22 research outputs found

    Data processing pipeline for Herschel HIFI

    Get PDF
    Context. The HIFI instrument on the Herschel Space Observatory performed over 9100 astronomical observations, almost 900 of which were calibration observations in the course of the nearly four-year Herschel mission. The data from each observation had to be converted from raw telemetry into calibrated products and were included in the Herschel Science Archive. Aims. The HIFI pipeline was designed to provide robust conversion from raw telemetry into calibrated data throughout all phases of the HIFI missions. Pre-launch laboratory testing was supported as were routine mission operations. Methods. A modular software design allowed components to be easily added, removed, amended and/or extended as the understanding of the HIFI data developed during and after mission operations. Results. The HIFI pipeline processed data from all HIFI observing modes within the Herschel automated processing environment as well as within an interactive environment. The same software can be used by the general astronomical community to reprocess any standard HIFI observation. The pipeline also recorded the consistency of processing results and provided automated quality reports. Many pipeline modules were in use since the HIFI pre-launch instrument level testing. Conclusions. Processing in steps facilitated data analysis to discover and address instrument artefacts and uncertainties. The availability of the same pipeline components from pre-launch throughout the mission made for well-understood, tested, and stable processing. A smooth transition from one phase to the next significantly enhanced processing reliability and robustness

    Data processing pipeline for Herschel HIFI

    Get PDF
    Context. The HIFI instrument on the Herschel Space Observatory performed over 9100 astronomical observations, almost 900 of which were calibration observations in the course of the nearly four-year Herschel mission. The data from each observation had to be converted from raw telemetry into calibrated products and were included in the Herschel Science Archive. Aims. The HIFI pipeline was designed to provide robust conversion from raw telemetry into calibrated data throughout all phases of the HIFI missions. Pre-launch laboratory testing was supported as were routine mission operations. Methods. A modular software design allowed components to be easily added, removed, amended and/or extended as the understanding of the HIFI data developed during and after mission operations. Results. The HIFI pipeline processed data from all HIFI observing modes within the Herschel automated processing environment as well as within an interactive environment. The same software can be used by the general astronomical community to reprocess any standard HIFI observation. The pipeline also recorded the consistency of processing results and provided automated quality reports. Many pipeline modules were in use since the HIFI pre-launch instrument level testing. Conclusions. Processing in steps facilitated data analysis to discover and address instrument artefacts and uncertainties. The availability of the same pipeline components from pre-launch throughout the mission made for well-understood, tested, and stable processing. A smooth transition from one phase to the next significantly enhanced processing reliability and robustness

    Influence of gestational age at initiation of antihypertensive therapy: secondary analysis of CHIPS trial data (control of hypertension in pregnancy study)

    Get PDF
    For hypertensive women in CHIPS (Control of Hypertension in Pregnancy Study), we assessed whether the maternal benefits of tight control could be achieved, while minimizing any potentially negative effect on fetal growth, by delaying initiation of antihypertensive therapy until later in pregnancy. For the 981 women with nonsevere, chronic or gestational hypertension randomized to less-tight (target diastolic blood pressure, 100 mm Hg), or tight (target, 85 mm Hg) control, we used mixed-effects logistic regression to examine whether the effect of less-tight (versus tight) control on major outcomes was dependent on gestational age at randomization, adjusting for baseline factors as in the primary analysis and including an interaction term between gestational age at randomization and treatment allocation. Gestational age was considered categorically (quartiles) and continuously (linear or quadratic form), and the optimal functional form selected to provide the best fit to the data based on the Akaike information criterion. Randomization before (but not after) 24 weeks to less-tight (versus tight) control was associated with fewer babies with birth weight 48 hours (Pinteraction=0.354). For the mother, less-tight (versus tight) control was associated with more severe hypertension at all gestational ages but particularly so before 28 weeks (Pinteraction=0.076). In women with nonsevere, chronic, or gestational hypertension, there seems to be no gestational age at which less-tight (versus tight) control is the preferred management strategy to optimize maternal or perinatal outcomes

    Influence of gestational age at initiation of antihypertensive therapy: Secondary analysis of CHIPS trial data (control of hypertension in pregnancy study).

    Get PDF
    For hypertensive women in CHIPS (Control of Hypertension in Pregnancy Study), we assessed whether the maternal benefits of tight control could be achieved, while minimizing any potentially negative effect on fetal growth, by delaying initiation of antihypertensive therapy until later in pregnancy. For the 981 women with nonsevere, chronic or gestational hypertension randomized to less-tight (target diastolic blood pressure, 100 mm Hg), or tight (target, 85 mm Hg) control, we used mixed-effects logistic regression to examine whether the effect of less-tight (versus tight) control on major outcomes was dependent on gestational age at randomization, adjusting for baseline factors as in the primary analysis and including an interaction term between gestational age at randomization and treatment allocation. Gestational age was considered categorically (quartiles) and continuously (linear or quadratic form), and the optimal functional form selected to provide the best fit to the data based on the Akaike information criterion. Randomization before (but not after) 24 weeks to less-tight (versus tight) control was associated with fewer babies with birth weight 48 hours (Pinteraction=0.354). For the mother, less-tight (versus tight) control was associated with more severe hypertension at all gestational ages but particularly so before 28 weeks (Pinteraction=0.076). In women with nonsevere, chronic, or gestational hypertension, there seems to be no gestational age at which less-tight (versus tight) control is the preferred management strategy to optimize maternal or perinatal outcomes

    X-Ray Fluorescence Microscopy Reveals Accumulation and Secretion of Discrete Intracellular Zinc Pools in the Lactating Mouse Mammary Gland

    Get PDF
    The mammary gland is responsible for the transfer of a tremendous amount of zinc ( approximately 1-3 mg zinc/day) from maternal circulation into milk during lactation to support the growth and development of the offspring. When this process is compromised, severe zinc deficiency compromises neuronal development and immune function and increases infant morbidity and/or mortality. It remains unclear as to how the lactating mammary gland dynamically integrates zinc import from maternal circulation with the enormous amount of zinc that is secreted into milk.Herein we utilized X-ray fluorescence microscopy (XFM) which allowed for the visualization and quantification of the process of zinc transfer through the mammary gland of the lactating mouse. Our data illustrate that a large amount of zinc first accumulates in the mammary gland during lactation. Interestingly, this zinc is not cytosolic, but accumulated in large, discrete sub-cellular compartments. These zinc pools were then redistributed to small intracellular vesicles destined for secretion in a prolactin-responsive manner. Confocal microscopy identified mitochondria and the Golgi apparatus as the sub-cellular compartments which accumulate zinc; however, zinc pools in the Golgi apparatus, but not mitochondria are redistributed to vesicles destined for secretion during lactation.Our data directly implicate the Golgi apparatus in providing a large, mobilizable zinc storage pool to assist in providing for the tremendous amount of zinc that is secreted into milk. Interestingly, our study also provides compelling evidence that mitochondrial zinc pools expand in the mammary gland during lactation which we speculate may play a role in regulating mammary gland function

    Women's views and postpartum follow-up in the CHIPS Trial (Control of Hypertension in Pregnancy Study).

    Get PDF
    OBJECTIVE: To compare women's views about blood pressure (BP) control in CHIPS (Control of Hypertension In Pregnancy Study) (NCT01192412). DESIGN: Quantitative and qualitative analysis of questionnaire responses. SETTING: International randomised trial (94 sites, 15 countries). POPULATION/SAMPLE: 911 (92.9%) women randomised to 'tight' (target diastolic blood pressure, 85mmHg) or 'less tight' (target diastolic blood pressure, 100mmHg) who completed questionnaires. METHODS: A questionnaire was administered at ∼6-12 weeks postpartum regarding post-discharge morbidity and views about trial participation. Questionnaires were administered by the site co-ordinator, and contact was made by phone, home or clinic visit; rarely, data was collected from medical records. Quantitative analyses were Chi-square or Fisher's exact test for categorical variables, mixed effects multinomial logistic regression to adjust for confounders, and p<0.001 for statistical significance. NVivo software was used for thematic analysis of women's views. MAIN OUTCOME MEASURES: Satisfaction, measured as willingness to have the same treatment in another pregnancy or recommend that treatment to a friend. RESULTS: Among the 533 women in 'tight' (N=265) vs. 'less tight' (N=268) control who provided comments for qualitative analysis, women in 'tight' (vs. 'less tight') control made fewer positive comments about the amount of medication taken (5 vs. 28 women, respectively) and intensity of BP monitoring (7 vs. 17, respectively). However, this did not translate into less willingness to either have the same treatment in another pregnancy (434, 95.8% vs. 423, 92.4%, respectively; p=0.14) or recommend that treatment to a friend (435, 96.0% and 428, 93.4%, respectively; p=0.17). Importantly, although satisfaction remained high among women with an adverse outcome, those in 'tight' control who suffered an adverse outcome (vs. those who did not) were not consistently less satisfied, whereas this was not the case among women in 'less tight' control among whom satisfaction was consistently lower for the CHIPS primary outcome (p<0.001), severe hypertension (p≤0.01), and pre-eclampsia (p<0.001). CONCLUSIONS: Women in 'tight' (vs. 'less tight') control were equally satisfied with their care, and more so in the face of adverse perinatal or maternal outcomes

    A gravity‐independent single‐phase electrode reservoir for capillary electrophoresis applications

    Full text link
    Capillary electrophoresis (CE) holds great promise as an in situ analytical technique for a variety of applications. However, typical instrumentation operates with open reservoirs (e.g., vials) to accommodate reagents and samples, which is problematic for automated instruments designed for space or underwater applications that may be operated in various orientations. Microgravity conditions add an additional challenge due to the unpredictable position of the headspace (air layer above the liquid) in any two‐phase reservoir. One potential solution for these applications is to use a headspace‐free, flow‐through reservoir design that is sealed and connected to the necessary reagents and samples. Here, we demonstrate a flow‐through high‐voltage (HV) reservoir for CE that is compatible with automated in situ exploration needs, and which can be electrically isolated from its source fluidics (in order to prevent unwanted leakage current). We also demonstrate how the overall system can be rationally designed based on the operational parameters for CE to prevent electrolysis products generated at the electrode from entering the capillary and interfering with the CE separation. A reservoir was demonstrated with a 19 mm long, 1.8 mm inner diameter channel connecting the separation capillary and the HV electrode. Tests of these reservoirs integrated into a CE system show reproducible CE system operation with a variety of background electrolytes at voltages up to 25 kV. Rotation of the reservoirs, and the system, showed that their performance was independent of the direction of the gravity vector

    Systematic yeast synthetic lethal and synthetic dosage lethal screens identify genes required for chromosome segregation

    No full text
    Accurate chromosome segregation requires the execution and coordination of many processes during mitosis, including DNA replication, sister chromatid cohesion, and attachment of chromosomes to spindle microtubules via the kinetochore complex. Additional pathways are likely involved because faithful chromosome segregation also requires proteins that are not physically associated with the chromosome. Using kinetochore mutants as a starting point, we have identified genes with roles in chromosome stability by performing genome-wide screens employing synthetic genetic array methodology. Two genetic approaches (a series of synthetic lethal and synthetic dosage lethal screens) isolated 211 nonessential deletion mutants that were unable to tolerate defects in kinetochore function. Although synthetic lethality and synthetic dosage lethality are thought to be based upon similar genetic principles, we found that the majority of interactions associated with these two screens were nonoverlapping. To functionally characterize genes isolated in our screens, a secondary screen was performed to assess defects in chromosome segregation. Genes identified in the secondary screen were enriched for genes with known roles in chromosome segregation. We also uncovered genes with diverse functions, such as RCS1, which encodes an iron transcription factor. RCS1 was one of a small group of genes identified in all three screens, and we used genetic and cell biological assays to confirm that it is required for chromosome stability. Our study shows that systematic genetic screens are a powerful means to discover roles for uncharacterized genes and genes with alternative functions in chromosome maintenance that may not be discovered by using proteomics approaches
    corecore