886 research outputs found
Mechanized X-ray inspection system for large tanks
Mechanized X ray equipment provides nondestructive inspection of structural weldments at various positions on very large tanks. It mechanizes the placement of the film, automates the identification process, adheres to safety requirements, and eliminates all the usual time-consuming manual operations in industrial radiography
Recommended from our members
Comparison of Analytical and Numerical Methods of Obtaining Coplanar Capacitance of Microelectrodes for Particulate Matter Detection
This work reports a comparative analysis between
the analytical and the finite element modelling, for the calculation
of the capacitance of microelectrode-based capacitors in both
parallel and coplanar architecture. It shows that the inverse-cosine
and the Schwartz-Christoffel methods underestimate the
capacitance value of the coplanar plate capacitor. It also shows
that the parallel architecture closed form solution and the finite
element modelling results agree well in all cases. The work finally
compares the effects of design parameter change of the
microelectrodes on the capacitance obtained from each technique.
It shows that finite element modelling provides the best estimate of
the capacitance of a coplanar plate capacitor
Human Body Digital Twin: A Master Plan
The human body DT has the potential to revolutionize healthcare and wellness,
but its responsible and effective implementation requires consideration of
various factors. This article presents a comprehensive overview of the current
status and future prospects of the human body DT and proposes a five-level
roadmap for its development. The roadmap covers the development of various
components, such as wearable devices, data collection, data analysis, and
decision-making systems. The article also highlights the necessary support,
security, cost, and ethical considerations that must be addressed in order to
ensure responsible and effective implementation of the human body DT. The
proposed roadmap provides a framework for guiding future development and offers
a unique perspective on the future of the human body DT, facilitating new
interdisciplinary research and innovative solutions in this rapidly evolving
field.Comment: 3 figure
Optical phase coherent timing of the Crab nebula pulsar with Iqueye at the ESO New Technology Telescope
The Crab nebula pulsar was observed in 2009 January and December with a novel
very fast optical photon counter, Iqueye, mounted at the ESO 3.5 m New
Technology Telescope. Thanks to the exquisite quality of the Iqueye data, we
computed accurate phase coherent timing solutions for the two observing runs
and over the entire year 2009. Our statistical uncertainty on the determination
of the phase of the main pulse and the rotational period of the pulsar for
short (a few days) time intervals are s and ~0.5 ps,
respectively. Comparison with the Jodrell Bank radio ephemerides shows that the
optical pulse leads the radio one by ~240 s in January and ~160 s in
December, in agreement with a number of other measurements performed after
1996. A third-order polynomial fit adequately describes the spin-down for the
2009 January plus December optical observations. The phase noise is consistent
with being Gaussian distributed with a dispersion of s in most observations, in agreement with theoretical expectations for
photon noise-induced phase variability.Comment: 10 pages, 5 figures. Accepted for publication in Monthly Notices of
the Royal Astronomical Societ
QuantEYE: The Quantum Optics Instrument for OWL
QuantEYE is designed to be the highest time-resolution instrument on ESO:s
planned Overwhelmingly Large Telescope, devised to explore astrophysical
variability on microsecond and nanosecond scales, down to the quantum-optical
limit. Expected phenomena include instabilities of photon-gas bubbles in
accretion flows, p-mode oscillations in neutron stars, and quantum-optical
photon bunching in time. Precise timescales are both variable and unknown, and
studies must be of photon-stream statistics, e.g., their power spectra or
autocorrelations. Such functions increase with the square of the intensity,
implying an enormously increased sensitivity at the largest telescopes.
QuantEYE covers the optical, and its design involves an array of
photon-counting avalanche-diode detectors, each viewing one segment of the OWL
entrance pupil. QuantEYE will work already with a partially filled OWL main
mirror, and also without [full] adaptive optics.Comment: 7 pages; Proceedings from meeting 'Instrumentation for Extremely
Large Telescopes', held at Ringberg Castle, July 2005 (T.Herbst, ed.
Finite element analysis of ground deformation due to dike intrusion with applications to Mt. Etna volcano
A 2D finite elements study was carried out to analyse the effects caused by dike intrusion inside a heterogeneous medium and with a realistic topography of Mt. Etna volcano. Firstly, the method (dimension domain, elements type) was calibrated using plane strain models in elastic half-spaces; the results were compared with those obtained from analytical dislocation models. Then the effects caused both by the topographic variations and the presence of multi-layered medium on the surface, were studied. In particular, an application was then considered to Mt. Etna by taking into account the real topography and the stratification deduced from seismic tomography. In these conditions, the effects expected by the dike, employed to model the 2001 eruption under simple elastic half-space medium conditions, were computed, showing that topography is extremely important, at least in the near field
Recommended from our members
Machine learning methods for automatic silent speech recognition using a wearable graphene strain gauge sensor
Silent speech recognition is the ability to recognise intended speech without audio information. Useful applications can be found in situations where sound waves are not produced or cannot be heard. Examples include speakers with physical voice impairments or environments in which audio transference is not reliable or secure. Developing a device which can detect non-auditory signals and map them to intended phonation could be used to develop a device to assist in such situations. In this work, we propose a graphene-based strain gauge sensor which can be worn on the throat and detect small muscle movements and vibrations. Machine learning algorithms then decode the non-audio signals and create a prediction on intended speech. The proposed strain gauge sensor is highly wearable, utilising graphene’s unique and beneficial properties including strength, flexibility and high conductivity. A highly flexible and wearable sensor able to pick up small throat movements is fabricated by screen printing graphene onto lycra fabric. A framework for interpreting this information is proposed which explores the use of several machine learning techniques to predict intended words from the signals. A dataset of 15 unique words and four movements, each with 20 repetitions, was developed and used for the training of the machine learning algorithms. The results demonstrate the ability for such sensors to be able to predict spoken words. We produced a word accuracy rate of 55% on the word dataset and 85% on the movements dataset. This work demonstrates a proof-of-concept for the viability of combining a highly wearable graphene strain gauge and machine leaning methods to automate silent speech recognition.EP/S023046/
European Non-native Species in Aquaculture Risk Analysis Scheme - a summary of assessment protocols and decision support tools for use of alien species in aquaculture
The European Non-native Species in Aquaculture Risk Analysis Scheme (ENSARS) was developed in response to European 'Council Regulation No. 708/2007 of 11 June 2007 concerning use of alien and locally absent species in aquaculture' to provide protocols for identifying and evaluating the potential risks of using non-native species in aquaculture. ENSARS is modular in structure and adapted from non-native species risk assessment schemes developed by the European and Mediterranean Plant Protection Organisation and for the UK. Seven of the eight ENSARS modules contain protocols for evaluating the risks of escape, introduction to and establishment in open waters, of any non-native aquatic organism being used (or associated with those used) in aquaculture, that is, transport pathways, rearing facilities, infectious agents, and the potential organism, ecosystem and socio-economic impacts. A concluding module is designed to summarise the risks and consider management options. During the assessments, each question requires the assessor to provide a response and confidence ranking for that response based on expert opinion. Each module can also be used individually, and each requires a specific form of expertise. Therefore, a multidisciplinary assessment team is recommended for its completion
- …