34 research outputs found
Vicarious experience affects patients' treatment preferences for depression
Purpose: Depression is common in primary care but often under-treated. Personal experiences with depression can affect adherence to therapy, but the effect of vicarious experience is unstudied. We sought to evaluate the association between a patient's vicarious experiences with depression (those of friends or family) and treatment preferences for depressive symptoms. Methods: We sampled 1054 English and/or Spanish speaking adult subjects from July through December 2008, randomly selected from the 2008 California Behavioral Risk Factor Survey System, regarding depressive symptoms and treatment preferences. We then constructed a unidimensional scale using item analysis that reflects attitudes about antidepressant pharmacotherapy. This became the dependent variable in linear regression analyses to examine the association between vicarious experiences and treatment preferences for depressive symptoms. Results: Our sample was 68% female, 91% white, and 13% Hispanic. Age ranged from 18-94 years. Mean PHQ-9 score was 4.3; 14.5% of respondents had a PHQ-9 score >9.0, consistent with active depressive symptoms. Analyses controlling for current depression symptoms and socio-demographic factors found that in patients both with (coefficient 1.08, p = 0.03) and without (coefficient 0.77, p = 0.03) a personal history of depression, having a vicarious experience (family and friend, respectively) with depression is associated with a more favorable attitude towards antidepressant medications. Conclusions: Patients with vicarious experiences of depression express more acceptance of pharmacotherapy. Conversely, patients lacking vicarious experiences of depression have more negative attitudes towards antidepressants. When discussing treatment with patients, clinicians should inquire about vicarious experiences of depression. This information may identify patients at greater risk for non-adherence and lead to more tailored patient-specific education about treatment
Search for annual and diurnal rate modulations in the LUX experiment
Various dark matter models predict annual and diurnal modulations of dark matter interaction rates in Earth-based experiments as a result of the Earth’s motion in the halo. Observation of such features can provide generic evidence for detection of dark matter interactions. This paper reports a search for both annual and diurnal rate modulations in the LUX dark matter experiment using over 20 calendar months of data acquired between 2013 and 2016. This search focuses on electron recoil events at low energies, where leptophilic dark matter interactions are expected to occur and where the DAMA experiment has observed a strong rate modulation for over two decades. By using the innermost volume of the LUX detector and developing robust cuts and corrections, we obtained a stable event rate of 2.3±0.2  cpd/keVee/tonne, which is among the lowest in all dark matter experiments. No statistically significant annual modulation was observed in energy windows up to 26  keVee. Between 2 and 6  keVee, this analysis demonstrates the most sensitive annual modulation search up to date, with 9.2σ tension with the DAMA/LIBRA result. We also report no observation of diurnal modulations above 0.2  cpd/keVee/tonne amplitude between 2 and 6  keVee.Various dark matter models predict annual and diurnal modulations of dark matter interaction rates in Earth-based experiments as a result of the Earth's motion in the halo. Observation of such features can provide generic evidence for detection of dark matter interactions. This paper reports a search for both annual and diurnal rate modulations in the LUX dark matter experiment using over 20 calendar months of data acquired between 2013 and 2016. This search focuses on electron recoil events at low energies, where leptophilic dark matter interactions are expected to occur and where the DAMA experiment has observed a strong rate modulation for over two decades. By using the innermost volume of the LUX detector and developing robust cuts and corrections, we obtained a stable event rate of 2.30.2~cpd/keV/tonne, which is among the lowest in all dark matter experiments. No statistically significant annual modulation was observed in energy windows up to 26~keV. Between 2 and 6~keV, this analysis demonstrates the most sensitive annual modulation search up to date, with 9.2 tension with the DAMA/LIBRA result. We also report no observation of diurnal modulations above 0.2~cpd/keV/tonne amplitude between 2 and 6~keV
Measurement of the gamma ray background in the Davis Cavern at the Sanford Underground Research Facility
Deep underground environments are ideal for low background searches due to the attenuation of cosmic rays by passage through the earth. However, they are affected by backgrounds from γ-rays emitted by 40K and the 238U and 232Th decay chains in the surrounding rock. The LUX-ZEPLIN (LZ) experiment will search for dark matter particle interactions with a liquid xenon TPC located within the Davis campus at the Sanford Underground Research Facility, Lead, South Dakota, at the 4,850-foot level. In order to characterise the cavern background, in-situ γ-ray measurements were taken with a sodium iodide detector in various locations and with lead shielding. The integral count rates (0--3300~keV) varied from 596~Hz to 1355~Hz for unshielded measurements, corresponding to a total flux in the cavern of 1.9±0.4~γ cm−2s−1. The resulting activity in the walls of the cavern can be characterised as 220±60~Bq/kg of 40K, 29±15~Bq/kg of 238U, and 13±3~Bq/kg of 232Th
The design, implementation, and performance of the LZ calibration systems
LUX-ZEPLIN (LZ) is a tonne-scale experiment searching for direct dark matter interactions and other rare events. It is located at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, USA. The core of the LZ detector is a dual-phase xenon time projection chamber (TPC), designed with the primary goal of detecting Weakly Interacting Massive Particles (WIMPs) via their induced low energy nuclear recoils. Surrounding the TPC, two veto detectors immersed in an ultra-pure water tank enable reducing background events to enhance the discovery potential. Intricate calibration systems are purposely designed to precisely understand the responses of these three detector volumes to various types of particle interactions and to demonstrate LZ's ability to discriminate between signals and backgrounds. In this paper, we present a comprehensive discussion of the key features, requirements, and performance of the LZ calibration systems, which play a crucial role in enabling LZ's WIMP-search and its broad science program. The thorough description of these calibration systems, with an emphasis on their novel aspects, is valuable for future calibration efforts in direct dark matter and other rare-event search experiments
New constraints on ultraheavy dark matter from the LZ experiment
Searches for dark matter with liquid xenon time projection chamber experiments have traditionally focused on the region of the parameter space that is characteristic of weakly interacting massive particles, ranging from a few GeV/c2 to a few TeV/c2. Models of dark matter with a mass much heavier than this are well motivated by early production mechanisms different from the standard thermal freeze-out, but they have generally been less explored experimentally. In this work, we present a reanalysis of the first science run of the LZ experiment, with an exposure of 0.9  tonne×yr, to search for ultraheavy particle dark matter. The signal topology consists of multiple energy deposits in the active region of the detector forming a straight line, from which the velocity of the incoming particle can be reconstructed on an event-by-event basis. Zero events with this topology were observed after applying the data selection calibrated on a simulated sample of signal-like events. New experimental constraints are derived, which rule out previously unexplored regions of the dark matter parameter space of spin-independent interactions beyond a mass of 1017  GeV/c2.
Published by the American Physical Society
2024
</jats:sec