1,750 research outputs found

    Study of X-ray Radiation Damage in Silicon Sensors

    Full text link
    The European X-ray Free Electron Laser (XFEL) will deliver 30,000 fully coherent, high brilliance X-ray pulses per second each with a duration below 100 fs. This will allow the recording of diffraction patterns of single complex molecules and the study of ultra-fast processes. Silicon pixel sensors will be used to record the diffraction images. In 3 years of operation the sensors will be exposed to doses of up to 1 GGy of 12 keV X-rays. At this X-ray energy no bulk damage in silicon is expected. However fixed oxide charges in the insulating layer covering the silicon and interface traps at the Si-SiO2 interface will be introduced by the irradiation and build up over time. We have investigated the microscopic defects in test structures and the macroscopic electrical properties of segmented detectors as a function of the X-ray dose. From the test structures we determine the oxide charge density and the densities of interface traps as a function of dose. We find that both saturate (and even decrease) for doses between 10 and 100 MGy. For segmented sensors the defects introduced by the X-rays increase the full depletion voltage, the surface leakage current and the inter-pixel capacitance. We observe that an electron accumulation layer forms at the Si-SiO2 interface. Its width increases with dose and decreases with applied bias voltage. Using TCAD simulations with the dose dependent parameters obtained from the test structures, we are able to reproduce the observed results. This allows us to optimize the sensor design for the XFEL requirements

    La vie à l’ile Christmas

    Get PDF

    Performance of the EUDET-type beam telescopes

    Full text link
    Test beam measurements at the test beam facilities of DESY have been conducted to characterise the performance of the EUDET-type beam telescopes originally developed within the EUDET project. The beam telescopes are equipped with six sensor planes using MIMOSA26 monolithic active pixel devices. A programmable Trigger Logic Unit provides trigger logic and time stamp information on particle passage. Both data acquisition framework and offline reconstruction software packages are available. User devices are easily integrable into the data acquisition framework via predefined interfaces. The biased residual distribution is studied as a function of the beam energy, plane spacing and sensor threshold. Its standard deviation at the two centre pixel planes using all six planes for tracking in a 6\,GeV electron/positron-beam is measured to be (2.88\,\pm\,0.08)\,\upmu\meter.Iterative track fits using the formalism of General Broken Lines are performed to estimate the intrinsic resolution of the individual pixel planes. The mean intrinsic resolution over the six sensors used is found to be (3.24\,\pm\,0.09)\,\upmu\meter.With a 5\,GeV electron/positron beam, the track resolution halfway between the two inner pixel planes using an equidistant plane spacing of 20\,mm is estimated to (1.83\,\pm\,0.03)\,\upmu\meter assuming the measured intrinsic resolution. Towards lower beam energies the track resolution deteriorates due to increasing multiple scattering. Threshold studies show an optimal working point of the MIMOSA26 sensors at a sensor threshold of between five and six times their RMS noise. Measurements at different plane spacings are used to calibrate the amount of multiple scattering in the material traversed and allow for corrections to the predicted angular scattering for electron beams

    Simulation of the Response of the Solid State Neutron Detector for the European Spallation Source

    Full text link
    The characteristics of the Solid-state Neutron Detector, under development for neutron-scattering measurements at the European Spallation Source, have been simulated with a Geant4-based computer code. The code models the interations of thermal neutrons and ionising radiation in the 6Li-doped scintillating glass of the detector, the production of scintillation light and the transport of optical, scintillation photons through the the scintillator, en route to the photo-cathode of the attached multi-anode photomultiplier. Factors which affect the optical-photon transport, such as surface finish, pixelation of the glass sheet, provision of a front reflector and optical coupling media are compared. Predictions of the detector response are compared with measurements made with neutron and gamma-ray sources, a collimated alpha source and finely collimated beams of 2.5 MeV protons and deuterons.Comment: Preprint 22 pages, 12 figures, published in NIM

    UK meteotsunamis: a revision and update on events and their frequency

    Get PDF
    A tsunami is a series of waves caused by the displacement of water. The displacement may result from ‘bottom‐up’ seabed movement, such as caused by earthquakes, landslides and volcanic eruptions or ‘top‐down’ movement, from pressure perturbations in the atmosphere. These ‘top‐down’ events are termed meteotsunamis. Meteotsunamis frequently occur in the Mediterranean, the Baltic Sea, the east coast and Great Lakes of North America, and Japan, so they are not exclusive to the United Kingdom. The most recent meteotsunami near the UK coast was in May 2017, when waves around 2m in elevation, generated by a storm passing over the UK, struck the coast of the Netherlands. Historical documents covering the past 150 years describe many meteotsunamis from United Kingdom (UK) coastal waters (Haslett et al ., 2009; Haslett and Bryant, 2009; Tappin et al ., 2013; Vilibić et al ., 2015; O'Brien et al ., 2018). Some of these events have resulted in fatalities, involving beach users who were struck by unexpected sea waves. Meteotsunamis commonly strike the coasts of the UK, damaging harbours, boats and very rarely, causing fatalities. In the UK, they were usually detected by analysis after the event, unless witnessed first‐hand. This post‐event analysis is particularly necessary in the UK because the data provided by the tide gauge system, operated by the Environment Agency, only records at 15‐min intervals, not in real time as in the rest of Europe. The periods of meteotsunamis are in the range of minutes to tens of minutes (Pattiaratchi and Wijeratne, 2015). A frequency of tens of minutes is similar to a typical frequency expected from a meteotsunami that would have an amplified response from harbour or bay resonance (Tappin et al ., 2013). Therefore, those occurring in UK waters are not often recorded with the present tide gauge settings and as a consequence, cannot be analysed effectively

    Response of a Li-glass/multi-anode photomultiplier detector to collimated thermal-neutron beams

    Get PDF
    The response of a position-sensitive Li-glass scintillator detector being developed for thermal-neutron detection with 6 mm position resolution has been investigated using collimated beams of thermal neutrons. The detector was moved perpendicularly through the neutron beams in 0.5 to 1.0 mm horizontal and vertical steps. Scintillation was detected in an 8 X 8 pixel multi-anode photomultiplier tube on an event-by-event basis. In general, several pixels registered large signals at each neutron-beam location. The number of pixels registering signal above a set threshold was investigated, with the maximization of the single-hit efficiency over the largest possible area of the detector as the primary goal. At a threshold of ~50% of the mean of the full-deposition peak, ~80% of the events were registered in a single pixel, resulting in an effective position resolution of ~5 mm in X and Y. Lower thresholds generally resulted in events demonstrating higher pixel multiplicities, but these events could also be localized with ~5 mm position resolution.Comment: 23 pages, 8 figure

    High-E_T dijet photoproduction at HERA

    Get PDF
    The cross section for high-E_T dijet production in photoproduction has been measured with the ZEUS detector at HERA using an integrated luminosity of 81.8 pb-1. The events were required to have a virtuality of the incoming photon, Q^2, of less than 1 GeV^2 and a photon-proton centre-of-mass energy in the range 142 < W < 293 GeV. Events were selected if at least two jets satisfied the transverse-energy requirements of E_T(jet1) > 20 GeV and E_T(jet2) > 15 GeV and pseudorapidity requirements of -1 < eta(jet1,2) < 3, with at least one of the jets satisfying -1 < eta(jet) < 2.5. The measurements show sensitivity to the parton distributions in the photon and proton and effects beyond next-to-leading order in QCD. Hence these data can be used to constrain further the parton densities in the proton and photon.Comment: 36 pages, 13 figures, 20 tables, including minor revisions from referees. Accepted by Phys. Rev.
    • 

    corecore