1,006 research outputs found

    An open platform for rapid-prototyping protection and control schemes with IEC 61850

    Get PDF
    Communications is becoming increasingly important to the operation of protection and control schemes. Although offering many benefits, using standards-based communications, particularly IEC 61850, in the course of the research and development of novel schemes can be complex. This paper describes an open-source platform which enables the rapid prototyping of communications-enhanced schemes. The platform automatically generates the data model and communications code required for an intelligent electronic device to implement a publisher-subscriber generic object-oriented substation event and sampled-value messaging. The generated code is tailored to a particular system configuration description (SCD) file, and is therefore extremely efficient at runtime. It is shown here how a model-centric tool, such as the open-source Eclipse Modeling Framework, can be used to manage the complexity of the IEC 61850 standard, by providing a framework for validating SCD files and by automating parts of the code generation process. The flexibility and convenience of the platform are demonstrated through a prototype of a real-time, fast-acting load-shedding scheme for a low-voltage microgrid network. The platform is the first open-source implementation of IEC 61850 which is suitable for real-time applications, such as protection, and is therefore readily available for research and education

    Choice and properties of adaptive and tunable digital boxcar (moving average) filters for power systems and other signal processing applications

    Get PDF
    The humble boxcar (or moving average) filter has many uses, perhaps the most well-known being the Dirichlet kernel inside a short-time discrete Fourier transform. A particularly useful feature of the boxcar filter is the ease of placement of (and tuning of) regular filter zeros, simply by defining (and varying) the time length of the boxcar window. This is of particular use within power system measurements to eliminate harmonics, inter-harmonics and image components from Fourier, Park and Clarke transforms, and other measurements related to power flow, power quality, protection, and converter control. However, implementation of the filter in real-time requires care, to minimise the execution time, provide the best frequency-domain response, know (exactly) the group delay, and avoid cumulative numerical precision errors over long periods. This paper reviews the basic properties of the boxcar filter, and explores different digital implementations, which have subtle differences in performance and computational intensity. It is shown that generally, an algorithm using trapezoidal integration and interpolation has the most desirable characteristics

    Real-time compression of IEC 61869-9 sampled value data

    Get PDF
    Fast-acting, yet cost-effective, communications is critical for smarter grid monitoring, protection, and control. This paper demonstrates a new approach for the real-time compression of Sampled Value (SV) data based on the IEC 61869-9 recommendations. This approach applies simple compression rules, yet yields excellent compression performance---typically compressing data to less than half of the original size. This leads to a significant and beneficial reduction in encoding time (in the merging unit producing the SV data) and decoding time (at the end application), as well as the main benefit of reduced Ethernet transmission times resulting from the reduced frame size. As well as reducing the absolute bandwidth requirements in typical applications, this has system-wide benefits due to reducing Ethernet queuing delays and the consequent network jitter. The approach has been validated on a real-time platform to accurately measure all contributions to the end-to-end delay. This work will help enable low-latency and bandwidth-sensitive applications involving the SV protocol, such as phasor measurement units and wide-area protection

    Power quality analysis in 25 kV 50 Hz AC railway system networks

    Get PDF
    Railway electricity networks are characterised by different power quality (PQ) phenomena from those of transmission and distribution electricity grids Trains are mobile and continuously interact with overhead contact line and other trains, exchanging power during acceleration, coasting and notably during regenerative braking This producer consumer behaviour of the locomotive with the rest of the system deteriorates the PQ of the railway grid

    Power quality measurement and active harmonic power in 25 kV 50 Hz AC railway systems

    Get PDF
    Railway electrical networks rated at 25 kV 50 Hz are characterised by significant levels of voltage and current harmonics. These frequency components are also time varying in nature due to the movement of trains and changing operational modes. Processing techniques used to evaluate harmonic results, although standardised, are not explicitly designed for railway applications, and the smoothing effect that the standard aggregation algorithms have on the measured results is significant. This paper analyses the application accuracy of standardised power quality (PQ) measurement algorithms, when used to measure and evaluate harmonics in railway electrical networks. A shorter aggregation time interval is proposed for railway power quality measurement instruments, which offers more accurate estimated results and improved tracking of time varying phenomena. Harmonic active power present in railway electrical networks is also evaluated in order to quantify the impact it has on the energy accumulated by electrical energy meters installed on-board trains. Analysis performed on 12 train journeys shows significant levels of non-fundamental active power developed for short periods of time. As an energy meter will inadvertently absorb the financial cost of non-fundamental energy produced by other trains or other external power flows, results are provided to support recommendations for future standards to measure only fundamental frequency energy within train energy measurement meters

    Dealing with front-end white noise on differentiated measurements such as frequency and ROCOF in power systems

    Get PDF
    This paper describes the way that white noise (including quantised input section sampling) imparts errors onto frequency and rate-of-change-of-frequency (ROCOF) measurements. The main paper focus concerns the use of filtered heterodyned (i.e. Fourier) analyses for single-phase and 3-phase systems, and the filtered Clarke transform for 3-phase systems. The rules and equations governing the effect of white noise on frequency and ROCOF are formulated for these techniques, explaining the subtle effects of aliasing, splitting signals and noise into their positive and negative frequency components, and the correlation or de-correlation of noise. It is shown that - as expected - for 3-phase AC measurements, averaging 3 single-phase Fourier measurements produces the same performance against noise as using a method based on Clarke’s transform, if identical filtering is used. Furthermore, by understanding the theory behind the frequency and ROCOF measurement processes, it is shown that to achieve the lowest RMS errors, in the presence of front-end white noise (alone, ignoring other dynamic signal and power quality aspects), a filter which provides ~40 dB/decade attenuation (i.e. a 2-boxcar cascade) is recommended for a frequency measurement, but a filter which rolls off at ~60 dB/decade (i.e. a 3-boxcar cascade) is recommended for a ROCOF measurement

    Application of MPLS-TP for transporting power system protection data

    Get PDF
    Power utilities are increasingly dependent on the use of communications networks. These networks are evolving to be packet-based, rather than using conventional Time-Division Multiplexing (TDM) technologies. Transporting current differential protection traffic over a packet network is especially challenging, due to the safety-critical nature of protection, the strict requirements for low delay and low asymmetrical delay, and the extensive use of legacy TDM-based protocols. This paper highlights the key technical characteristics of Multi-Protocol Label Switching-Transport Profile (MPLS-TP), and demonstrates its application for transporting current differential protection traffic. A real-time hardware-in-the-loop testing approach has been used to thoroughly validate the technologies in various configurations. It is demonstrated that MPLS-TP technologies can meet the requirements of current differential protection and other, less critical applications. In particular, it is shown that delay and asymmetrical delay can be controlled through the inherent use of bi-directional paths---even when “hitless” link redundancy is configured. The importance of appropriate traffic engineering, clocking schemes, circuit emulation methods is also demonstrated

    Automatically detecting and correcting errors in power quality monitoring data

    Get PDF
    Dependable power quality (PQ) monitoring is crucial for evaluating the impact of smart grid developments. Monitoring schemes may need to cover a relatively large network area, yet must be conducted in a cost-effective manner. Real-time communications may not be available to observe the status of a monitoring scheme or to provide time synchronization, and therefore undetected errors may be present in the data collected. This paper describes a process for automatically detecting and correcting errors in PQ monitoring data, which has been applied in an actual smart grid project. It is demonstrated how to: unambiguously recover from various device installation errors; enforce time synchronization between multiple monitoring devices and other events by correlation of measured frequency trends; and efficiently visualize PQ data without causing visual distortion, even when some data values are missing. This process is designed to be applied retrospectively to maximize the useful data obtained from a network PQ monitoring scheme, before quantitative analysis is performed. This work therefore ensures that insights gained from the analysis of the data - and subsequent network operation or planning decisions - are also valid. A case study of a UK smart grid project, involving wide-scale distribution system PQ monitoring, demonstrates the effectiveness of these contributions. All source code used for the paper is available for reuse

    Lower Extremity Muscle Strength and Risk of Self-Reported Hip or Knee Osteoarthritis

    Get PDF
    Purpose: The purpose of this study was to investigate the gender-specific longitudinal association between quadriceps strength and self-reported, physician-diagnosed hip or knee osteoarthritis (OA). Methods: Subjects were 3081 community-dwelling adults who were free of OA, joint symptoms and injuries, completed a maximum treadmill exercise test, had isokinetic knee extension and flexion and isotonic leg press strength measurements taken at baseline and returned at least one written follow-up survey. Multivariate logistic regression was used to estimate odds ratios and 95% confidence intervals. Results: Women with moderate or high isokinetic quadriceps strength had a significantly reduced risk (55% to 64%) of hip or knee OA. A similar, nonsignificant trend was noted among men. Moderate isotonic leg press strength was protective for hip or knee osteoarthritis among men only. Conclusions: These results suggest that quadriceps weakness is an independent and modifiable risk factor for lower extremity OA, particularly among women

    Synchronous reference frame interface for geographically distributed real-time simulations

    Get PDF
    The increasing complexity of power systems has warranted the development of geographically distributed real-time simulations (GD-RTS). However, the wide scale adoption of GD-RTS remains a challenge owing to the (i) limitations of state-ofthe- A rt interfaces in reproducing faster dynamics and transients, (ii) lack of an approach to ensure a successful implementation within geographically separated research infrastructures (RIs) and (iii) lack of established evidence of its appropriateness for smart grid applications. To address the limitations in reproduction of faster dynamics and transients, this study presents a synchronous reference frame interface for GD-RTS. By means of a comprehensive performance characterisation, the superior performance of the proposed interface in terms of accuracy (reduced error on average by 60% and faster settling times) and computational complexity has been established. This study further derives the transfer function models for GD-RTS with interface characteristics for analytical stability analysis that ensure stable implementations avoiding the risks associated with multiple RI implementations. Finally, to establish confidence in the proposed interface and to investigate GD-RTS applicability for real-world applications, a GD-RTS implementation between two RIs at the University of Strathclyde is realised to demonstrate inertial support within transmission network model of the Great Britain power system