119 research outputs found

    Multi-phase postmortem CT angiography: recognizing technique-related artefacts and pitfalls

    Get PDF
    Background and purpose: Multi-phase postmortem CT angiography (MPMCTA) is increasingly being recognized as a valuable adjunct medicolegal tool to explore the vascular system. Adequate interpretation, however, requires knowledge about the most common technique-related artefacts. The purpose of this study was to identify and index the possible artefacts related to MPMCTA. Material and methods: An experienced radiologist blinded to all clinical and forensic data retrospectively reviewed 49 MPMCTAs. Each angiographic phase, i.e. arterial, venous and dynamic, was analysed separately to identify phase-specific artefacts based on location and aspect. Results: Incomplete contrast filling of the cerebral venous system was the most commonly encountered artefact, followed by contrast agent layering in the lumen of the thoracic aorta. Enhancement or so-called oedematization of the digestive system mucosa was also frequently observed. Conclusion: All MPMCTA artefacts observed and described here are reproducible and easily identifiable. Knowledge about these artefacts is important to avoid misinterpreting them as pathological finding

    Development of a protocol for standardized use of a water-soluble contrast agent with polyethylene glycol in post-mortem CT angiography.

    Get PDF
    Computed tomography angiography (PMCTA) is increasingly used in postmortem cases. Standardized validated protocols permit to compare different PMCTA images and make it more easily to defend a case in court. In addition to the well-known technique by Grabherr et al. (2011) which is using paraffin oil as a carrier substance, water-soluble polyethylene glycol 200 (PEG200) can be used in combination with the contrast agent Accupaque® 300. As to date, there exists no standardized protocol for the use of this contrast agent mixture, the aim of this study was to develop a protocol using it. Between 2012 and 2022, 23 PMCTA with PEG200 and Accupaque®300 were performed at the University Centre of Legal Medicine Lausanne (Switzerland) and the Institute of Forensic Medicine Munich (Germany). The images obtained were evaluated regarding the opacification of the vessels and possible artefacts. The best image quality was obtained with a mixing ratio of 1:15 (Accupaque®300:PEG200) and a perfusion volume of 1000 ml in the arterial, 1400 ml in the venous and 350 ml in the dynamic phase. The infusion rates described by Grabherr et al. were confirmed for the three phases. Overall, the opacification of the vessels was diagnostically sufficient. In 13 cases no opacification of the right coronary artery was observed due to a stratification artefact. By using the PMCTA protocol with PEG200 as a carrier, a good overall image quality can be achieved. This protocol offers the possibility to standardize PMCTA with PEG200

    Temperature dependence of viscosity, relaxation times (T1, T2) and simulated contrast for potential perfusates in post-mortem MR angiography (PMMRA).

    Get PDF
    Developments in post-mortem imaging increasingly focus on addressing recognised diagnostic weaknesses, especially with regard to suspected natural deaths. Post-mortem MR angiography (PMMRA) may offer additional diagnostic information to help address such weaknesses, specifically in the context of sudden cardiac death. Complete filling of the coronary arteries and acceptable contrast with surrounding tissue are essential for a successful approach to PMMRA. In this work, the suitability of different liquids for inclusion in a targeted PMMRA protocol was evaluated. Factors influencing cooling of paraffinum liquidum + Angiofil® (6 %) in cadavers during routine multiphase post-mortem CT angiography were investigated. The temperature dependence of dynamic viscosity (8-20 °C), longitudinal (T1) and transverse (T2) relaxation (1-23 °C) of the proposed liquids was quadratically modelled. The relaxation behaviour of these liquids and MR scan parameters were further investigated by simulation of a radiofrequency (RF)-spoiled gradient echo (GRE) sequence to estimate potentially achievable contrast between liquids and post-mortem tissue at different temperatures across a forensically relevant temperature range. Analysis of the established models and simulations indicated that based on dynamic viscosity (27-33 mPa · s), short T1 relaxation times (155-207 ms) and a minimal temperature dependence over the investigated range of these parameters, paraffin oil and a solution of paraffin oil + Angiofil® (6 %) would be most suitable for post-mortem reperfusion and examination in MRI

    Impact of increasing levels of adaptive statistical iterative reconstruction on image quality in oil-based postmortem CT angiography in coronary arteries.

    Get PDF
    Postmortem multi-detector computed tomography (PMCT) has become an important part in forensic imaging. Modern reconstruction techniques such as iterative reconstruction (IR) are frequently used in postmortem CT angiography (PMCTA). The image quality of PMCTA depends on the strength of IR. For this purpose, we aimed to investigate the impact of different advanced IR levels on the objective and subjective PMCTA image quality. We retrospectively analyzed the coronary arteries of 27 human cadavers undergoing whole-body postmortem CT angiography between July 2017 and March 2018 in a single center. Iterative reconstructions of the coronary arteries were processed in five different level settings (0%; 30%; 50%; 70%; 100%) by using an adaptive statistical IR method. We evaluated the objective (contrast-to-noise ratio (CNR)) and subjective image quality in several anatomical locations. Our results demonstrate that the increasing levels of an IR technique have relevant impact on the image quality in PMCTA scans in forensic postmortem examinations. Higher levels of IR have led to a significant reduction of image noise and therefore to a significant improvement of objective image quality (+ 70%). However, subjective image quality is inferior at higher levels of IR due to plasticized image appearance. Objective image quality in PMCTA progressively improves with increasing level of IR with the best CNR at the highest IR level. However, subjective image quality is best at low to medium levels of IR. To obtain a "classic" image appearance with optimal image quality, PMCTAs should be reconstructed at medium levels of IR

    Gas analysis of exhumed cadavers buried for 30years: a case report about long time alteration

    Get PDF
    Due to important alteration caused by long time decomposition, the gases in human bodies buried for more than a year have not been investigated. For the first time, the results of gas analysis sampled from bodies recently exhumed after 30years are presented. Adipocere formation has prevented the bodies from too important alteration, and gaseous areas were identified. The sampling was performed with airtight syringes assisted by multi-detector computed tomography (MDCT) in those specific areas. The important amount of methane (CH4), coupled to weak amounts of hydrogen (H2) and carbon dioxide (CO2), usual gaseous alteration indicators, have permitted to confirm methanogenesis mechanism for long period of alteration. H2 and CO2 produced during the first stages of the alteration process were consumed through anaerobic oxidation by methanogenic bacteria, generating CH4

    Hydrothermal and volcanic activity found on the southern Mid-Atlantic Ridge

    Get PDF
    The process of plate accretion at mid-ocean ridges, once thought to occur in a relatively simple, magmatic system, has been shown in recent years to possess unexpected layers of complexity [e.g., Cannat, 1996; Escartín and Lin, 1998; Jokat et al., 2003; Michael et al., 2003]. Particularly at lower spreading rates, the magma supply to some or all of the ridge decreases, with the plate spreading motion being taken up instead on faults. The balance between these magmatic and tectonic processes governs such features as the topography, seismic activity location of hydrothermal vents, and degree of chemical exchange between crust and ocean at spreading axes. It therefore has important implications for the hydrothermal marine biosphere and global chemical budgets

    Compositional variation and 226Ra-230Th model ages of axial lavas from the southern Mid-Atlantic Ridge, 8°48′S

    Get PDF
    We present geological observations and geochemical data for the youngest volcanic features on the slow-spreading Mid-Atlantic Ridge at 8°48'S that shows seismic evidence for a thickened crust and excess magma formation. Young lava flows with high sonar reflectivity cover about 14 km2 in the axial rift and were probably erupted from two axial volcanic ridges each of about 3 km in length. Three different lava units occur along an about 11 km long portion of the ridge, and lavas from the northern axial volcanic ridge differ from those of the southern axial volcanic ridge and surrounding lava flows. Basalts from the axial rift flanks and from a pillow mound within the young flows are more incompatible element depleted than those from the young volcanic field. Lavas from this volcanic area have 226Ra-230Th disequilibria model ages of 1,000 and 4,000 years whereas the older lavas from the rift flank and the pillow mound, but also some of the lava field, are older than 8,000 years. Glasses from the northern and southern ends of the southern lava unit indicate up to 100°C cooler magma temperatures than in the center and increased assimilation of hydrothermally altered material. The compositional heterogeneity on a scale of 3 km suggests small magma batches rising vertically from the mantle to the surface without significant lateral flow and mixing. The observations on the 8°48'S lava field support the model of low frequency eruptions from single ascending magma batches that has been developed for slow-spreading ridges

    Non-invasive or minimally invasive autopsy compared to conventional autopsy of suspected natural deaths in adults: a systematic review

    Get PDF
    Objectives: Autopsies are used for healthcare quality control and improving medical knowledge. Because autopsy rates are declining worldwide, various non-invasive or minimally invasive autopsy methods are now being developed. To investigate whether these might replace the invasive autopsies conventionally performed in naturally deceased adults, we systematically reviewed original prospective validation studies. Materials and methods: We searched six databases. Two reviewers independently selected articles and extracted data. Methods and patient groups were too heterogeneous for meaningful meta-analysis of outcomes. Results: Sixteen of 1538 articles met our inclusion criteria. Eight studies used a blinded comparison; ten included less than 30 appropriate cases. Thirteen studies used radiological imaging (seven dealt solely with non-invasive procedures), two thoracoscopy and laparoscopy, and one sampling without imaging. Combining CT and MR was the best non-invasive method (agreement for cause of death: 70 %, 95%CI: 62.6; 76.4), but minimally invasive methods surpassed non-invasive methods. The highest sensitivity for cause of death (90.9 %, 95%CI: 74.5; 97.6, suspected duplicates excluded) was achieved in recent studies combining CT, CT-angiography and biopsies. Conclusion: Minimally invasive autopsies including biopsies performed best. To establish a feasible alternative to conventional autopsy and to increase consent to post-mortem investigations, further research in larger study groups is needed. Key points: • Health care quality control benefits from clinical feedback provided by (alternative) autopsies. • So far, sixteen studies investigated alternative autopsy methods for naturally deceased adults. • Thirteen studies used radiological imaging modalities, eight tissue biopsies, and three CT-angiography. • Combined CT, CT-angiography and biopsies were most sensitive diagnosing cause of death
    corecore