176 research outputs found

    Loving-kindness meditation: a tool to improve healthcare provider compassion, resilience, and patient care

    Get PDF
    Background: Stress is a critical problem facing many healthcare institutions. The consequences of stress include increased provider burnout and decreased quality of care for patients. Ironically, a key factor that may help buffer the impact of stress on provider well-being and patient health outcomes—compassion—is low in healthcare settings and declines under stress. This gives rise to an urgent question: what practical steps can be taken to increase compassion, thereby benefitting both provider well-being and patient care? Methods: We investigated the relative effectiveness of a short, 10-minute session of loving-kindness meditation (LKM) to increase compassion and positive affect. We compared LKM to a non-compassion positive affect induction (PAI) and a neutral visualization (NEU) condition. Self- and other-focused affect, self-reported measures of social connection, and semi-implicit measures of self-focus were measured pre- and post- meditation using repeated measures ANOVAs and via paired sample t-tests for follow-up comparisons. Results: Findings show that LKM improves well-being and feelings of connection over and above other positive-affect inductions, at both explicit and implicit levels, while decreasing self-focus in under 10 minutes and in novice meditators. Conclusions: These findings suggest that LKM may be a viable, practical, and time-effective solution for preventing burnout and promoting resilience in healthcare providers and for improving quality of care in patients

    Large-area submillimeter resolution CdZnTe strip detector for astronomy

    Get PDF
    We report the first performance measurements of a sub-millimeter CdZnTe strip detector developed as a prototype for space-borne astronomical instruments. Strip detector arrays can be used to provide two-dimensional position resolution with fewer electronic channels than pixellated arrays. Arrays of this type and other candidate technologies are under investigation for the position-sensitive backplane detector for a coded-aperture telescope operating in the range of 30 - 300 keV. The prototype is a 1.4 mm thick, 64 multiplied by 64 stripe CdZnTe array of 0.375 mm pitch in both dimensions, approximately one square inch of sensitive area. Pulse height spectra in both single and orthogonal stripe coincidence mode were recorded at several energies. The results are compared to slab- and pixel-geometry detector spectra. The room-temperature energy resolution is less than 10 keV (FWHM) for 122 keV photons with a peak-to-valley ratio greater than 5:1. The response to photons with energies up to 662 keV appears to be considerably improved relative to that of previously reported slab and pixel detectors. We also show that strip detectors can yield spatial and energy resolutions similar to those of pixellated arrays with the same dimensions. Electrostatic effects on the pulse heights, read-out circuit complexity, and issues related to design of space borne instruments are also discussed

    Bounding the dimensions of rational cohomology groups

    Full text link
    Let kk be an algebraically closed field of characteristic p>0p > 0, and let GG be a simple simply-connected algebraic group over kk that is defined and split over the prime field Fp\mathbb{F}_p. In this paper we investigate situations where the dimension of a rational cohomology group for GG can be bounded by a constant times the dimension of the coefficient module. We then demonstrate how our results can be applied to obtain effective bounds on the first cohomology of the symmetric group. We also show how, for finite Chevalley groups, our methods permit significant improvements over previous estimates for the dimensions of second cohomology groups.Comment: 13 page

    Development of an orthogonal-stripe CdZnTe gamma radiation imaging spectrometer

    Get PDF
    We report performance measurements of a sub-millimeter resolution CdZnTe strip detector developed as a prototype for astronomical instruments operating with good efficiency in the 30-300 keV photon energy range. The prototype is a 1.4 mm thick, 64Ă—64 contact stripe CdZnTe array of 0.375 mm pitch in both dimensions. Pulse height spectra were recorded in orthogonal-stripe coincidence mode which demonstrate room-temperature energy resolution \u3c10 keV (FWHM) for 122 keV photons with a peak-to-valley ratio \u3e5:1. Good response is also demonstrated at higher energies using a coplanar grid readout configuration. Spatial resolution capabilities finer than the stripe pitch are demonstrated. We present the image of a 133Ba source viewed through a collimator slit produced by a 4Ă—4 stripe detector segment. Charge signals from electron and hole collecting contacts are also discussed

    CdZnTe strip detectors as sub-millimeter resolution imaging gamma radiation spectrometers

    Get PDF
    We report Îł-ray detection performance measurements and computer simulations of a sub-millimeter pitch CdZnTe strip detector. The detector is a prototype for Îł-ray measurements in the range of 20-600 keV. The prototype is a 1.5 mm thick, 64Ă—64 orthogonal stripe CdZnTe detector of 0.375 mm pitch in both dimensions, with approximately one square inch of sensitive area. Using discrete laboratory electronics to process signals from an 8Ă—8 stripe region of the prototype we measured good spectroscopic uniformity and sub-pitch (~0.2 mm) spatial resolution in both x and y dimensions. We present below measurements of the spatial uniformity, relative timing and pulse height of the anode and cathode signals. We simulated the photon interactions and signal generation in the strip detector and the test electronics and we compare these results with the data. The data indicate that cathode signal-as well as the anode signal-arises more strongly from the conduction electrons rather than the holes

    Performance of CdZnTe strip detectors as sub-millimeter resolution imaging gamma radiation spectrometers

    Get PDF
    We report & gamma;-ray detection performance measurements and computer simulations of a sub-millimeter pitch CdZnTe strip detector. The detector is a prototype for & gamma;-ray astronomy measurements in the range of 20-200 keV. The prototype is a 1.5 mm thick, 64Ă—64 orthogonal stripeCdZnTe detector of 0.375 mm pitch in both dimensions, with approximately one square inch of sensitive area. Using discrete laboratory electronics to process signals from an 8Ă—8 stripe region of the prototype we measured good spectroscopic uniformity and sub-pitch (~0.2 mm) spatial resolution in both x and y dimensions. We present below measurements of the spatial uniformity, relative timing and pulse height of the anode and cathode signals, and the photon detection efficiency. We also present a technique for determining the location of the event in the third dimension (depth). We simulated the photon interactions and signal generation in the strip detector and the test electronics and we compare these results with the data. The data indicate that the cathode signal-as well as the anode signal-arises more strongly from the conduction electrons rather than the holes

    Olfaction: anatomy, physiology and behavior

    Get PDF
    The anatomy, physiology and function of the olfactory system are reviewed, as are the normal effects of olfactory stimulation. It is speculated that olfaction may have important but unobtrusive effects on human behavior

    Determination of freedom-from-rabies for small Indian mongoose populations in the United States Virgin Islands, 2019–2020

    Get PDF
    Mongooses, a nonnative species, are a known reservoir of rabies virus in the Caribbean region. A cross-sectional study of mongooses at 41 field sites on the US Virgin Islands of St. Croix, St. John, and St. Thomas captured 312 mongooses (32% capture rate). We determined the absence of rabies virus by antigen testing and rabies virus exposure by antibody testing in mongoose populations on all three islands. USVI is the first Caribbean state to determine freedom-from-rabies for its mongoose populations with a scientifically-led robust cross-sectional study. Ongoing surveillance activities will determine if other domestic and wildlife populations in USVI are rabies-free
    • …
    corecore