49 research outputs found

    Angiographic predictors of recurrence of restenosis after Wiktor stent implantation in native coronary arteries

    Get PDF
    Intracoronary stenting has been proposed as an adjunct to balloon angioplasty to improve the immediate and long-term results. However, late luminal narrowing has been reported following the implantation of a variety of stents. One of the studies conducted with the Wiktor stent is a prospective registry designed to evaluate the feasibility, safety and efficacy of elective stent implantation in patients with documented restenosis of a native coronary artery. To identify angiographic variables predicting recurrence of restenosis, the angiograms of the first 91 patients with successful stent implantation and without clinical evidence of (sub)acute thrombotic stent occlusion were analyzed with the Computer Assisted Angiographic Analysis System using automated edge detection. The incidence of restenosis was 44% by patient and 45% by stent according to the 0.72 mm criterion, and 30% by patient and 29% by stent according to the 50% diameter stenosis criterion. The risk for restenosis for several angiographic variables was determined using an univariate analysis and is expressed as odds ratio with corresponding confidence interval. The only statistically significant predictor of restenosis was the relative gain when it exceeded 0.48 using the 0.72 mm criterion (odds ratio 2.7, 95% confidence interval 1.1-6.4). Furthermore, the relation between the relative gain (increase in minimal luminal diameter normalized to vessel size) as angiographic index of vessel wall injury and relative loss (decrease in minimal luminal diameter normalized to vessel size) as index of neointimal thickening was analyzed using a linear regression analysis. When using the categorical approach to address restenosis, there is an increased risk for recurrent restenosis when the relative gain exceeds 0.48. The continuous approach underscores this concept by indicating a weak but positive relation between the relative gain and relative loss

    Recoil following Wiktor stent implantation for restenotic lesions of coronary arteries

    Get PDF
    The purpose of this study was to determine acute recoil of the vessel wall immediately after Wiktor stent implantation in native coronary arteries of 77 consecutive patients and to assess whether there was compression or “late recoil” of the stent itself at long-term follow-up. Furthermore, the relationship between recoil and a number of clinical, angiographic, and procedural variables was studied in addition to the relation between acute recoil renarrowing or restenosis was assessed. All angiograms were analyzed with the Cardiovascular Angiography Analysis System using automated edge detection. Acute recoil was defined by the difference between the mean diameter of the fully expanded balloon on which the stent was mounted and the mean diameter of the stented segment. Late recoil was calculated by comparing the mean diameter of the stent itself immediately after implantation and at follow-up without opacification of the vessel. Acute recoil amounted to 0.25 ± 0.32 mm or 8.2%. Multivariate analysis identified sex (coefficient = –0.20, p = 0.04) and stent/artery ratio (coefficient = 0.99, p = 0.0001) as the only independent predictors of acute recoil. “Late recoil” of the stent itself was not observed. The overall difference between the mean diameter of the stent itself immediately after implantation and at follow-up was –0.15 ± 0.33 mm, suggesting an overall increase in diameter of 5.0%. There was no relation between acute recoil and late restenosis. On the contrary, there was a trend towards a greater degree of recoil in patients without restenosis. Moreover, linear regression analysis disclosed a weak but negative correlation between acute recoil and a loss in minimal luminal diameter (coefficient: –0.55, p = 0.04). The Wiktor stent effectively scaffolds the instrumented vessel. Only a minimal amount of acute recoil was noted, which did not contribute to late luminal renarrowing or restenosis. In addition, no late compression of the stent itself was observed. These data suggest that tissue ingrowth into the lumen of the stented segment is the main cause of late luminal renarrowing after stent implantation. © 1994 Wiley-Liss,Inc.

    Optical Microscopy in the Nano-World

    Get PDF
    Scanning near-field optical microscopy (SNOM) is an optical microscopy whose resolution is not bound to the diffraction limit. It provides chemical information based upon spectral, polarization and/or fluorescence contrast images. Details as small as 20 nm can be recognized. Photophysical and photochemical effects can be studied with SNOM on a similar scale. This article reviews a good deal of the experimental and theoretical work on SNOM in Switzerland

    Serologic Reactivity Reflects Clinical Expression of Ulcerative Colitis in Children

    Get PDF
    Background In contrast to pediatric Crohn's disease (CD), little is known in pediatric ulcerative colitis (UC) about the relationship between disease phenotype and serologic reactivity to microbial and other antigens. Aim The aim of this study was to examine disease phenotype and serology in a well-characterized inception cohort of children newly diagnosed with UC during the PROTECT Study (Predicting Response to Standardized Pediatric Colitis Therapy). Methods Patients were recruited from 29 participating centers. Demographic, clinical, laboratory, and serologic (pANCA, ASCA IgA/IgG, Anti-CBir1, and Anti-OmpC) data were obtained from children 4-17 years old with UC. Results Sixty-five percent of the patients had positive serology for pANCA, with 62% less than 12 years old and 66% 12 years old or older. Perinuclear anti-neutrophil cytoplasmic antibodies did not correspond to a specific phenotype though pANCA ò100, found in 19%, was strongly associated with pancolitis (P = 0.003). Anti-CBir1 was positive in 19% and more common in younger children with 32% less than 12 years old as compared with 14% 12 years old or older (P < 0.001). No association was found in any age group between pANCA and Anti-CBir1. Relative rectal sparing was more common in +CBir1, 16% versus 7% (P = 0.02). Calprotectin was lower in Anti-CBir1+ (Median [IQR] 1495 mcg/g [973-3333] vs 2648 mcg/g [1343-4038]; P = 0.04). Vitamin D 25-OH sufficiency was associated with Anti-CBir1+ (P = 0.0009). Conclusions The frequency of pANCA in children was consistent with adult observations. High titer pANCA was associated with more extensive disease, supporting the idea that the magnitude of immune reactivity may reflect disease severity. Anti-CBir1+ was more common in younger ages, suggesting host-microbial interactions may differ by patient age

    Morphologic change in coronary artery stenosis with the Medtronic Wiktor Stent: initial results from the core laboratory for quantitative angiography

    No full text
    The purpose of this study was to assess the early changes in stenosis geometry after implantation of the Medtronic Wiktor stent in human coronary arteries. Morphologic changes were evaluated by quantitative coronary angiography using automated edge detection. The hemodynamic significance of the morphologic changes were assessed by the calculation of the theoretical pressure drop across the dilated and stented stenosis derived from the Poiseuile and turbulent resistances assuming a coronary blood flow of either 0.5, 1, or 3 ml/sec. Fifty patients were studied before and immediately after stent implantation. The stented coronary artery was the left anterior descending artery in 26 patients, the circumflex artery in eight patients, and the right coronary artery in 16 patients. Stent implantation resulted in an additional increase in the minimal luminal cross-sectional area and minimal luminal diameter of the dilated vessel without changing the curvature of the stenosis. Furthermore, there was a significant reduction of the "plaque area." This was associated with a normali

    Gradient of electro-convulsive therapy's antidepressant effects along the longitudinal hippocampal axis.

    Get PDF
    Despite decades of successful treatment of therapy-resistant depression and major scientific advances in the field, our knowledge about electro-convulsive therapy's (ECT) mechanisms of action is still scarce. Building on strong empirical evidence for ECT-induced hippocampus anatomy changes, we sought to test the hypothesis that ECT has a differential impact along the hippocampus longitudinal axis. We acquired behavioural and brain anatomy magnetic resonance imaging (MRI) data in patients with depressive episode undergoing ECT (n = 9) or pharmacotherapy (n = 24) and healthy controls (n = 30) at two time points 3 months apart. Using whole-brain voxel-based statistical parametric mapping and topographic analysis focused on the hippocampus, we observed ECT-induced gradient of grey matter volume increase along the hippocampal longitudinal axis with predominant impact on its anterior portion. Clinical outcome measures showed strong correlations with both baseline volume and rate of ECT-induced change exclusively for the anterior, but not posterior hippocampus. We interpret our findings confined to the anterior hippocampus and amygdala as additional evidence of the regional specific impact of ECT that unfolds its beneficial effect on depression via the "limbic" system. Main limitations of the study are patients' polypharmacy, heterogeneity of psychiatric diagnosis, and long-time interval between scans
    corecore