321 research outputs found

    Leaf color and vine size are related to yield in a phylloxera-infested vineyard

    Get PDF
    The uneven spread of phylloxera infestation and associated vine symptoms in vineyards usually complicates yield estimates and vineyard replacement decisions. In a Cabernet Sauvignon vineyard with AXR#1 rootstock the current season's and following season's yields of 40 vine plots correlated (r ≥ 0.77, p ≤ 0.05) with early to midseason leaf and canopy spectra measured in the field, laboratory and remotely with aircraft-borne sensors

    A low energy optimization of the CERN-NGS neutrino beam for a theta_{13} driven neutrino oscillation search

    Full text link
    The possibility to improve the CERN to Gran Sasso neutrino beam performances for theta_{13} searches is investigated. We show that by an appropriate optimization of the target and focusing optics of the present CNGS design, we can increase the flux of low energy neutrinos by about a factor 5 compared to the current tau optimized focalisation. With the ICARUS 2.35 kton detector at LNGS and in case of negative result, this would allow to improve the limit to sin^22 theta_{13} by an order of magnitude better than the current limit of CHOOZ at Delta m^2 approximately 3 times 10^{-3} eV^2 within 5 years of nominal CNGS running. This is by far the most sensitive setup of the currently approved long-baseline experiments and is competitive with the proposed JHF superbeam.Comment: 19 pages, 8 figure

    Trypanosoma cruzi infection in blood donors

    Get PDF
    INTRODUCTION: Transmission of American trypanossomiasis by transfusion has been reduced by expansion of control measures of blood quality in Brazil. A research project was, therefore, undertaken to evaluate soropositivity for Trypanosoma cruzi infection on blood donors and to compare this rate with those found in 1958 and 1975 in blood banks. METHOD: A transversal study was carried out on blood donors in Londrina, Paraná, Brazil. ELISA and Immunofluorescence were the serological test techniques used in the diagnosis of Trypanosoma cruzi infection. RESULTS AND CONCLUSION: A serumprevalence rate of 1.3% was found with a tendency for positive serum findings for Trypanosoma cruzi infection on blood donors to decrease over Aime (1958, 1975, and 1995).INTRODUÇÃO: A transmissão transfusional da tripanossomíase americana tem-se reduzido no Brasil, com a progressiva ampliação do controle de qualidade do sangue. Nesse sentido, realizou-se pesquisa para avaliar a atual soro-prevalência da infecção por Trypanosoma cruzi em candidatos a doador de sangue em Londrina, Paraná (Brasil), e comparar essa taxa com a encontrada em candidatos a doador estudados em 1958 e 1975, na mesma cidade. MÉTODO: Estudo transversal para determinação da soroprevalência. O imuno-diagnóstico de infecção por Trypanosoma cruzi foi realizado através das técnicas imunoenzimática (ELISA) e imunofluorescência indireta. RESULTADOS E CONCLUSÃO: A taxa de soroprevalência encontrada foi de 1,3%. Foi detectada tendência de queda temporal da taxa de positividade dos testes sorológicos para o diagnóstico de infecção por Trypanosoma cruzi nos bancos de sangue do município estudado nos anos de 1958, 1975 e 1995.Universidade Estadual de LondrinaUniversidade Federal de São Paulo (UNIFESP)UNIFESPSciEL

    Site Layout of the proposed new Hadrons' Injector Chain at CERN

    Get PDF
    The replacement of almost all the LHC injector complex on the Meyrin-site of CERN (Linac2, PSB and PS) is planned within the next 10 years. The layout foreseen for the new accelerators is described in this paper, together with its compatibility with the existing experimental physics facilities. These machines can, after upgrade, supply with high beam power future physics facilities for radioactive ions and/or neutrinos. Their possible layout is also sketched in this document

    Neutrino oscillation physics at an upgraded CNGS with large next generation liquid Argon TPC detectors

    Get PDF
    The determination of the missing Ue3U_{e3} element (magnitude and phase) of the PMNS neutrino mixing matrix is possible via the detection of \numu\to\nue oscillations at a baseline LL and energy EE given by the atmospheric observations, corresponding to a mass squared difference E/LΔm22.5×103eV2E/L \sim \Delta m^2\simeq 2.5\times 10^{-3} eV^2. While the current optimization of the CNGS beam provides limited sensitivity to this reaction, we discuss in this document the physics potential of an intensity upgraded and energy re-optimized CNGS neutrino beam coupled to an off-axis detector. We show that improvements in sensitivity to θ13\theta_{13} compared to that of T2K and NoVA are possible with a next generation large liquid Argon TPC detector located at an off-axis position (position rather distant from LNGS, possibly at shallow depth). We also address the possibility to discover CP-violation and disentangle the mass hierarchy via matter effects. The considered intensity enhancement of the CERN SPS has strong synergies with the upgrade/replacement of the elements of its injector chain (Linac, PSB, PS) and the refurbishing of its own elements, envisioned for an optimal and/or upgraded LHC luminosity programme.Comment: 37 pages, 20 figure

    Infecção por Trypanosoma cruzi em candidatos a doador de sangue

    Get PDF
    INTRODUCTION: Transmission of American trypanossomiasis by transfusion has been reduced by expansion of control measures of blood quality in Brazil. A research project was, therefore, undertaken to evaluate soropositivity for Trypanosoma cruzi infection on blood donors and to compare this rate with those found in 1958 and 1975 in blood banks. METHOD: A transversal study was carried out on blood donors in Londrina, Paraná, Brazil. ELISA and Immunofluorescence were the serological test techniques used in the diagnosis of Trypanosoma cruzi infection. RESULTS AND CONCLUSION: A serumprevalence rate of 1.3% was found with a tendency for positive serum findings for Trypanosoma cruzi infection on blood donors to decrease over Aime (1958, 1975, and 1995).INTRODUÇÃO: A transmissão transfusional da tripanossomíase americana tem-se reduzido no Brasil, com a progressiva ampliação do controle de qualidade do sangue. Nesse sentido, realizou-se pesquisa para avaliar a atual soro-prevalência da infecção por Trypanosoma cruzi em candidatos a doador de sangue em Londrina, Paraná (Brasil), e comparar essa taxa com a encontrada em candidatos a doador estudados em 1958 e 1975, na mesma cidade. MÉTODO: Estudo transversal para determinação da soroprevalência. O imuno-diagnóstico de infecção por Trypanosoma cruzi foi realizado através das técnicas imunoenzimática (ELISA) e imunofluorescência indireta. RESULTADOS E CONCLUSÃO: A taxa de soroprevalência encontrada foi de 1,3%. Foi detectada tendência de queda temporal da taxa de positividade dos testes sorológicos para o diagnóstico de infecção por Trypanosoma cruzi nos bancos de sangue do município estudado nos anos de 1958, 1975 e 1995

    Underground Neutrino Detectors for Particle and Astroparticle Science: the Giant Liquid Argon Charge Imaging ExpeRiment (GLACIER)

    Full text link
    The current focus of the CERN program is the Large Hadron Collider (LHC), however, CERN is engaged in long baseline neutrino physics with the CNGS project and supports T2K as recognized CERN RE13, and for good reasons: a number of observed phenomena in high-energy physics and cosmology lack their resolution within the Standard Model of particle physics; these puzzles include the origin of neutrino masses, CP-violation in the leptonic sector, and baryon asymmetry of the Universe. They will only partially be addressed at LHC. A positive measurement of sin22θ13>0.01\sin^22\theta_{13}>0.01 would certainly give a tremendous boost to neutrino physics by opening the possibility to study CP violation in the lepton sector and the determination of the neutrino mass hierarchy with upgraded conventional super-beams. These experiments (so called ``Phase II'') require, in addition to an upgraded beam power, next generation very massive neutrino detectors with excellent energy resolution and high detection efficiency in a wide neutrino energy range, to cover 1st and 2nd oscillation maxima, and excellent particle identification and π0\pi^0 background suppression. Two generations of large water Cherenkov detectors at Kamioka (Kamiokande and Super-Kamiokande) have been extremely successful. And there are good reasons to consider a third generation water Cherenkov detector with an order of magnitude larger mass than Super-Kamiokande for both non-accelerator (proton decay, supernovae, ...) and accelerator-based physics. On the other hand, a very massive underground liquid Argon detector of about 100 kton could represent a credible alternative for the precision measurements of ``Phase II'' and aim at significantly new results in neutrino astroparticle and non-accelerator-based particle physics (e.g. proton decay).Comment: 31 pages, 14 figure
    corecore