2,531 research outputs found
Electronics implementation of the solar neutron experiment
The electronic equipment design and function are discussed for the solar neutron counter experiment. Circuit diagrams are included
A large area detector for neutrons between 2 and 100 MeV
A neutron detector sensitive from 2 to 100 MeV is described. The detector is designed for high altitude balloon flight to measure the flux, energy and direction of albedo neutrons from the earth and to search for solar neutrons. A neutron scatter from a proton is required in each of two liquid scintillator tanks spaced 1 meter apart. The energy of the recoil proton in the first tank is obtained from pulse height analysis of the scintillator output. The energy of the recoil neutron is obtained from its time of flight between the tanks. The detector has been calibrated with 15.3 MeV neutrons and mu mesons. The minimum detectable flux is 10(-4) neutron/sq cm/sec at a counting rate of one per minute; the energy resolution is 12% at 15 MeV and 30% at 100 MeV. The angle between the incoming neutron and the recoil neutron is measured to + or - 10 deg
Analysis of electromagnetic interference from power system processing and transmission components for Space Station Freedom
The goal of this research project was to analyze the potential effects of electromagnetic interference (EMI) originating from power system processing and transmission components for Space Station Freedom. The approach consists of four steps: (1) developing analytical tools (models and computer programs); (2) conducting parameterization (what if?) studies; (3) predicting the global space station EMI environment; and (4) providing a basis for modification of EMI standards
Ozone loss derived from balloon-borne tracer measurements in the 1999/2000 Arctic winter
Balloon-borne measurements of CFC11 (from the DIRAC in situ gas chromatograph and the DESCARTES grab sampler), ClO and O3 were made during the 1999/2000 Arctic winter as part of the SOLVE-THESEO 2000 campaign, based in Kiruna (Sweden). Here we present the CFC11 data from nine flights and compare them first with data from other instruments which flew during the campaign and then with the vertical distributions calculated by the SLIMCAT 3D CTM. We calculate ozone loss inside the Arctic vortex between late January and early March using the relation between CFC11 and O3 measured on the flights. The peak ozone loss (~1200ppbv) occurs in the 440-470K region in early March in reasonable agreement with other published empirical estimates. There is also a good agreement between ozone losses derived from three balloon tracer data sets used here. The magnitude and vertical distribution of the loss derived from the measurements is in good agreement with the loss calculated from SLIMCAT over Kiruna for the same days
IllustrisTNG and S2COSMOS: possible conflicts in the evolution of neutral gas and dust
We investigate the evolution in galactic dust mass over cosmic time through (i) empirically derived dust masses using stacked submillimetre fluxes at 850 μm in the COSMOS field and (ii) dust masses derived using a robust post-processing method on the results from the cosmological hydrodynamical simulation IllustrisTNG. We effectively perform a ‘self-calibration’ of the dust mass absorption coefficient by forcing the model and observations to agree at low redshift and then compare the evolution shown by the observations with that predicted by the model. We create dust mass functions (DMFs) based on the IllustrisTNG simulations from 0 < z < 0.5 and compare these with previously observed DMFs. We find a lack of evolution in the DMFs derived from the simulations, in conflict with the rapid evolution seen in empirically derived estimates of the low-redshift DMF. Furthermore, we observe a strong evolution in the observed mean ratio of dust mass to stellar mass of galaxies over the redshift range 0 < z < 5, whereas the corresponding dust masses from IllustrisTNG show relatively little evolution, even after splitting the sample into satellites and centrals. The large discrepancy between the strong observed evolution and the weak evolution predicted by IllustrisTNG plus post-processing may be explained by either strong cosmic evolution in the properties of the dust grains or limitations in the model. In the latter case, the limitation may be connected to previous claims that the neutral gas content of galaxies does not evolve fast enough in IllustrisTNG
Lidar System Model for Use With Path Obscurants and Experimental Validation
When lidar pulses travel through a short path that includes a relatively high concentration of aerosols, scattering phenomena can alter the power and temporal properties of the pulses significantly, causing undesirable effects in the received pulse. In many applications the design of the lidar transmitter and receiver must consider adverse environmental aerosol conditions to ensure the desired performance. We present an analytical model of lidar system operation when the optical path includes aerosols for use in support of instrument design, simulations, and system evaluation. The model considers an optical path terminated with a solid object, although it can also be applied, with minor modifications, to cases where the expected backscatter occurs from nonsolid objects. The optical path aerosols are characterized by their attenuation and backscatter coefficients derived by the Mie theory from the concentration and particle size distribution of the aerosol. Other inputs include the lidar system parameters and instrument response function, and the model output is the time-resolved received pulse. The model is demonstrated and experimentally validated with military fog oil smoke for short ranges (several meters). The results are obtained with a lidar system operating at a wavelength of 0.905 μm within and outside the aerosol. The model goodness of fit is evaluated using the statistical coefficient of determination whose value ranged from 0.88 to 0.99 in this study
Effect of rejection on electrophysiologic function of canine intestinal grafts: Correlation with histopathology and na-k-ATPase activity
To investigate whether electrophysiologic changes can detect the early onset and progress of intestinal rejection, changes in in vitro electrophysiologic function, intestinal histopathology, and Na-K-ATPase activity were studied in dogs. Adult mongrel dogs of both sexes, weighing 18-24 kg, were used for auto and allo small bowel transplantation. The entire small bowels, except for short segments at the proximal and distal ends, were snitched between a pair of dogs (allograft). Animals receiving intestinal autotransplantation were used as controls. AIIograji recipients were sacrificed 3, 4, 5, 7, or 9 days after transplantation, and autograft recipients were sacrificed 3, 7, or 14 days afier transplantation. Immunosuppression was not used. Electrophysiologic measurements were done with an Ussing chamber. Histological analysis was performed blindly using whole thickness sections. Na-K-ATPase activity in the mucosal tissue, which is said to regulate the potential difference, was also measured. Potential difference, resistance, and Na-K-ATPase activity of the allografi intestine decreased with time and were significantly lower 7 and 9 days after transplantation compared to host intestine, normul intestine, and graft intestine of controls (autograft). Potential difference, resistance, and Na-K-ATPase activity of the native intestinal tissue and the autografts did not decrease with time. Detection of histologically mild rejection of the intestine, which is important for appropriate immunosup-pressive treatment in clinical cases, could not be achieved based on electrophysiology or Na-K-ATPase activity. Deterioration of electrophysiologic function during rejection correlated with the histological rejection process and Na-K-ATPase activity; however, electrophysiology my not be a reliable tool for monitoring grafrs, since it cannot detect early intestinal rejection. © 1995 Informa UK Ltd All rights reserved: reproduction in whole or part not permitted
Primary synovial chondromatosis: an elemental investigation of a rare skeletal pathology
Background: Primary synovial chondromatosis (PSC) is a rare idiopathic pathology characterized by the formation of osseocartilaginous nodules within synovial joints, tendons, or bursae. The mineralization pattern of PSC nodules is poorly understood and has yet to be investigated using elemental analysis. Mapping this pattern could elucidate the progression of the disease.
Materials and methods: PSC nodules discovered during dissection of a formalin fixed donor were analyzed. Scanning electron microscopy paired with energy dispersive X-ray spectroscopy (SEM-EDS) was used to quantify calcium and phosphorus levels to distinguish mineralized components from cartilage, indicated by increased carbon and oxygen concentrations.
Results: Nine nodules with average dimensions 1.76cm x 1.25cm were identified in the semimembranosus bursa. SEM-EDS demonstrated increased calcium phosphate levels in nodular cores, while outer margins contained primarily carbon and oxygen. Quantification of these elements revealed nodular peripheries to contain 68.0% carbon, 30.2% oxygen, 0.8% calcium, and 1.0% phosphate, while cores were comprised of 38.1% carbon, 42.1% oxygen, 14.1% calcium, and 5.7% phosphate.
Conclusions: Nodules were found to have mineralized cores embedded within a cartilaginous matrix. This pattern suggests disease progression is facilitated by endochondral ossification, opening the potential for new therapeutic techniques
Ozone loss derived from balloon-borne tracer measurements and the SLIMCAT CTM
Balloon-borne measurements of CFC-11 (on flights of the DIRAC in situ gas chromatograph and the DESCARTES grab sampler), ClO and O3 were made during the 1999/2000 winter as part of the SOLVE-THESEO 2000 campaign. Here we present the CFC-11 data from nine flights and compare them first with data from other instruments which flew during the campaign and then with the vertical distributions calculated by the SLIMCAT 3-D CTM. We calculate ozone loss inside the Arctic vortex between late January and early March using the relation between CFC-11 and O3 measured on the flights, the peak ozone loss (1200 ppbv) occurs in the 440–470 K region in early March in reasonable agreement with other published empirical estimates. There is also a good agreement between ozone losses derived from three independent balloon tracer data sets used here. The magnitude and vertical distribution of the loss derived from the measurements is in good agreement with the loss calculated from SLIMCAT over Kiruna for the same days
- …