35 research outputs found

    Comparative long-term effects of coronary artery bypass graft surgery and percutaneous transluminal coronary angioplasty on regional coronary flow reserve.

    Full text link
    peer reviewedTo evaluate the relative long-term improvement in coronary artery hemodynamics after revascularization by coronary artery bypass graft surgery (CABG) or percutaneous transluminal coronary angioplasty (PTCA), regional coronary flow reserve (CFR) was measured, by digital computer analysis of 35 mm cine film, in 50 men undergoing cardiac catheterization. CFR (mean +/- SEM) in 12 atherosclerotic arteries before revascularization was 1.02 +/- 0.05. Mean CFR in 29 normal arteries of men with normal coronary arteriograms was significantly higher (2.59 +/- 0.11) than that in 16 atherosclerotic arteries of patients revascularized by CABG (2.02 +/- 0.17, p less than .01) or in 14 atherosclerotic arteries of those revascularized by PTCA (1.97 +/- 0.12, p less than .01). No difference in CFR between the CABG and PTCA groups was found and variables known to influence CFR were similar between groups. Equivalent and significant long-term improvement in coronary artery hemodynamics is provided by CABG or PTCA. We postulate that the difference in CFR in the men with normal arteries and those who underwent revascularization was related to the effects of the general atherosclerotic process, which remain despite successful treatment by these techniques

    Quantitative assessment of global and regional left ventricular function with low-contrast dose digital subtraction ventriculography.

    Full text link
    Few studies have compared the use of low-contrast dose digital subtraction ventriculography with conventional ventriculography for quantitative assessment of both global and regional left ventricular function. Accordingly, 34 patients underwent conventional ventriculography using 36 ml of ionic contrast material and digital ventriculography (mask-mode) using 10 ml of contrast diluted in 10 ml of saline and injected over two seconds. Data from two patients were excluded because of ectopy during cineventriculography and from one because of ectopy during both studies. End-diastolic and end-systolic volumes were calculated from both studies by an area-length method and used to calculate ejection fractions. Regional wall motion was quantitated by the centerline method. Results of linear regression analysis demonstrated high correlations for all parameters (end-diastolic volume, r = 0.85; end-systolic volume, r = 0.93; ejection fraction, r = 0.92; quantitative regional wall motion, r = 0.90). Thus, low-contrast dose digital subtraction ventriculography provides an accurate assessment of both global and regional ventricular function and minimizes the required dose and inherent risks of contrast media

    Analytical Modeling of Heat Deposition in Propellant for Nuclear Thermal Rockets

    No full text
    corecore