectors, hence, these see "constant light" changing every /mu/mus. This is where important loading effects which are not included in MC code can be observed. The fibers illuminate the pixels through a diffuser, and each fiber illuminates only one pixel. The number of equipped pixels is such that it englobes a full shower (much less than the full focal surface). Finally, this equipment can be used also to calibrate the pixels

    Establishing a nu_{mu,tau} Component in the Solar Neutrino Flux

    Full text link
    We point out that the recoil electron kinetic energy spectra in the nu-e elastic scattering are different for incident nu_{e} or nu_{mu,tau}, and hence one can in principle establish the existence of the nu_{mu,tau} component in the solar neutrino flux by fitting the shape of the spectrum. This would be a new model-independent test of the solar neutrino oscillation in a single experiment, free from astrophysical and nuclear physics uncertainties. For the ^7Be neutrinos, it is possible to determine the nu_{mu,tau} component at BOREXINO or KamLAND, if the background is sufficiently low. Note that this effect is different from the distortion in the incident neutrino energy spectrum, which has been discussed in the literature.Comment: 12 pages, 3 figures, uses psfig. Figures reorganized, one corrected, conclusions unchange

    MEMPHYS:A large scale water Cerenkov detector at Fr\'ejus

    Full text link
    A water \v{C}erenkov detector project, of megaton scale, to be installed in the Fr\'ejus underground site and dedicated to nucleon decay, neutrinos from supernovae, solar and atmospheric neutrinos, as well as neutrinos from a super-beam and/or a beta-beam coming from CERN, is presented and compared with competitor projects in Japan and in the USA. The performances of the European project are discussed, including the possibility to measure the mixing angle Ξ13\theta_{13} and the CP-violating phase Ύ\delta.Comment: 1+33 pages, 14 figures, Expression of Interest of MEMPHYS projec

    Eigenvector Expansion and Petermann Factor for Ohmically Damped Oscillators

    Full text link
    Correlation functions C(t)∌C(t) \sim in ohmically damped systems such as coupled harmonic oscillators or optical resonators can be expressed as a single sum over modes jj (which are not power-orthogonal), with each term multiplied by the Petermann factor (PF) CjC_j, leading to "excess noise" when ∣Cj∣>1|C_j| > 1. It is shown that ∣Cj∣>1|C_j| > 1 is common rather than exceptional, that ∣Cj∣|C_j| can be large even for weak damping, and that the PF appears in other processes as well: for example, a time-independent perturbation \sim\ep leads to a frequency shift \sim \ep C_j. The coalescence of JJ (>1>1) eigenvectors gives rise to a critical point, which exhibits "giant excess noise" (Cj→∞C_j \to \infty). At critical points, the divergent parts of JJ contributions to C(t)C(t) cancel, while time-independent perturbations lead to non-analytic shifts \sim \ep^{1/J}.Comment: REVTeX4, 14 pages, 4 figures. v2: final, 20 single-col. pages, 2 figures. Streamlined with emphasis on physics over formalism; rewrote Section V E so that it refers to time-dependent (instead of non-equilibrium) effect

    Progress on a spherical TPC for low energy neutrino detection

    Full text link
    The new concept of the spherical TPC aims at relatively large target masses with low threshold and background, keeping an extremely simple and robust operation. Such a device would open the way to detect the neutrino-nucleus interaction, which, although a standard process, remains undetected due to the low energy of the neutrino-induced nuclear recoils. The progress in the development of the fist 1 m3^3 prototype at Saclay is presented. Other physics goals of such a device could include supernova detection, low energy neutrino oscillations and study of non-standard properties of the neutrino, among others.Comment: 3 pages, talk given at the 9th Workshop on Topics in Astroparticle and Underground Physics, Zaragoza, September 10-1

    A first measurement of the interaction cross section of the tau neutrino

    Get PDF
    The DONuT experiment collected data in 1997 and published first results in 2000 based on four observed Μτ\nu_\tau charged-current (CC) interactions. The final analysis of the data collected in the experiment is presented in this paper, based on 3.6×10173.6 \times 10^{17} protons on target using the 800 GeV Tevatron beam at Fermilab. The number of observed Μτ\nu_\tau CC interactions is 9, from a total of 578 observed neutrino interactions. We calculated the energy-independent part of the tau-neutrino CC cross section (Îœ+Μˉ\nu + \bar \nu), relative to the well-known Îœe\nu_e and ΜΌ\nu_\mu cross sections. The ratio σ(Μτ)\sigma(\nu_\tau)/σ(Îœe,ÎŒ)\sigma(\nu_{e,\mu}) was found to be 1.37±0.35±0.771.37\pm0.35\pm0.77. The Μτ\nu_\tau CC cross section was found to be 0.72±0.24±0.36×10−380.72 \pm 0.24\pm0.36 \times 10^{-38} cm2GeV−1^{2}\rm{GeV}^{-1}. Both results are in agreement the Standard Model.Comment: 37 pages, 15 figure

    An Intact Kidney Slice Model to Investigate Vasa Recta Properties and Function in situ

    Get PDF
    Background: Medullary blood flow is via vasa recta capillaries, which possess contractile pericytes. In vitro studies using isolated descending vasa recta show that pericytes can constrict/dilate descending vasa recta when vasoactive substances are present. We describe a live kidney slice model in which pericyte-mediated vasa recta constriction/dilation can be visualized in situ. Methods: Confocal microscopy was used to image calcein, propidium iodide and Hoechst labelling in ‘live’ kidney slices, to determine tubular and vascular cell viability and morphology. DIC video-imaging of live kidney slices was employed to investigate pericyte-mediated real-time changes in vasa recta diameter. Results: Pericytes were identified on vasa recta and their morphology and density were characterized in the medulla. Pericyte-mediated changes in vasa recta diameter (10–30%) were evoked in response to bath application of vasoactive agents (norepinephrine, endothelin-1, angiotensin-II and prostaglandin E2) or by manipulating endogenous vasoactive signalling pathways (using tyramine, L-NAME, a cyclo-oxygenase (COX-1) inhibitor indomethacin, and ATP release). Conclusions: The live kidney slice model is a valid complementary technique for investigating vasa recta function in situ and the role of pericytes as regulators of vasa recta diameter. This technique may also be useful in exploring the role of tubulovascular crosstalk in regulation of medullary blood flow
    • 

    corecore