8,130 research outputs found

    The Valuation of Unprotected Works: A Case Study of Public Domain Images on Wikipedia

    Get PDF

    PHP35 Is There a Difference in Prescription Medication Utilization Between Aged Adults with and Without Disability in the United States?

    Get PDF

    Spurious phase in a model for traffic on a bridge

    Full text link
    We present high-precision Monte Carlo data for the phase diagram of a two-species driven diffusive system, reminiscent of traffic across a narrow bridge. Earlier studies reported two phases with broken symmetry; the existence of one of these has been the subject of some debate. We show that the disputed phase disappears for sufficiently large systems and/or sufficiently low bulk mobility.Comment: 8 pages, 3 figures, JPA styl

    Precise calibration of LIGO test mass actuators using photon radiation pressure

    Full text link
    Precise calibration of kilometer-scale interferometric gravitational wave detectors is crucial for source localization and waveform reconstruction. A technique that uses the radiation pressure of a power-modulated auxiliary laser to induce calibrated displacements of one of the ~10 kg arm cavity mirrors, a so-called photon calibrator, has been demonstrated previously and has recently been implemented on the LIGO detectors. In this article, we discuss the inherent precision and accuracy of the LIGO photon calibrators and several improvements that have been developed to reduce the estimated voice coil actuator calibration uncertainties to less than 2 percent (1-sigma). These improvements include accounting for rotation-induced apparent length variations caused by interferometer and photon calibrator beam centering offsets, absolute laser power measurement using temperature-controlled InGaAs photodetectors mounted on integrating spheres and calibrated by NIST, minimizing errors induced by localized elastic deformation of the mirror surface by using a two-beam configuration with the photon calibrator beams symmetrically displaced about the center of the optic, and simultaneously actuating the test mass with voice coil actuators and the photon calibrator to minimize fluctuations caused by the changing interferometer response. The photon calibrator is able to operate in the most sensitive interferometer configuration, and is expected to become a primary calibration method for future gravitational wave searches.Comment: 13 pages, 6 figures, accepted by Classical and Quantum Gravit

    Precise calibration of LIGO test mass actuators using photon radiation pressure

    Full text link
    Precise calibration of kilometer-scale interferometric gravitational wave detectors is crucial for source localization and waveform reconstruction. A technique that uses the radiation pressure of a power-modulated auxiliary laser to induce calibrated displacements of one of the ~10 kg arm cavity mirrors, a so-called photon calibrator, has been demonstrated previously and has recently been implemented on the LIGO detectors. In this article, we discuss the inherent precision and accuracy of the LIGO photon calibrators and several improvements that have been developed to reduce the estimated voice coil actuator calibration uncertainties to less than 2 percent (1-sigma). These improvements include accounting for rotation-induced apparent length variations caused by interferometer and photon calibrator beam centering offsets, absolute laser power measurement using temperature-controlled InGaAs photodetectors mounted on integrating spheres and calibrated by NIST, minimizing errors induced by localized elastic deformation of the mirror surface by using a two-beam configuration with the photon calibrator beams symmetrically displaced about the center of the optic, and simultaneously actuating the test mass with voice coil actuators and the photon calibrator to minimize fluctuations caused by the changing interferometer response. The photon calibrator is able to operate in the most sensitive interferometer configuration, and is expected to become a primary calibration method for future gravitational wave searches.Comment: 13 pages, 6 figures, accepted by Classical and Quantum Gravit

    Charge Exchange Spectra of Hydrogenic and He-like Iron

    Full text link
    We present H-like Fe XXVI and He-like Fe XXV charge-exchange spectra resulting from collisions of highly charged iron with N2 gas at an energy of 10 eV/amu in an electron beam ion trap. Although individual high-n emission lines are not resolved in our measurements, we observe that the most likely level for Fe25+ --> Fe24+ electron capture is n~9, in line with expectations, while the most likely value for Fe26+ --> Fe25+ charge exchange is significantly higher. In the Fe XXV spectrum, the K-alpha emission feature dominates, whether produced via charge exchange or collisional excitation. The K-alpha centroid is lower in energy for the former case than the latter (6666 versus 6685 eV, respectively), as expected because of the strong enhancement of emission from the forbidden and intercombination lines, relative to the resonance line, in charge-exchange spectra. In contrast, the Fe XXVI high-n Lyman lines have a summed intensity greater than that of Ly-alpha, and are substantially stronger than predicted from theoretical calculations of charge exchange with atomic H. We conclude that the angular momentum distribution resulting from electron capture using a multi-electron target gas is significantly different from that obtained with H, resulting in the observed high-n enhancement. A discussion is presented of the relevance of our results to studies of diffuse Fe emission in the Galactic Center and Galactic Ridge, particularly with ASTRO-E2/Suzaku.Comment: 16 pages, 4 figures (3 color), accepted by Ap

    Higher-order binding corrections to the Lamb shift of 2P states

    Get PDF
    We present an improved calculation of higher-order corrections to the one-loop self energy of 2P states in hydrogen-like systems with small nuclear charge Z. The method is based on a division of the integration with respect to the photon energy into a high- and a low-energy part. The high-energy part is calculated by an expansion of the electron propagator in powers of the Coulomb field. The low-energy part is simplified by the application of a Foldy-Wouthuysen transformation. This transformation leads to a clear separation of the leading contribution from the relativistic corrections and removes higher order terms. The method is applied to the 2P_{1/2} and 2P_{3/2} states in atomic hydrogen. The results lead to new theoretical values for the Lamb shifts and the fine structure splitting.Comment: 18 pages, LaTeX. In comparison to the journal version, it contains an added note (2000) which reflects the current status of Lamb shift calculation

    Capturing an Evolving Nebular Environment: A Petrographic and Geochemical Study of a Type A, B & C CAI

    Get PDF
    Calcium, Aluminum-rich Inclusions (CAIs) were the first formed solids in our Solar System, with mineral assemblages reflecting the first phases predicted to condense out of a hot nebular gas of Solar composition. Geochemical, textural and crystallographic information in CAIs can be used to constrain the temperature, pressure, and composition (e.g., oxygen fugacity) of the gaseous reservoir(s) from which they formed, as well as any secondary (nebular and parent body) processes they underwent. Coordinated geochemical and textural analyses provide information on nebular conditions (i.e., astrophysical environments and dynamics of nebular gas reservoirs) in which these CAIs formed. In order to better understand the evolution of nebular reservoirs at the time of CAI formation, we analyzed a Type A, B and C CAI using Electron Probe Micro-Analyzer (EPMA) and Electron BackScatter Diffraction (EBSD) at NASA Johnson Space Center (JSC)

    Radar systems for the water resources mission. Volume 4: Appendices E-I

    Get PDF
    The use of a scanning antenna beam for a synthetic aperture system was examined. When the resolution required was modest, the radar did not use all the time the beam was passing a given point on the ground to build a synthetic aperture, so time was available to scan the beam to other positions and build several images at different ranges. The scanning synthetic-aperture radar (SCANSAR) could achieve swathwidths of well over 100 km with modest antenna size. Design considerations for a SCANSAR for hydrologic parameter observation are presented. Because of the high sensitivity to soil moisture at angles of incidence near vertical, a 7 to 22 deg swath was considered for that application. For snow and ice monitoring, a 22 to 37 deg scan was used. Frequencies from X-band to L-band were used in the design studies, but the proposed system operated in C-band at 4.75 GHz. It achieved an azimuth resolution of about 50 meters at all angles, with a range resolution varying from 150 meters at 7 deg to 31 meters at 37 deg. The antenna required an aperture of 3 x 4.16 meters, and the average transmitter power was under 2 watts

    Polymerase chain reactions with alphoid-repeat primers in combination with Alu or LINEs primers, generate chromosome-specific DNA fragments

    Full text link
    Y alphoid primers in combination with Alu and LINEs primers generated new DNA fragments in polymerase chain reactions (PCR) on DNA from a Y-only somatic cell hybrid but not from X-only, 3-only, or 21-only hybrids. X alphoid primers used in a similar manner generated new DNA fragments from the X-only hybrid, and 1 of the primers (X 2 ) also generated new DNA fragments on 3-only and 21-only hybrids when used in conjunction with Alu or LINEs primers. In all but one case, consensus alphoid primers generated new chromosome-specific fragments in PCR reactions with the Alu or LINEs primers. A search for cryptic Alu- or alphoid-alone PCR products as the source for one Alu -alphoid band (chosen at random) was negative. Partial sequencing of products demonstrated that alphoid and Alu sequences were indeed contiguous in some newly synthesized DNA fragments. While Alu or LINEs primers generate smears of DNA fragments on total human DNA, the alphoid-nonalphoid repeat combinations generated electrophoretically distinguishable bands of DNA when the template was total DNA. While these were distinguishable with different chromosome-specific alphoid primers, the DNA fragments were not of the same sizes as those generated with the chromosome-only hybrids.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/66359/1/j.1469-1809.1991.tb00414.x.pd
    • …
    corecore