3,324 research outputs found

    Long-term effects of chronic light pollution on seasonal functions of European blackbirds (turdus merula)

    Get PDF
    Light pollution is known to affect important biological functions of wild animals, including daily and annual cycles. However, knowledge about long-term effects of chronic exposure to artificial light at night is still very limited. Here we present data on reproductive physiology, molt and locomotor activity during two-year cycles of European blackbirds (Turdus merula) exposed to either dark nights or 0.3 lux at night. As expected, control birds kept under dark nights exhibited two regular testicular and testosterone cycles during the two-year experiment. Control urban birds developed testes faster than their control rural conspecifics. Conversely, while in the first year blackbirds exposed to light at night showed a normal but earlier gonadal cycle compared to control birds, during the second year the reproductive system did not develop at all: both testicular size and testosterone concentration were at baseline levels in all birds. In addition, molt sequence in light-treated birds was more irregular than in control birds in both years. Analysis of locomotor activity showed that birds were still synchronized to the underlying light-dark cycle. We suggest that the lack of reproductive activity and irregular molt progression were possibly the results of i) birds being stuck in a photorefractory state and/or ii) chronic stress. Our data show that chronic low intensities of light at night can dramatically affect the reproductive system. Future studies are needed in order to investigate if and how urban animals avoid such negative impact and to elucidate the physiological mechanisms behind these profound long-term effects of artificial light at night. Finally we call for collaboration between scientists and policy makers to limit the impact of light pollution on animals and ecosystems

    Endoscopic Cubital Tunnel Recurrence Rates

    Get PDF
    Cubital tunnel syndrome is the second most common nerve entrapment in the upper extremity. There are no current publications concerning the recurrence rates after endoscopic cubital tunnel release. The purpose of this study is to evaluate the recurrence rate of endoscopic cubital tunnel release compared to published reports of recurrence following open cubital tunnel procedures. We reviewed 134 consecutive cases of endoscopic cubital tunnel release in 117 patients. There were 104 cases in 94 patients with greater than 3 months follow-up. The mean follow-up time was 736 days. They were grouped using Dellon’s classification. Two literature control groups were used from published reports of recurrence rate following open cubital tunnel release. A recurrence was identified if the patient was symptom-free following surgery but had symptoms reappear 3 months or more after surgery as defined in the literature. Of the 104 cases, 92.31% had more than a 4-month follow-up. One case (0.96%) met the criteria for recurrence at 4 months postprocedure. Data were then compared to the literature control groups used from published reports of recurrence rates following open cubital tunnel release. Pooled, the combined controls had 22 of 180 cases (12.22%) with recurrences. The percentage of procedure recurrence varied significantly with p value equal to 0.0004. It is recognized that there is a lack of common classification and comparative analysis of these studies, but they do classify preoperative grading and recurrence similarly. We are 95% confident that our true recurrence rate is between 0.02% and 5.24% and that endoscopic cubital tunnel release has a recurrence rate, which is not higher than open cubital tunnel release literature controls

    A cross-sectional study of Victorian mobile intensive care ambulance paramedics knowledge of the Valsalva manoeuvre

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The Valsalva Manoeuvre (VM) is a primary measure for terminating haemodynamically stable supraventricular tachycardia (SVT) in the emergency care setting. The clinical use and termination success of the VM in the prehospital setting has not been investigated to date. The objective of this study was to determine Melbourne Mobile Intensive Care Ambulance (MICA) Paramedic knowledge of the VM, and to compare this understanding with an evidence-based model of VM performance.</p> <p>Methods</p> <p>A cross-sectional study in the form of a face-to-face interview was used to determine Melbourne MICA Paramedic understanding of VM instruction between January and February, 2008. The results were then compared with an evidence-based model of VM performance to ascertain compliance with the three criteria of position, pressure and duration. Ethics approval was granted.</p> <p>Results</p> <p>There were 28 participants (60.9%) who elected a form of supine posturing, some 23 participants (50%) selected the syringe method of pressure generation, with 16 participants (34.8%) selecting the "as long as you can" option for duration. On comparison, one out of 46 MICA Paramedics correctly identified the three evidence-based criteria.</p> <p>Conclusions</p> <p>The formal education of Melbourne's MICA Paramedics would benefit from the introduction of an evidence based model of VM performance, which would impact positively on patient care and may improve reversion success in the prehospital setting. The results of this study also demonstrate that an opportunity exists to promote the evidence-based VM criteria across the primary emergency care field.</p

    Analysing detection gaps in acoustic telemetry data to infer differential movement patterns in fish

    Get PDF
    A wide array of technologies are available for gaining insight into the movement of wild aquatic animals. Although acoustic telemetry can lack the fine‐scale spatial resolution of some satellite tracking technologies, the substantially longer battery life can yield important long‐term data on individual behavior and movement for low per‐unit cost. Typically, however, receiver arrays are designed to maximize spatial coverage at the cost of positional accuracy leading to potentially longer detection gaps as individuals move out of range between monitored locations. This is particularly true when these technologies are deployed to monitor species in hard‐to‐access locations. Here, we develop a novel approach to analyzing acoustic telemetry data, using the timing and duration of gaps between animal detections to infer different behaviors. Using the durations between detections at the same and different receiver locations (i.e., detection gaps), we classify behaviors into “restricted” or potential wider “out‐of‐range” movements synonymous with longer distance dispersal. We apply this method to investigate spatial and temporal segregation of inferred movement patterns in two sympatric species of reef shark within a large, remote, marine protected area (MPA). Response variables were generated using network analysis, and drivers of these movements were identified using generalized linear mixed models and multimodel inference. Species, diel period, and season were significant predictors of “out‐of‐range” movements. Silvertip sharks were overall more likely to undertake “out‐of‐range” movements, compared with gray reef sharks, indicating spatial segregation, and corroborating previous stable isotope work between these two species. High individual variability in “out‐of‐range” movements in both species was also identified. We present a novel gap analysis of telemetry data to help infer differential movement and space use patterns where acoustic coverage is imperfect and other tracking methods are impractical at scale. In remote locations, inference may be the best available tool and this approach shows that acoustic telemetry gap analysis can be used for comparative studies in fish ecology, or combined with other research techniques to better understand functional mechanisms driving behavior

    Urinary Proteomics to Support Diagnosis of Stroke

    Get PDF
    Accurate diagnosis in suspected ischaemic stroke can be difficult. We explored the urinary proteome in patients with stroke (n = 69), compared to controls (n = 33), and developed a biomarker model for the diagnosis of stroke. We performed capillary electrophoresis online coupled to micro-time-of-flight mass spectrometry. Potentially disease-specific peptides were identified and a classifier based on these was generated using support vector machine-based software. Candidate biomarkers were sequenced by liquid chromatography-tandem mass spectrometry. We developed two biomarker-based classifiers, employing 14 biomarkers (nominal p-value <0.004) or 35 biomarkers (nominal p-value <0.01). When tested on a blinded test set of 47 independent samples, the classification factor was significantly different between groups; for the 35 biomarker model, median value of the classifier was 0.49 (−0.30 to 1.25) in cases compared to −1.04 (IQR −1.86 to −0.09) in controls, p<0.001. The 35 biomarker classifier gave sensitivity of 56%, specificity was 93% and the AUC on ROC analysis was 0.86. This study supports the potential for urinary proteomic biomarker models to assist with the diagnosis of acute stroke in those with mild symptoms. We now plan to refine further and explore the clinical utility of such a test in large prospective clinical trials

    LHC Discovery Potential for Non-Standard Higgs Bosons in the 3b Channel

    Get PDF
    In a variety of well motivated models, such as two Higgs Doublet Models (2HDMs) and the Minimal Supersymmetric Standard Model (MSSM), there are neutral Higgs bosons that have significantly enhanced couplings to b-quarks and tau leptons in comparison to those of the SM Higgs. These so called non-standard Higgs bosons could be copiously produced at the LHC in association with b quarks, and subsequently decay into b-quark pairs. However, this production channel suffers from large irreducible QCD backgrounds. We propose a new search strategy for non-standard neutral Higgs bosons at the 7 TeV LHC in the 3b's final state topology. We perform a simulation of the signal and backgrounds, using state of the art tools and methods for different sets of selection cuts, and conclude that neutral Higgs bosons with couplings to b-quarks of about 0.3 or larger, and masses up to 400 GeV, could be seen with a luminosity of 30 fb^{-1}. In the case of the MSSM we also discuss the complementarity between the 3b channel and the inclusive tau pair channel in exploring the supersymmetric parameter space.Comment: 14 pages, 3 figures, 4 tables, references added, published versio

    Hadronic production of bottom-squark pairs with electroweak contributions

    Get PDF
    We present the complete computation of the tree-level and the next-to-leading order electroweak contributions to bottom-squark pair production at the LHC. The computation is performed within the minimal supersymmetric extension of the Standard Model. We discuss the numerical impact of these contributions in several supersymmetric scenarios.Comment: 33 pages, v2: preprint numbers correcte
    corecore