332 research outputs found
The dispersion and dissipation of waves in blood vessels
Dispersion and dissipation of waves in blood vessel
A Real-Time Phase Vector Display for EEG Monitoring
A real-time, computer-based, phase vector display system has been developed which will output a vector whose phase is equal to the delay between a trigger and the peak of a function which is quasi-coherent with respect to the trigger. The system also contains a sliding averager which enables the operator to average successive trials before calculating the phase vector. Data collection, averaging and display generation are performed on a LINC-8 computer. Output displays appear on several X-Y CRT display units and on a kymograph camera/oscilloscope unit which is used to generate photographs of time-varying phase vectors or contourograms of time-varying averages of input functions
Fluorescence spectroscopy for identification of atherosclerotic tissue
Objective: Vessel perforation and limited steerability of the laser light are the major limitations of laser angioplasty. To improve steerability fluoresence spectroscopy has been proposed for identification of atherosclerotic plaques. The aim was to investigate this. Methods: Fluorescence spectroscopy with three different excitation wavelengths (325 nm, 380 nm, 450 nm) was tested in an emission range of 400 nm to 600 nm. Intensity ratios at 480/420 nm were determined in different types of blood vessels. Necropsy material from 40 patients (punch biopsies of 4 mm diameter from the coronary and carotid artery as well as from the ascending and descending aorta) was studied spectroscopically. Histological alterations of the vessel wall were assessed by a semiquantitative score (0 to 10 points): (a) normal tissue, 0 to 2 points (mean=0.25; n=38); (b) mild atherosclerotic lesions, 3 to 5 points (mean=3.35; n=39); (c) severe atherosclerotic lesions, ≥ 6 points (mean=6.75; n=43). Results: Best spectroscopic results were obtained with an excitation wavelength of 325 nm. In samples with severe atherosclerotic lesions the fluoresence spectra showed a significant reduction of the emitted wavelength intensities when compared to normal tissue. There was a clear separation of the fluorescence spectra between normal and mild as well as between normal and severe atherosclerotic lesions; normal tissue showed an increased intensity in the range from 420 nm to 540 nm, whereas atherosclerotic lesions had no or only a small peak at 480 nm. There was a significant correlation between the semiquantitative score (n=120) and the fluorescence ratio at 480/420 nm (excitation wavelength 325 nm) with a correlation coefficient of 0.87. The spectroscopic results showed no differences between the samples taken from different types of vessels. Conclusions: Fluorescence spectroscopy allows a reliable identification of normal and atherosclerotic lesions. The close correlation between the emitted light intensity ratio at 480/420 nm and the histological alterations of the vessel wall suggests a relationship between vessel wall fluorescence and the atherosclerotic alterations of the wal
Effects of Multi-Surface Modification on Curie temperature of ferroelectric films
Within the framework of mean field theory, we study the effects of
multi-surface modification on Curie temperature of ferroelectric films using
the transverse Ising model. The general nonlinear equations for Curie
temperature of multi-surface ferroelectric films with arbitrary exchange
constants and transverse fields are derived by the transfer matrix method. As
an example, we consider a film consisting of top surface layers, bulk layers
and bottom surface layers. Two types of surface modifications, modifications of
a surface exchange constant and a surface transverse field are taken into
account. The dependence of Curie temperature on the surface layer numbers, bulk
layer numbers, surface exchange constants, surface transverse fields and bulk
transverse fields is discussed.Comment: 11 pages, 5 figure
The WearARM: Modular, High Performance, Low Power Computing Platform Designed for Integration into Everyday Clothing
Abstract This paper describes a low power, high performance wearable computing plattform, specifically designed for easy integration into everyday clothing. It combines a heterogenous, distributed, user reconfigurable system architecture, advanced power management features and highly miniaturized, mechanically flexible electronic packaging technology. As a result the WearARM system offers high perfomance for a wide range of application in a form factor that allows it to be worn without in any noticeable way interfering with your look and comfort
Temperature Evolution of Sodium Nitrite Structure in a Restricted Geometry
The NaNO nanocomposite ferroelectric material in porous glass was
studied by neutron diffraction. For the first time the details of the crystal
structure including positions and anisotropic thermal parameters were
determined for the solid material, embedded in a porous matrix, in ferro- and
paraelectric phases. It is demonstrated that in the ferroelectric phase the
structure is consistent with bulk data but above transition temperature the
giant growth of amplitudes of thermal vibrations is observed, resulting in the
formation of a "premelted state". Such a conclusion is in a good agreement with
the results of dielectric measurements published earlier.Comment: 4 pages, 4 figure
Swiss clinical practice guidelines on field cancerization of the skin.
Actinic keratosis (AK) affects millions of people worldwide, and its prevalence continues to increase. AK lesions are caused by chronic ultraviolet radiation exposure, and the presence of two or more AK lesions along with photodamage should raise the consideration of a diagnosis of field cancerization. Effective treatment of individual lesions as well as field cancerization is essential for good long-term outcomes. The Swiss Registry of Actinic Keratosis Treatment (REAKT) Working Group has developed clinical practice guidelines for the treatment of field cancerization in patients who present with AK. These guidelines are intended to serve as a resource for physicians as to the most appropriate treatment and management of AK and field cancerization based on current evidence and the combined practical experience of the authors. Treatment of AK and field cancerization should be driven by consideration of relevant patient, disease, and treatment factors, and appropriate treatment decisions will differ from patient to patient. Prevention measures and screening recommendations are discussed, and special considerations related to management of immunocompromised patients are provided
Sleep analysis for elderly care using a low-resolution visual sensor network
Nearly half of the senior citizens report difficulty initiating and maintaining sleep. Frequent visits to the bathroom in the middle of the night is considered as one of the major reasons for sleep disorder. This leads to serious diseases such as depression and diabetes. In this paper, we propose to use a network of cheap low-resolution visual sensors (30 x 30 pixels) for long-term activity analysis of a senior citizen in a service flat. The main focus of our research is on elderly behaviour analysis to detect health deterioration. Specifically, this paper treats the analysis of sleep patterns. Firstly, motion patterns are detected. Then, a rule-based approach on the motion patterns is proposed to determine the wake up time and sleep time. The nightly bathroom visit is identified using a classification-based model. In our evaluation, we performed experiments on 10 months of real-life data. The ground truth is collected from the diaries in which the senior citizen wrote down his sleep time and wake up time. The results show accurate extraction of the sleep durations with an overall Mean Absolute Error (MAE) of 22.91 min and Spearman correlation coefficient of 0.69. Finally, the nightly bathroom visits analysis indicate sleep disorder in several nights
CD20 and CD19 targeted vectors induce minimal activation of resting B lymphocytes
B lymphocytes are an important cell population of the immune system. However, until recently it was not possible to transduce resting B lymphocytes with retro- or lentiviral vectors, making them unsusceptible for genetic manipulations by these vectors. Lately, we demonstrated that lentiviral vectors pseudotyped with modified measles virus (MV) glycoproteins hemagglutinin, responsible for receptor recognition, and fusion protein were able to overcome this transduction block. They use either the natural MV receptors, CD46 and signaling lymphocyte activation molecule (SLAM), for cell entry (MV-LV) or the vector particles were further modified to selectively enter via the CD20 molecule, which is exclusively expressed on B lymphocytes (CD20-LV). It has been shown previously that transduction by MV-LV does not induce B lymphocyte activation. However, if this is also true for CD20-LV is still unknown. Here, we generated a vector specific for another B lymphocyte marker, CD19, and compared its ability to transduce resting B lymphocytes with CD20-LV. The vector (CD19ds-LV) was able to stably transduce unstimulated B lymphocytes, albeit with a reduced efficiency of about 10% compared to CD20-LV, which transduced about 30% of the cells. Since CD20 as well as CD19 are closely linked to the B lymphocyte activation pathway, we investigated if engagement of CD20 or CD19 molecules by the vector particles induces activating stimuli in resting B lymphocytes. Although, activation of B lymphocytes often involves calcium influx, we did not detect elevated calcium levels. However, the activation marker CD71 was substantially up-regulated upon CD20-LV transduction and most importantly, B lymphocytes transduced with CD20-LV or CD19ds-LV entered the G1b phase of cell cycle, whereas untransduced or MV-LV transduced B lymphocytes remained in G0. Hence, CD20 and CD19 targeting vectors induce activating stimuli in resting B lymphocytes, which most likely renders them susceptible for lentiviral vector transduction
Fluorescence spectroscopy for identification of atherosclerotic tissue
Objective: Vessel perforation and limited steerability of the laser light are the major limitations of laser angioplasty. To improve steerability fluoresence spectroscopy has been proposed for identification of atherosclerotic plaques. The aim was to investigate this. Methods: Fluorescence spectroscopy with three different excitation wavelengths (325 nm, 380 nm, 450 nm) was tested in an emission range of 400 nm to 600 nm. Intensity ratios at 480/420 nm were determined in different types of blood vessels. Necropsy material from 40 patients (punch biopsies of 4 mm diameter from the coronary and carotid artery as well as from the ascending and descending aorta) was studied spectroscopically. Histological alterations of the vessel wall were assessed by a semiquantitative score (0 to 10 points): (a) normal tissue, 0 to 2 points (mean=0.25; n=38); (b) mild atherosclerotic lesions, 3 to 5 points (mean=3.35; n=39); (c) severe atherosclerotic lesions, ≥ 6 points (mean=6.75; n=43). Results: Best spectroscopic results were obtained with an excitation wavelength of 325 nm. In samples with severe atherosclerotic lesions the fluoresence spectra showed a significant reduction of the emitted wavelength intensities when compared to normal tissue. There was a clear separation of the fluorescence spectra between normal and mild as well as between normal and severe atherosclerotic lesions; normal tissue showed an increased intensity in the range from 420 nm to 540 nm, whereas atherosclerotic lesions had no or only a small peak at 480 nm. There was a significant correlation between the semiquantitative score (n=120) and the fluorescence ratio at 480/420 nm (excitation wavelength 325 nm) with a correlation coefficient of 0.87. The spectroscopic results showed no differences between the samples taken from different types of vessels. Conclusions: Fluorescence spectroscopy allows a reliable identification of normal and atherosclerotic lesions. The close correlation between the emitted light intensity ratio at 480/420 nm and the histological alterations of the vessel wall suggests a relationship between vessel wall fluorescence and the atherosclerotic alterations of the wal
- …