33 research outputs found

    THE INVESTMENT CLIMATE IN 16 INDIAN STATES

    Get PDF
    In this paper, the author attempts to identify the characteristics of the business climate in India that can help explain the different performance of individual states in terms of investment and growth. The paper develops a new Investment Climate Index aimed at summarizing the aspects of the business environment that entrepreneurs consider when deciding whether to invest. Using this index, the author explores the investment climate in several typologies of Indian states and identify the key features of a poor business environment in India. The analysis shows that infrastructure and institutions remain the main bottlenecks in the country's private sector development. More specifically, power, transportation, corruption, tax regulations, and theft are major factors explaining the poor business environment in some Indian states. Infrastructure appears to be the single most important constraint, as it is particularly binding in states that show low levels of domestic investment and GDP growth.affiliated organizations; bank financing; bottlenecks; business climate; business environment; business regulations; collateral; Cost of finance; data availability; domestic investment;

    Nigeria 2011

    Get PDF
    This investment climate analysis reviews the experiences of over 3000 surveyed business owners in 26 states of Nigeria about the aspects of the business climate that affect their businesses. It complements a similar study in 2007 that covered 11 other Nigerian states. The survey asks business owners about both their perceptions and the actual costs of selected constraints. The analysis benchmarks Nigeria against comparator countries, and provides detailed data for each state. Nigerian firms have low productivity, as measured by their output in relation to their labor and capital inputs. Firms in Kenya are about 40 percent more efficient, firms in Russia almost twice as productive, and firms in South Africa almost four times as productive. Nigerian firms that export are about 90 percent more productive than non-exporters. Although labor in Nigeria is inexpensive, it is not inexpensive enough to compensate for this low productivity. The poor performance of Nigerian firms reflects many factors. This study focuses on constraints in the business climate and the serious costs they impose on Nigerian firms. Taken together, the total indirect costs of poor quality infrastructure, crime and security, and corruption amount to over 10 percent of sales for Nigerian firms. This is twice as high as in South Africa, Brazil, Russia and Indonesia. Microenterprises firms with fewer than five workers face similar constraints as larger firm's unreliable power, limited access to finance, corruption, and transportation bottlenecks. But the consequences for their businesses are far more severe. For instance, most microenterprises cannot afford generators, so power outages are more likely to shut down their operation. Lacking collateral, almost no microenterprises have access to formal external financing. Document type: Boo

    Hyperbolic Meta-Antennas Enable Full Control of Scattering and Absorption of Light

    Get PDF
    We introduce a novel concept of hybrid metal-dielectric meta-antenna supporting type II hyperbolic dispersion, which enables full control of absorption and scattering of light in the visible/near-infrared spectral range. This ability lies in the different nature of the localized hyperbolic Bloch-like modes excited within the meta-antenna. The experimental evidence is corroborated by a comprehensive theoretical study. In particular, we demonstrate that two main modes, one radiative and one non-radiative, can be excited by direct coupling with the free-space radiation. We show that the scattering is the dominating electromagnetic decay channel, when an electric dipolar mode is induced in the system, whereas a strong absorption process occurs when a magnetic dipole is excited. Also, by varying the geometry of the system, the relative ratio of scattering and absorption, as well as their relative enhancement and/or quenching, can be tuned at will over a broad spectral range, thus enabling full control of the two channels. Importantly, both radiative and nonradiative modes supported by our architecture can be excited directly with far-field radiation. This is observed to occur even when the radiative channels (scattering) are almost totally suppressed, thereby making the proposed architecture suitable for practical applications. Finally, the hyperbolic meta-antennas possess both angular and polarization independent structural integrity, unlocking promising applications as hybrid meta-surfaces or as solvable nanostructures

    An Extensive Quality Control and Quality Assurance (QC/QA) Program Significantly Improves Inter-Laboratory Concordance Rates of Flow-Cytometric Minimal Residual Disease Assessment in Acute Lymphoblastic Leukemia : An I-BFM-FLOW-Network Report

    Get PDF
    Monitoring of minimal residual disease (MRD) by flow cytometry (FCM) is a powerful prognostic tool for predicting outcomes in acute lymphoblastic leukemia (ALL). To apply FCM-MRD in large, collaborative trials, dedicated laboratory staff must be educated to concordantly high levels of expertise and their performance quality should be continuously monitored. We sought to install a unique and comprehensive training and quality control (QC) program involving a large number of reference laboratories within the international Berlin-Frankfurt-Münster (I-BFM) consortium, in order to complement the standardization of the methodology with an educational component and persistent quality control measures. Our QC and quality assurance (QA) program is based on four major cornerstones: (i) a twinning maturation program, (ii) obligatory participation in external QA programs (spiked sample send around, United Kingdom National External Quality Assessment Service (UK NEQAS)), (iii) regular participation in list-mode-data (LMD) file ring trials (FCM data file send arounds), and (iv) surveys of independent data derived from trial results. We demonstrate that the training of laboratories using experienced twinning partners, along with continuous educational feedback significantly improves the performance of laboratories in detecting and quantifying MRD in pediatric ALL patients. Overall, our extensive education and quality control program improved inter-laboratory concordance rates of FCM-MRD assessments and ultimately led to a very high conformity of risk estimates in independent patient cohorts.publishersversionPeer reviewe

    An Extensive Quality Control and Quality Assurance (QC/QA) Program Significantly Improves Inter-Laboratory Concordance Rates of Flow-Cytometric Minimal Residual Disease Assessment in Acute Lymphoblastic Leukemia: An I-BFM-FLOW-Network Report

    Get PDF
    Monitoring of minimal residual disease (MRD) by flow cytometry (FCM) is a powerful prognostic tool for predicting outcomes in acute lymphoblastic leukemia (ALL). To apply FCM-MRD in large, collaborative trials, dedicated laboratory staff must be educated to concordantly high levels of expertise and their performance quality should be continuously monitored. We sought to install a unique and comprehensive training and quality control (QC) program involving a large number of reference laboratories within the international Berlin-Frankfurt-Münster (I-BFM) consortium, in order to complement the standardization of the methodology with an educational component and persistent quality control measures. Our QC and quality assurance (QA) program is based on four major cornerstones: (i) a twinning maturation program, (ii) obligatory participation in external QA programs (spiked sample send around, United Kingdom National External Quality Assessment Service (UK NEQAS)), (iii) regular participation in list-mode-data (LMD) file ring trials (FCM data file send arounds), and (iv) surveys of independent data derived from trial results. We demonstrate that the training of laboratories using experienced twinning partners, along with continuous educational feedback significantly improves the performance of laboratories in detecting and quantifying MRD in pediatric ALL patients. Overall, our extensive education and quality control program improved inter-laboratory concordance rates of FCM-MRD assessments and ultimately led to a very high conformity of risk estimates in independent patient cohorts
    corecore