680 research outputs found

    A CLASSIFICAÇÃO DE BRECHAS MAGMÁTICAS E SUA IMPLICAÇÃO NA EVOLUÇÃO DO COMPLEXO ALCALINO DE NOVA IGUAÇU – RJ

    Get PDF
    To understand magmatic phenomena, it is important to know how the bodies had been lodged in lithosphere, and the best registers of the formation of a magmatic chamber are the magmatic breccias. They are formed in the contact between the pluton and the host rocks. The classification proposal, in general, allows the reconstruction of the emplacement of the magma, through the description of certain textures and structures found in the units that may be sequenced and associated to magmatic processes, and of the geodynamic context of the volcanic environment, when structural data are taken into account. The rocks in the northeast of the Nova Iguaçu Alkaline Complex are an example. There, some characteristics had been observed: textural maturity, clast/ matrix relationship and characteristics of matrix and clasts. The methodology involved mapping in 1:10.000 scale, petrography, analysis of sections by electron microscope and chemical semi-quantitative analyses. These characteristics, allowed to recognize that the emplacement of the alkaline complex occurred in three phases: first, the break-up of host gneisses, besides the volumetric expansion of the pluton and thermal exchanges between the pluton and surroundings; second, the hydrotermal action of magmatic fluids; third, the intrusion of magma between blocks. This process repeated continuously in each magmatic pulsePara compreender os fenômenos de magmatismo é importante saber de que forma os corpos se alojaram na litosfera, e os melhores registros da formação da câmara magmática são as brechas magmáticas. Elas são formadas no contato do plúton e as rochas encaixantes. A proposta de classificação, em geral, permite a reconstrução do emplacement do magma, através da descrição de determinadas texturas e estruturas encontradas nas unidades que podem ser colocadas em ordem temporal e associadas a processos magmáticos, e do contexto geodinâmico do ambiente vulcânico, quando relacionados a dados estruturais. As rochas encontradas no nordeste do Complexo Alcalino de Nova Iguaçu constituem um exemplo. Nelas, algumas características foram observadas: a maturidade textural, a relação clasto/ matriz e características dos mesmos. A metodologia envolveu o mapeamento 1:10.000, a petrografia, análise de seções no microscópio eletrônico e análises químicas semiquantitativas. Através da descrição dos parâmetros acima, reconhece-se que o emplacement do complexo alcalino deu-se em três fases: a primeira, de quebra da encaixante por expansão volumétrica do corpo e trocas térmicas entre o corpo e as interfaces, a segunda, de ação hidrotermal dos fluidos magmáticos, e a terceira, de intrusão do magma por entre os blocos. Este processo repetiu-se continuamente a cada pulso magmátic

    Desenvolvimento e validação de um método para quantificação de norfloxacino por cromatografia líquida de alta eficiência e aplicação a estudo de farmacocinética comparada em voluntários humanos

    Get PDF
    The development and validation of a simple and accurate method based on HPLC with ultraviolet detection for the quantification of norfloxacin (NFX) in human plasma and its application to a bioequivalence study between two norfloxacin formulations is described. NFX and the internal standard (cyprofloxacin) were extracted from plasma using liquid-liquid extraction. Chromatographic separation of norfloxacin, cyprofloxacin and plasma interferents was achieved with a C-18 column and a mobile phase consisting of 20 mM sodium hydrogen phosphate buffer pH 3.0 and acetonitrile (88:12, v/v) and quantitation was done at 280 nm. The method was linear from 25 to 3000 ng mL-1 (r² >; 0.997578), and norfloxacin and cyprofloxacin had an average recovery from plasma of 93.9% and 91.2% respectively. The RSD of inter-day quality control samples at the lower limit of quantification was less than 15%. After a single oral dose (400 mg) of norfloxacin administered to healthy human volunteers using a randomized 2x2 crossover design, pharmacokinetic parameters (AUC0-t, AUC0-;¥;, Cmax, t1/2) were derived from the plasma concentration curves for both formulations. Pharmacokinetic analysis of the data showed that the two formulations were bioequivalent, while no adverse reactions to the drug were observed.O desenvolvimento e validação de um método simples e preciso por CLAE-UV para quantificação de norfloxacino (NFX) em plasma humano e a sua aplicação a um estudo de bioequivalência entre duas formulações são descritos. NFX e o padrão interno (ciprofloxacino, PI) foram extraídos do plasma através de extração líquido-líquido. A separação cromatográfica do NFX, do PI e dos interferentes do plasma foi realizada com uma coluna C-18 e fase móvel composta de tampão fosfato de sódio 20 mM pH 3,0 e acetonitrila (88/12, v/v) e quantificado em 280 nm. A resposta do detector aos analitos mostrou-se linear entre 25 a 3000 ng mL-1 (r² >; 0,997578) e a recuperação média de NFX e PI foi de 93,9% e 91,2% respectivamente. O desvio padrão relativo de amostras analisadas ao nível do limite inferior de quantificação foi menor que 15%. Foi administrada uma dose de NFX (400 mg) por via oral a voluntários humanos em um estudo aberto, aleatório e cruzado 2x2 entre duas formulações. Os parâmetros farmacocinéticos (AUC0-t, AUC0-;¥;, Cmáx, T1/2) foram observados a partir da curva de concentração versus tempo. A análise farmacocinética mostrou que as duas formulações são bioequivalentes entre si. Nenhum efeito adverso foi observado

    A sensitive and robust lc-ms/ms method with monolithic column and electrospray ionization for the quantitation of efavirenz in human plasma: application to a bioequivalence study

    Full text link
    An LC-MS/MS method has been developed for the determination of efavirenz (EFZ) in human plasma using hydrochlorothiazide as internal standard (I.S.). An ESI negative mode with multiple reaction-monitoring was used monitoring the transitions m/z 313.88→69.24 (EFZ) and 296.02→204.76 (I.S.). Samples were extracted using liquid-liquid extraction. The total run time was 2.0 min. The separation was achieved with HPLC-RP using a monolithic column. The assay was linear in the concentration range of 100 - 5000 ng mL-1. The mean recovery was 83%. Intra- and inter-day precision were < 9.5% and < 8.9%, respectively and accuracy was in the range ± 8.33%. The method was successfully applied to a bioequivalence study

    Nd and Sr Isotopic, Geochemical and Petrographic Characteristics of the Morro de São João Alkaline Intrusion: Geodynamic Implications and the Composition of the Sub-lithosperical Mantle

    Get PDF
    The Morro de São João Alkaline Complex (MSJ) is located in the NE part of Rio de Janeiro State and shows pronounced topography, with the following lithology: coarse-grained felsic syenites (K-feldspar, nepheline, hornblende, titanite and pseudoleucite), and mafic syenites (with K-feldspar, hornblende and piroxene). Petrography and lithogeochemistry data suggest a bimodal suite. Felsic and mafic magma mixing and mingling textures are locally observed indicating the presence of coeval magmas. Nd and Sr isotope compositions correspond to EMI (Enriched Mantle I) mantle reservoir signatures, suggesting an asthenospheric enriched mantle source with low 87Sr/86Sr values (from 0.7049 to 0.7061) and low 143Nd/144Nd (from 0.512361 to 0.512428). The &#949;Nd values range from -4.03 to -5.54, indicating an anomalous enriched mantle reservoir, confirmed by the high T DM values between 730 - 830 Ma, very different from the 72 - 56 Ma K-Ar cooling ages. The comparison of Sr and Nd signatures with related hotspot traces (Trindade, St. Helena and Tristan da Cunha) indicates that they are similar to those of Tristan da Cunha, but somewhat different from those of Trindade and St. Helena.O Complexo Alcalino do Morro de São João está localizado a NE do Estado do Rio de Janeiro e se destaca pelo desnível acentuado do relevo, sendo composto por dois tipos de rochas: sienitos félsicos de granulometria grossa (K-feldspato, nefelina, hornblenda e titanita, além de pseudoleucita) e melassienitos (com K-feldspato, anfibólio e piroxênio). Dados litogeoquímicos sugerem uma suíte bimodal e observações de campo indicam texturas de misturas de magmas e mingling locais, sugerindo que ambos foram contemporâneos. Os resultados isotópicos de Nd e Sr indicam valores próximos do EMI (Enriched Mantle I - Manto Enriquecido tipo I), sugerindo que a origem destas rochas ocorreu no manto sublitosférico a partir de um reservatório enriquecido com baixos valores 87Sr/86Sr (entre 0,7049 e 0,7061) e 143Nd/144Nd (entre 0,512361 e 0,512428). Os valores de &#949;Nd entre -4,03 e -5,54 indicam uma fonte mantélica anâmala e enriquecida, o que é corroborado pelos valores de T DM entre 730 - 830 Ma, discordantes com idades de resfriamento K-Ar, que possuem valores entre 72 - 56 Ma. A comparação das assinaturas isotópicas de Sr e Nd das rochas do Morro de São João com ilhas vulcânicas (Trindade, Santa Helena e Tristão da Cunha) indicam que elas possuem similaridades com Tristão da Cunha e certa discrepância em relação à s assinaturas de Trindade e Santa Helena

    I Diretriz brasileira de cardio-oncologia pediátrica da Sociedade Brasileira de Cardiologia

    Get PDF
    Sociedade Brasileira de Oncologia PediátricaUniversidade Federal de São Paulo (UNIFESP) Instituto de Oncologia Pediátrica GRAACCUniversidade Federal de São Paulo (UNIFESP)Universidade de São Paulo Faculdade de Medicina Instituto do Coração do Hospital das ClínicasUniversidade Federal do Rio Grande do Sul Hospital de Clínicas de Porto AlegreInstituto Materno-Infantil de PernambucoHospital de Base de BrasíliaUniversidade de Pernambuco Hospital Universitário Oswaldo CruzHospital A.C. CamargoHospital do CoraçãoSociedade Brasileira de Cardiologia Departamento de Cardiopatias Congênitas e Cardiologia PediátricaInstituto Nacional de CâncerHospital Pequeno PríncipeSanta Casa de Misericórdia de São PauloInstituto do Câncer do Estado de São PauloUniversidade Federal de São Paulo (UNIFESP) Departamento de PatologiaHospital Infantil Joana de GusmãoUNIFESP, Instituto de Oncologia Pediátrica GRAACCUNIFESP, Depto. de PatologiaSciEL

    Diretrizes Brasileiras de Medidas da Pressão Arterial Dentro e Fora do Consultório – 2023

    Get PDF
    Hypertension is one of the primary modifiable risk factors for morbidity and mortality worldwide, being a major risk factor for coronary artery disease, stroke, and kidney failure. Furthermore, it is highly prevalent, affecting more than one-third of the global population. Blood pressure measurement is a MANDATORY procedure in any medical care setting and is carried out by various healthcare professionals. However, it is still commonly performed without the necessary technical care. Since the diagnosis relies on blood pressure measurement, it is clear how important it is to handle the techniques, methods, and equipment used in its execution with care. It should be emphasized that once the diagnosis is made, all short-term, medium-term, and long-term investigations and treatments are based on the results of blood pressure measurement. Therefore, improper techniques and/or equipment can lead to incorrect diagnoses, either underestimating or overestimating values, resulting in inappropriate actions and significant health and economic losses for individuals and nations. Once the correct diagnosis is made, as knowledge of the importance of proper treatment advances, with the adoption of more detailed normal values and careful treatment objectives towards achieving stricter blood pressure goals, the importance of precision in blood pressure measurement is also reinforced. Blood pressure measurement (described below) is usually performed using the traditional method, the so-called casual or office measurement. Over time, alternatives have been added to it, through the use of semi-automatic or automatic devices by the patients themselves, in waiting rooms or outside the office, in their own homes, or in public spaces. A step further was taken with the use of semi-automatic devices equipped with memory that allow sequential measurements outside the office (ABPM; or HBPM) and other automatic devices that allow programmed measurements over longer periods (HBPM). Some aspects of blood pressure measurement can interfere with obtaining reliable results and, consequently, cause harm in decision-making. These include the importance of using average values, the variation in blood pressure during the day, and short-term variability. These aspects have encouraged the performance of a greater number of measurements in various situations, and different guidelines have advocated the use of equipment that promotes these actions. Devices that perform HBPM or ABPM, which, in addition to allowing greater precision, when used together, detect white coat hypertension (WCH), masked hypertension (MH), sleep blood pressure alterations, and resistant hypertension (RHT) (defined in Chapter 2 of this guideline), are gaining more and more importance. Taking these details into account, we must emphasize that information related to diagnosis, classification, and goal setting is still based on office blood pressure measurement, and for this reason, all attention must be given to the proper execution of this procedure.La hipertensión arterial (HTA) es uno de los principales factores de riesgo modificables para la morbilidad y mortalidad en todo el mundo, siendo uno de los mayores factores de riesgo para la enfermedad de las arterias coronarias, el accidente cerebrovascular (ACV) y la insuficiencia renal. Además, es altamente prevalente y afecta a más de un tercio de la población mundial. La medición de la presión arterial (PA) es un procedimiento OBLIGATORIO en cualquier atención médica o realizado por diferentes profesionales de la salud. Sin embargo, todavía se realiza comúnmente sin los cuidados técnicos necesarios. Dado que el diagnóstico se basa en la medición de la PA, es claro el cuidado que debe haber con las técnicas, los métodos y los equipos utilizados en su realización. Debemos enfatizar que una vez realizado el diagnóstico, todas las investigaciones y tratamientos a corto, mediano y largo plazo se basan en los resultados de la medición de la PA. Por lo tanto, las técnicas y/o equipos inadecuados pueden llevar a diagnósticos incorrectos, subestimando o sobreestimando valores y resultando en conductas inadecuadas y pérdidas significativas para la salud y la economía de las personas y las naciones. Una vez realizado el diagnóstico correcto, a medida que avanza el conocimiento sobre la importancia del tratamiento adecuado, con la adopción de valores de normalidad más detallados y objetivos de tratamiento más cuidadosos hacia metas de PA más estrictas, también se refuerza la importancia de la precisión en la medición de la PA. La medición de la PA (descrita a continuación) generalmente se realiza mediante el método tradicional, la llamada medición casual o de consultorio. Con el tiempo, se han agregado alternativas a través del uso de dispositivos semiautomáticos o automáticos por parte del propio paciente, en salas de espera o fuera del consultorio, en su propia residencia o en espacios públicos. Se dio un paso más con el uso de dispositivos semiautomáticos equipados con memoria que permiten mediciones secuenciales fuera del consultorio (AMPA; o MRPA) y otros automáticos que permiten mediciones programadas durante períodos más largos (MAPA). Algunos aspectos en la medición de la PA pueden interferir en la obtención de resultados confiables y, en consecuencia, causar daños en las decisiones a tomar. Estos incluyen la importancia de usar valores promedio, la variación de la PA durante el día y la variabilidad a corto plazo. Estos aspectos han alentado la realización de un mayor número de mediciones en diversas situaciones, y diferentes pautas han abogado por el uso de equipos que promuevan estas acciones. Los dispositivos que realizan MRPA o MAPA, que además de permitir una mayor precisión, cuando se usan juntos, detectan la hipertensión de bata blanca (HBB), la hipertensión enmascarada (HM), las alteraciones de la PA durante el sueño y la hipertensión resistente (HR) (definida en el Capítulo 2 de esta guía), están ganando cada vez más importancia. Teniendo en cuenta estos detalles, debemos enfatizar que la información relacionada con el diagnóstico, la clasificación y el establecimiento de objetivos todavía se basa en la medición de la presión arterial en el consultorio, y por esta razón, se debe prestar toda la atención a la ejecución adecuada de este procedimiento.A hipertensão arterial (HA) é um dos principais fatores de risco modificáveis para morbidade e mortalidade em todo o mundo, sendo um dos maiores fatores de risco para doença arterial coronária, acidente vascular cerebral (AVC) e insuficiência renal. Além disso, é altamente prevalente e atinge mais de um terço da população mundial. A medida da PA é procedimento OBRIGATÓRIO em qualquer atendimento médico ou realizado por diferentes profissionais de saúde. Contudo, ainda é comumente realizada sem os cuidados técnicos necessários. Como o diagnóstico se baseia na medida da PA, fica claro o cuidado que deve haver com as técnicas, os métodos e os equipamentos utilizados na sua realização. Deve-se reforçar que, feito o diagnóstico, toda a investigação e os tratamentos de curto, médio e longo prazos são feitos com base nos resultados da medida da PA. Assim, técnicas e/ou equipamentos inadequados podem levar a diagnósticos incorretos, tanto subestimando quanto superestimando valores e levando a condutas inadequadas e grandes prejuízos à saúde e à economia das pessoas e das nações. Uma vez feito o diagnóstico correto, na medida em que avança o conhecimento da importância do tratamento adequado, com a adoção de valores de normalidade mais detalhados e com objetivos de tratamento mais cuidadosos no sentido do alcance de metas de PA mais rigorosas, fica também reforçada a importância da precisão na medida da PA. A medida da PA (descrita a seguir) é habitualmente feita pelo método tradicional, a assim chamada medida casual ou de consultório. Ao longo do tempo, foram agregadas alternativas a ela, mediante o uso de equipamentos semiautomáticos ou automáticos pelo próprio paciente, nas salas de espera ou fora do consultório, em sua própria residência ou em espaços públicos. Um passo adiante foi dado com o uso de equipamentos semiautomáticos providos de memória que permitem medidas sequenciais fora do consultório (AMPA; ou MRPA) e outros automáticos que permitem medidas programadas por períodos mais prolongados (MAPA). Alguns aspectos na medida da PA podem interferir na obtenção de resultados fidedignos e, consequentemente, causar prejuízo nas condutas a serem tomadas. Entre eles, estão: a importância de serem utilizados valores médios, a variação da PA durante o dia e a variabilidade a curto prazo. Esses aspectos têm estimulado a realização de maior número de medidas em diversas situações, e as diferentes diretrizes têm preconizado o uso de equipamentos que favoreçam essas ações. Ganham cada vez mais espaço os equipamentos que realizam MRPA ou MAPA, que, além de permitirem maior precisão, se empregados em conjunto, detectam a HA do avental branco (HAB), HA mascarada (HM), alterações da PA no sono e HA resistente (HAR) (definidos no Capítulo 2 desta diretriz). Resguardados esses detalhes, devemos ressaltar que as informações relacionadas a diagnóstico, classificação e estabelecimento de metas ainda são baseadas na medida da PA de consultório e, por esse motivo, toda a atenção deve ser dada à realização desse procedimento
    corecore