7 research outputs found

    Microprocessor controlled proof-mass actuator

    Get PDF
    The objective of the microprocessor controlled proof-mass actuator is to develop the capability to mount a small programmable device on laboratory models. This capability will allow research in the active control of flexible structures. The approach in developing the actuator will be to mount all components as a single unit. All sensors, electronic and control devices will be mounted with the actuator. The goal for the force output capability of the actuator will be one pound force. The programmable force actuator developed has approximately a one pound force capability over the usable frequency range, which is above 2 Hz

    Joint for a variable geometry truss and method of constructing same

    Get PDF
    A joint and a method of constructing a joint for a variable geometry truss having a variable number of planes of variable length battens connected together in a triangular configuration, each plane being connected by six fixed length longerons in a Stewart platform configuration, are presented. The variable length battens allow the orientation of one end plane of the variable geometry truss to be changed to the other end plane in a controlled manner by selectively adjusting the lengths of the variable length battens. A main pivot joint pivotally connects two battens about a pivotal axis. A universal joint is pivotally connected to the main joint such that the pivotal axis of the universal joint is coextensive with the pivotal axis at the main joint. Two longerons are pivotally connected to the universal joint. Each longeron is thereby provided with three intersecting axes of rotation. Each longeron may include a revolute joint, allowing rotation about the longitudinal axis of the longeron

    A survey of experiments and experimental facilities for active control of flexible structures

    Get PDF
    A brief survey of large space structure control related experiments and facilities was presented. This survey covered experiments performed before and up to 1982, and those of the present period (1982-...). Finally, the future planned experiments and facilities in support of the control-structure interaction (CSI) program were reported. It was stated that new, improved ground test facilities are needed to verify the new CSI design techniques that will allow future space structures to perform planned NASA missions

    Impact of Chlamydia trachomatis in the reproductive setting: British Fertility Society Guidelines for practice

    Get PDF
    Chlamydia trachomatis infection of the genital tract is the most common sexually transmitted infection and has a world-wide distribution. The consequences of infection have an adverse effect on the reproductive health of women and are a common cause of infertility. Recent evidence also suggests an adverse effect on male reproduction. There is a need to standardise the approach in managing the impact of C. trachomatis infection on reproductive health. We have surveyed current UK practice towards screening and management of Chlamydia infections in the fertility setting. We found that at least 90% of clinicians surveyed offered screening. The literature on this topic was examined and revealed a paucity of solid evidence for estimating the risks of long-term reproductive sequelae following lower genital tract infection with C. trachomatis. The mechanism for the damage that occurs after Chlamydial infections is uncertain. However, instrumentation of the uterus in women with C. trachomatis infection is associated with a high risk of pelvic inflammatory disease, which can be prevented by appropriate antibiotic treatment and may prevent infected women from being at increased risk of the adverse sequelae, such as ectopic pregnancy and tubal factor infertility. Recommendations for practice have been proposed and the need for further studies is identified

    A Cryogenic Magnetostrictive Actuator using a Persistent High Temperature Superconducting Magnet, Part 1: Concept and Design

    No full text
    Cryogenic magnetostrictive materials, such as rare earth zinc crystals, offer high strains and high forces with minimally applied magnetic fields, making the material ideally suited for deformable optics applications. For cryogenic temperature applications, such as Next Generation Space Telescope (NGST), the use of superconducting magnets offer the possibility of a persistent mode of operation, i.e., the magnetostrictive material will maintain a strain field without power. High temperature superconductors (HTS) are attractive options if the temperature of operation is higher than 10 degrees Kelvin (K) and below 77 K. However, HTS wires have constraints that limit the minimum radius of winding, and even if good wires can be produced, the technology for joining superconducting wires does not exist. In this paper, the design and capabilities of a rare earth zinc magnetostrictive actuator using bulk HTS is described. Bulk superconductors can be fabricated in the sizes required with excellent superconducting properties. Equivalent permanent magnets, made with this inexpensive material, are persistent, do not require a persistent switch as in HTS wires, and can be made very small. These devices are charged using a technique which is similar to the one used for charging permanent magnets, e.g., by driving them into saturation. A small normal conducting coil can be used for charging or discharging. Very fast charging and discharging of HTS tubes, as short as 100 microseconds, has been demonstrated. Because of the magnetic field capability of the superconductor material, a very small amount of superconducting magnet material is needed to actuate the rare earth zinc. In this paper, several designs o

    Research Ethics I: Responsible Conduct of Research (RCR)—Historical and Contemporary Issues Pertaining to Human and Animal Experimentation

    No full text
    corecore