1,333 research outputs found

    Local cooling for relieving pain from perineal trauma sustained during childbirth

    Get PDF
    Background: Perineal trauma is common during childbirth and may be painful. Contemporary maternity practice includes offering women numerous forms of pain relief, including the local application of cooling treatments. Objectives: To evaluate the effectiveness and side effects of localised cooling treatments compared with no treatment, other forms of cooling treatments and non-cooling treatments. Search strategy: We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (January 2007), CINAHL (1982 to January 2007) and contacted experts in the field. Selection criteria: Published and unpublished randomised and quasi-randomised trials (RCTs) that compared localised cooling treatment applied to the perineum with no treatment or other treatments applied to relieve pain related to perineal trauma sustained during childbirth. Data collection and analysis: At least two independent authors performed data extraction for each study. Analyses were performed on an intention-to-treat basis where data allowed. We sought additional information from the authors of three trials. Main results: Seven published RCTs were included, comparing local cooling treatments (ice packs, cold gel pads or cold/iced baths) with no treatment, hamamelis water (witch hazel), pulsed electromagnetic energy (PET), hydrocortisone/pramoxine foam [Epifoam] or warm baths. The RCTs reported on a total of 859 women. Ice packs provided improved pain relief 24 to 72 hours after birth compared with no treatment (risk ratio (RR) 0.61, 95% confidence interval (CI) 0.41 to 0.91). Women preferred the utility of the gel pads compared with ice packs or no treatment, although no differences in pain relief were detected between the treatments. None of our comparisons of treatments resulted in differences detected in perineal oedema or bruising. Women reported more pain (RR 5.60, 95% CI 2.35 to 13.33) and used more additional analgesia (RR 4.00, 95% CI 1.44 to 11.13) following the application of ice packs compared with PET. Authors' conclusions: There is only limited evidence to support the effectiveness of local cooling treatments (ice packs, cold gel pads, cold/iced baths) applied to the perineum following childbirth to relieve pain

    Determining appropriate imaging parameters for kilovoltage intrafraction monitoring: an experimental phantom study.

    Get PDF
    Kilovoltage intrafraction monitoring (KIM) utilises the kV imager during treatment for real-time tracking of prostate fiducial markers. However, its effectiveness relies on sufficient image quality for the fiducial tracking task. To guide the performance characterisation of KIM under different clinically relevant conditions, the effect of different kV parameters and patient size on image quality, and quantification of MV scatter from the patient to the kV detector panel were investigated in this study. Image quality was determined for a range of kV acquisition frame rates, kV exposure, MV dose rates and patient sizes. Two methods were used to determine image quality; the ratio of kV signal through the patient to the MV scatter from the patient incident on the kilovoltage detector, and the signal-to-noise ratio (SNR). The effect of patient size and frame rate on MV scatter was evaluated in a homogeneous CIRS pelvis phantom and marker segmentation was determined utilising the Rando phantom with embedded markers. MV scatter incident on the detector was shown to be dependent on patient thickness and frame rate. The segmentation code was shown to be successful for all frame rates above 3 Hz for the Rando phantom corresponding to a kV to MV ratio of 0.16 and an SNR of 1.67. For a maximum patient dimension less than 36.4 cm the conservative kV parameters of 5 Hz at 1 mAs can be used to reduce dose while retaining image quality, where the current baseline kV parameters of 10 Hz at 1 mAs is shown to be adequate for marker segmentation up to a patient dimension of 40 cm. In conclusion, the MV scatter component of image quality noise for KIM has been quantified. For most prostate patients, use of KIM with 10 Hz imaging at 1 mAs is adequate however image quality can be maintained and imaging dose reduced by altering existing acquisition parameters

    Determining appropriate imaging parameters for kilovoltage intrafraction monitoring: an experimental phantom study.

    Get PDF
    Kilovoltage intrafraction monitoring (KIM) utilises the kV imager during treatment for real-time tracking of prostate fiducial markers. However, its effectiveness relies on sufficient image quality for the fiducial tracking task. To guide the performance characterisation of KIM under different clinically relevant conditions, the effect of different kV parameters and patient size on image quality, and quantification of MV scatter from the patient to the kV detector panel were investigated in this study. Image quality was determined for a range of kV acquisition frame rates, kV exposure, MV dose rates and patient sizes. Two methods were used to determine image quality; the ratio of kV signal through the patient to the MV scatter from the patient incident on the kilovoltage detector, and the signal-to-noise ratio (SNR). The effect of patient size and frame rate on MV scatter was evaluated in a homogeneous CIRS pelvis phantom and marker segmentation was determined utilising the Rando phantom with embedded markers. MV scatter incident on the detector was shown to be dependent on patient thickness and frame rate. The segmentation code was shown to be successful for all frame rates above 3 Hz for the Rando phantom corresponding to a kV to MV ratio of 0.16 and an SNR of 1.67. For a maximum patient dimension less than 36.4 cm the conservative kV parameters of 5 Hz at 1 mAs can be used to reduce dose while retaining image quality, where the current baseline kV parameters of 10 Hz at 1 mAs is shown to be adequate for marker segmentation up to a patient dimension of 40 cm. In conclusion, the MV scatter component of image quality noise for KIM has been quantified. For most prostate patients, use of KIM with 10 Hz imaging at 1 mAs is adequate however image quality can be maintained and imaging dose reduced by altering existing acquisition parameters

    Analysis of defect-related inhomogeneous electroluminescence in InGaN/GaN QW LEDs

    Get PDF
    The inhomogeneous electroluminescence (EL) of InGaN/GaN quantum well light emitting diode structures was investigated in this study. Electroluminescence hyperspectral images showed that inhomogeneities in the form of bright spots exhibited spectrally blue-shifted and broadened emission. Scanning electron microscopy combined with cathodoluminescence (SEM-CL) was used to identify hexagonal pits at the centre of approximately 20% of these features. Scanning transmission electron microscopy imaging with energy dispersive X-ray spectroscopy (STEM-EDX) indicated there may be p-doped AlGaN within the active region caused by the presence of the pit. Weak beam dark-field TEM (WBDF-TEM) revealed the presence of bundles of dislocations associated with the pit, suggesting the surface features which cause the inhomogeneous EL may occur at coalescence boundaries, supported by trends in the number of features observed across the wafer.The European Research Council has provided financial support under the European Community’s Seventh Framework Programme/ ERC grant agreement no. 279361 (MACONS).This is the author accepted manuscript. The final version is available from Elsevier via http://dx.doi.org/10.1016/j.spmi.2016.03.03

    Unconventional quantum Hall effect and Berry’s phase 2pi in bilayer graphene.

    Get PDF
    There are known two distinct types of the integer quantum Hall effect. One is the conventional quantum Hall effect, characteristic of two-dimensional semiconductor systems, and the other is its relativistic counterpart recently observed in graphene, where charge carriers mimic Dirac fermions characterized by Berry’s phase pi, which results in a shifted positions of Hall plateaus. Here we report a third type of the integer quantum Hall effect. Charge carriers in bilayer graphene have a parabolic energy spectrum but are chiral and exhibit Berry’s phase 2pi affecting their quantum dynamics. The Landau quantization of these fermions results in plateaus in Hall conductivity at standard integer positions but the last (zero-level) plateau is missing. The zero-level anomaly is accompanied by metallic conductivity in the limit of low concentrations and high magnetic fields, in stark contrast to the conventional, insulating behavior in this regime. The revealed chiral fermions have no known analogues and present an intriguing case for quantum-mechanical studies

    Molecular basis of ion permeability in a voltage-gated sodium channel

    Get PDF
    Voltage‐gated sodium channels are essential for electrical signalling across cell membranes. They exhibit strong selectivities for sodium ions over other cations, enabling the finely tuned cascade of events associated with action potentials. This paper describes the ion permeability characteristics and the crystal structure of a prokaryotic sodium channel, showing for the first time the detailed locations of sodium ions in the selectivity filter of a sodium channel. Electrostatic calculations based on the structure are consistent with the relative cation permeability ratios (Na+ ≈ Li+ ≫ K+, Ca2+, Mg2+) measured for these channels. In an E178D selectivity filter mutant constructed to have altered ion selectivities, the sodium ion binding site nearest the extracellular side is missing. Unlike potassium ions in potassium channels, the sodium ions in these channels appear to be hydrated and are associated with side chains of the selectivity filter residues, rather than polypeptide backbones

    Instability in a marginal coral reef: the shift from natural variability to a human-dominated seascape

    Get PDF
    As global climate change drives the demise of tropical reef ecosystems, attention is turning to the suitability o refuge habitat. For the Great Barrier Reef, are there historically stable southern refugia where corals from th north might migrate as climate changes? To address this question, we present a precise chronology of margina coral reef development from Moreton Bay, southeast Queensland, Australia. Our chronology shows that ree growth was episodic, responding to natural environmental variation throughout the Holocene, and tha Moreton Bay was inhospitable to corals for about half of the past 7000 years. The only significant change ii coral species composition occurred between similar to 200 and similar to 50 years ago, following anthropogenic alterations of th, bay and its catchments. Natural historical instability of reefs, coupled with environmental degradation sinc, European colonization, suggests that Moreton Bay offers limited potential as refuge habitat for reef species or human time scales

    Aharonov-Bohm interferences from local deformations in graphene

    Full text link
    One of the most interesting aspects of graphene is the tied relation between structural and electronic properties. The observation of ripples in the graphene samples both free standing and on a substrate has given rise to a very active investigation around the membrane-like properties of graphene and the origin of the ripples remains as one of the most interesting open problems in the system. The interplay of structural and electronic properties is successfully described by the modelling of curvature and elastic deformations by fictitious gauge fields that have become an ex- perimental reality after the suggestion that Landau levels can form associated to strain in graphene and the subsequent experimental confirmation. Here we propose a device to detect microstresses in graphene based on a scanning-tunneling-microscopy setup able to measure Aharonov-Bohm inter- ferences at the nanometer scale. The interferences to be observed in the local density of states are created by the fictitious magnetic field associated to elastic deformations of the sample.Comment: Some bugs fixe
    corecore