7,141 research outputs found

    An EXPRESS Rack Overview and Support for Microgravity Research on the International Space Station (ISS)

    Get PDF
    The EXpedite the PRocessing of Experiments to Space Station or EXPRESS Rack System has provided accommodations and facilitated operations for microgravity-based research payloads for over 6 years on the International Space Station (ISS). The EXPRESS Rack accepts Space Shuttle middeck type lockers and International Subrack Interface Standard (ISIS) drawers, providing a modular-type interface on the ISS. The EXPRESS Rack provides 28Vdc power, Ethernet and RS-422 data interfaces, thermal conditioning, vacuum exhaust, and Nitrogen supply for payload use. The EXPRESS Rack system also includes payload checkout capability with a flight rack or flight rack emulator prior to launch, providing a high degree of confidence in successful operations once an-orbit. In addition, EXPRESS trainer racks are provided to support crew training of both rack systems and subrack operations. Standard hardware and software interfaces provided by the EXPRESS Rack simplify the integration processes for ISS payload development. The EXPRESS Rack is designed to accommodate multidiscipline research, allowing for the independent operation of each subrack payload within a single rack. On-orbit operations began for the EXPRESS Rack Project on April 24, 2001, with one rack operating continuously to support high-priority payloads. The other on-orbit EXPRESS Racks operate based on payload need and resource availability. Over 50 multi-discipline payloads have now been supported on-orbit by the EXPRESS Rack Program. Sustaining engineering, logistics, and maintenance functions are in place to maintain hardware, operations and provide software upgrades. Additional EXPRESS Racks are planned for launch prior to ISS completion in support of long-term operations and the planned transition of the U.S. Segment to a National Laboratory

    Sex differences in exercise-induced diaphragmatic fatigue in endurance-trained athletes

    Get PDF
    There is evidence that female athletes may be more susceptible to exercise-induced arterial hypoxemia and expiratory flow limitation and have greater increases in operational lung volumes during exercise relative to men. These pulmonary limitations may ultimately lead to greater levels of diaphragmatic fatigue in women. Accordingly, the purpose of this study was to determine whether there are sex differences in the prevalence and severity of exercise-induced diaphragmatic fatigue in 38 healthy endurance-trained men (n = 19; maximal aerobic capacity = 64.0 ± 1.9 ml·kg–1·min–1) and women (n = 19; maximal aerobic capacity = 57.1 ± 1.5 ml·kg–1·min–1). Transdiaphragmatic pressure (Pdi) was calculated as the difference between gastric and esophageal pressures. Inspiratory pressure-time products of the diaphragm and esophagus were calculated as the product of breathing frequency and the Pdi and esophageal pressure time integrals, respectively. Cervical magnetic stimulation was used to measure potentiated Pdi twitches (Pdi,tw) before and 10, 30, and 60 min after a constant-load cycling test performed at 90% of peak work rate until exhaustion. Diaphragm fatigue was considered present if there was a 15% reduction in Pdi,tw after exercise. Diaphragm fatigue occurred in 11 of 19 men (58%) and 8 of 19 women (42%). The percent drop in Pdi,tw at 10, 30, and 60 min after exercise in men (n = 11) was 30.6 ± 2.3, 20.7 ± 3.2, and 13.3 ± 4.5%, respectively, whereas results in women (n = 8) were 21.0 ± 2.1, 11.6 ± 2.9, and 9.7 ± 4.2%, respectively, with sex differences occurring at 10 and 30 min (P < 0.05). Men continued to have a reduced contribution of the diaphragm to total inspiratory force output (pressure-time product of the diaphragm/pressure-time product of the esophagus) during exercise, whereas diaphragmatic contribution in women changed very little over time. The findings from this study point to a female diaphragm that is more resistant to fatigue relative to their male counterparts

    The orientation-preserving diffeomorphism group of S^2 deforms to SO(3) smoothly

    Full text link
    Smale proved that the orientation-preserving diffeomorphism group of S^2 has a continuous strong deformation retraction to SO(3). In this paper, we construct such a strong deformation retraction which is diffeologically smooth.Comment: 16 page

    Reconstituting ring-rafts in bud-mimicking topography of model membranes.

    Get PDF
    During vesicular trafficking and release of enveloped viruses, the budding and fission processes dynamically remodel the donor cell membrane in a protein- or a lipid-mediated manner. In all cases, in addition to the generation or relief of the curvature stress, the buds recruit specific lipids and proteins from the donor membrane through restricted diffusion for the development of a ring-type raft domain of closed topology. Here, by reconstituting the bud topography in a model membrane, we demonstrate the preferential localization of cholesterol- and sphingomyelin-enriched microdomains in the collar band of the bud-neck interfaced with the donor membrane. The geometrical approach to the recapitulation of the dynamic membrane reorganization, resulting from the local radii of curvatures from nanometre-to-micrometre scales, offers important clues for understanding the active roles of the bud topography in the sorting and migration machinery of key signalling proteins involved in membrane budding

    Total Ionizing Dose Tolerance of Micro-SD Cards for Small Satellite Missions

    Get PDF
    Tests have determined damage thresholds and failure rates as a function of total ionizing dose (TID) of beta radiation for various types of COTS micro-SD cards commonly used for memory storage in space applications. Radiation tolerance of high-density electronics are common critical failure modes for satellites, particularly for small satellites that often use lower shielding and less radiation-hardened COTS components. The tests evaluated SD-card formatting and read/write speeds at nine radiation intervals for up to ~ 1000 Gy TID, equivalent to ~15 times TID typically experienced annually on the unshielded exterior of satellites in Low Earth Orbit. A limited number of failures were observed beginning after ~ 400 Gy TID. Cards experiencing failures were subsequently tested at more rapid interval intervals, and typically recovered their initial read/write speeds after ≀ 24 hrs, except in more severe cases after \u3e 400 Gy TID. These results will facilitate satellite designers’ selection of the appropriate quality and cost of the micro-SD cards for their particular mission, based on reliability and radiation tolerance

    Discrepancies in East Asians' perceived actual and ideal phenotypic facial features

    Get PDF
    The present study tested for the existence of a phenotypic actual-ideal discrepancy in East Asians’ appraisals of their own faces, in the direction of idealizing a phenotypically “Whiter” face than they perceived themselves to have. The study was conducted in two phases. In the first phase, East Asian participants residing in the U.S. (N = 104; Mage = 18.73) came into the lab to have their photograph taken. They were sent a link to complete the second phase online. Participants were required to recall either their previous day, an experience of racial discrimination, or an experience of racial acceptance. They then selected their actual and ideal face from an array of faces comprising their actual face and eight variants of their face that had been transformed to look phenotypically more “White” or more “East Asian”. A robust actual-ideal discrepancy emerged: participants both idealized a phenotypically “Whiter” face and perceived themselves as having a more phenotypically “East Asian” face than they objectively did. This discrepancy arose irrespective of whether participants were reminded of an incident of racial discrimination or acceptance

    Mass fluxes and isofluxes of methane (CH4) at a New Hampshire fen measured by a continuous wave quantum cascade laser spectrometer

    Get PDF
    We have developed a mid‐infrared continuous‐wave quantum cascade laser direct‐absorption spectrometer (QCLS) capable of high frequency (≄1 Hz) measurements of 12CH4 and 13CH4 isotopologues of methane (CH4) with in situ 1‐s RMS image precision of 1.5 ‰ and Allan‐minimum precision of 0.2 ‰. We deployed this QCLS in a well‐studied New Hampshire fen to compare measurements of CH4 isoflux by eddy covariance (EC) to Keeling regressions of data from automated flux chamber sampling. Mean CH4 fluxes of 6.5 ± 0.7 mg CH4 m−2 hr−1 over two days of EC sampling in July, 2009 were indistinguishable from mean autochamber CH4 fluxes (6.6 ± 0.8 mgCH4 m−2 hr−1) over the same period. Mean image composition of emitted CH4 calculated using EC isoflux methods was −71 ± 8 ‰ (95% C.I.) while Keeling regressions of 332 chamber closing events over 8 days yielded a corresponding value of −64.5 ± 0.8 ‰. Ebullitive fluxes, representing ∌10% of total CH4 fluxes at this site, were on average 1.2 ‰ enriched in 13C compared to diffusive fluxes. CH4 isoflux time series have the potential to improve process‐based understanding of methanogenesis, fully characterize source isotopic distributions, and serve as additional constraints for both regional and global CH4 modeling analysis
    • 

    corecore