461 research outputs found

    Fourier analysis of wave turbulence in a thin elastic plate

    Full text link
    The spatio-temporal dynamics of the deformation of a vibrated plate is measured by a high speed Fourier transform profilometry technique. The space-time Fourier spectrum is analyzed. It displays a behavior consistent with the premises of the Weak Turbulence theory. A isotropic continuous spectrum of waves is excited with a non linear dispersion relation slightly shifted from the linear dispersion relation. The spectral width of the dispersion relation is also measured. The non linearity of this system is weak as expected from the theory. Finite size effects are discussed. Despite a qualitative agreement with the theory, a quantitative mismatch is observed which origin may be due to the dissipation that ultimately absorbs the energy flux of the Kolmogorov-Zakharov casade.Comment: accepted for publication in European Physical Journal B see http://www.epj.or

    Percutaneous ablation techniques for renal cell carcinoma: current status and future trends

    Get PDF
    Percutaneous ablation is an increasingly applied technique for the treatment of localized renal tumors, especially for elderly or co-morbid patients, where co-morbidities increase the risk of traditional nephrectomy. Ablative techniques are technically suited for the treatment of tumors generally not exceeding 4 cm, which has been set as general consensus cutoff and is described as the upper threshold of T1a kidney tumors. This threshold cutoff is being challenged, but with still limited evidence. Percutaneous ablation techniques for the treatment of renal cell carcinoma (RCC) include radiofrequency ablation, cryoablation, laser or microwave ablation; the main advantage of all these techniques over surgery is less invasiveness, lower complication rates and better patient tolerability. Currently, international guidelines recommend percutaneous ablation either as intervention for frail patients or as a first line tool, provided that the tumor can be radically ablated. The purpose of this article is to describe the basic concepts of percutaneous ablation in the treatment of RCC. Controversies concerning techniques and products and the need for patient-centered tailored approaches during selection among the different techniques available will be discussed

    Kolmogorov turbulence, Anderson localization and KAM integrability

    Full text link
    The conditions for emergence of Kolmogorov turbulence, and related weak wave turbulence, in finite size systems are analyzed by analytical methods and numerical simulations of simple models. The analogy between Kolmogorov energy flow from large to small spacial scales and conductivity in disordered solid state systems is proposed. It is argued that the Anderson localization can stop such an energy flow. The effects of nonlinear wave interactions on such a localization are analyzed. The results obtained for finite size system models show the existence of an effective chaos border between the Kolmogorov-Arnold-Moser (KAM) integrability at weak nonlinearity, when energy does not flow to small scales, and developed chaos regime emerging above this border with the Kolmogorov turbulent energy flow from large to small scales.Comment: 8 pages, 6 figs, EPJB style

    Are Urologists Ready for Interpretation of Multiparametric MRI Findings? A Prospective Multicentric Evaluation

    Get PDF
    Aim: To assess urologists’ proficiency in the interpretation of multiparametric magnetic resonance imaging (mpMRI). Materials and Methods: Twelve mpMRIs were shown to 73 urologists from seven Italian institutions. Responders were asked to identify the site of the suspicious nodule (SN) but not to assign a PIRADS score. We set an a priori cut-off of 75% correct identification of SN as a threshold for proficiency in mpMRI reading. Data were analyzed according to urologists’ hierarchy (UH; resident vs. consultant) and previous experience in fusion prostate biopsies (E-fPB, defined as <125 vs. ≥125). Additionally, we tested for differences between non-proficient vs. proficient mpMRI readers. Multivariable logistic regression analyses (MVLRA) tested potential predictors of proficiency in mpMRI reading. Results: The median (IQR) number of correct identifications was 8 (6–8). Anterior nodules (number 3, 4 and 6) represented the most likely prone to misinterpretation. Overall, 34 (47%) participants achieved the 75% cut-off. When comparing consultants vs. residents, we found no differences in terms of E-fPB (p = 0.9) or in correct identification rates (p = 0.6). We recorded higher identification rates in urologists with E-fBP vs. their no E-fBP counterparts (75% vs. 67%, p = 0.004). At MVLRA, only E- fPB reached the status of independent predictor of proficiency in mpMRI reading (OR: 3.4, 95% CI 1.2–9.9, p = 0.02) after adjusting for UH and type of institution. Conclusions: Despite urologists becoming more familiar with interpretation of mpMRI, their results are still far from proficient. E-fPB enhances the proficiency in mpMRI interpretation

    A comparison of Power Doppler with conventional sonographic imaging for the evaluation of renal artery stenosis

    Get PDF
    BACKGROUND: Power Doppler (PD) has improved diagnostic capabilities of vascular sonography, mainly because it is independent from the angle of insonation. We evaluated this technique in a prospective comparison with conventional imaging, consisting in Duplex and Color Doppler, for the evaluation of Renal Artery (RA) stenosis. METHODS: Sensitivity, specificity and predictive values of PD and conventional imaging were assessed in a blinded fashion on eighteen patients, 9 with angiographic evidence of unilateral RA stenosis (hypertensive patients) and 9 with angiographically normal arteries (control group). PD images were interpreted with an angiography-like criteria. RESULTS: In the control group both techniques allowed correct visualization of 16 out of the 18 normal arteries (93% specificity). Only in five hypertensive patients RA stenosis was correctly identified with conventional technique (56% sensitivity and 86% negative predictive value); PD was successful in all hypertensive patients (100% sensitivity and negative predictive value), since the operators could obtain in each case of RA stenosis a sharp color signal of the whole vessel with a clear "minus" at the point of narrowing of the lumen. All results were statistically significant (p < 0.01). CONCLUSIONS: This study demonstrates that PD is superior to conventional imaging, in terms of sensitivity and specificity, for the diagnosis of RA stenosis, because it allows a clear visualization of the whole stenotic vascular lumen. Especially if it is used in concert with the other sonographic techniques, PD can enable a more accurate imaging of renovascular disease with results that seem comparable to selective angiography

    In silico assessment of biomedical products: the conundrum of rare but not so rare events in two case studies

    Get PDF
    In silico clinical trials, defined as “The use of individualized computer simulation in the development or regulatory evaluation of a medicinal product, medical device, or medical intervention,” have been proposed as a possible strategy to reduce the regulatory costs of innovation and the time to market for biomedical products. We review some of the the literature on this topic, focusing in particular on those applications where the current practice is recognized as inadequate, as for example, the detection of unexpected severe adverse events too rare to be detected in a clinical trial, but still likely enough to be of concern. We then describe with more details two case studies, two successful applications of in silico clinical trial approaches, one relative to the University of Virginia/Padova simulator that the Food and Drug Administration has accepted as possible replacement for animal testing in the preclinical assessment of artificial pancreas technologies, and the second, an investigation of the probability of cardiac lead fracture, where a Bayesian network was used to combine in vivo and in silico observations, suggesting a whole new strategy of in silico-augmented clinical trials, to be used to increase the numerosity where recruitment is impossible, or to explore patients’ phenotypes that are unlikely to appear in the trial cohort, but are still frequent enough to be of concern

    Diagnostic role of new Doppler index in assessment of renal artery stenosis

    Get PDF
    BACKGROUND: Renal artery stenosis (RAS) is one of the main causes of secondary systemic arterial hypertension. Several non-invasive diagnostic methods for RAS have been used in hypertensive patients, such as color Doppler ultrasound (US). The aim of this study was to assess the sensitivity and specificity of a new renal Doppler US direct-method parameter: the renal-renal ratio (RRR), and compare with the sensitivity and specificity of direct-method conventional parameters: renal peak systolic velocity (RPSV) and renal aortic ratio (RAR), for the diagnosis of severe RAS. METHODS: Our study group included 34 patients with severe arterial hypertension (21 males and 13 females), mean age 54 (± 8.92) years old consecutively evaluated by renal color Doppler ultrasound (US) for significant RAS diagnosis. All of them underwent digital subtraction arteriography (DSA). RAS was significant if a diameter reduction > 50% was found. The parameters measured were: RPSV, RAR and RRR. The RRR was defined as the ratio between RPSV at the proximal or mid segment of the renal artery and RPSV measured at the distal segment of the renal artery. The sensitivity and specificity cutoff for the new RRR was calculated and compared with the sensitivity and specificity of RPSV and RAR. RESULTS: The accuracy of the direct method parameters for significant RAS were: RPSV >200 cm/s with 97% sensitivity, 72% specificity, 81% positive predictive value and 95% negative predictive value; RAR >3 with 77% sensitivity, 90% specificity, 90% positive predictive value and 76% negative predictive value. The optimal sensitivity and specificity cutoff for the new RRR was >2.7 with 97% sensitivity (p < 0.004) and 96% specificity (p < 0.02), with 97% positive predictive value and 97% negative predictive value. CONCLUSION: The new RRR has improved specificity compared with the direct method conventional parameters (RPSV >200cm/s and RAR >3). Both RRR and RPSV show better sensitivity than RAR for the RAS diagnosis
    • …
    corecore