35 research outputs found

    Post irradiation evaluation of inconel alloy 718 beam window

    Get PDF
    Introduction Annealed Inconel 718 alloy was chosen for the beam window at the Los Alamos Neutron Science Center (LANSCE) Isotope Production Facility (IPF) [1]. The window was replaced after 5 years of operation. Mechanical properties and microstructure changes were measured to assess its expected lifetime. Material and Methods A cutting plan was developed based on the IPF rasterred beam profile (FIG. 1). 3-mm OD samples were cut out from the window and thinned to 0.25-mm thick. Shear punch tests were per-formed at 25 °C on 21 samples to quantify shear yield, ultimate shear stress, and ductility. From 1-mm OD, 0.25-mm thick shear punched out disks, 4 TEM specimens of ~30×10×2 μm were obtained using standard FIB lift-out techniques. TEM was performed on an FEI Tecnai TF30-FEG operating at 300 kV. Results and Conclusions TABLE 1 shows MCNPX tally results of accumulated dpa, He and H content from both protons and neutrons fluences and ANSYS steady-state irradiation temperature for the 3-mm OD samples [2]. These peak values are at the peak density of Typically increases in shear yield and shear maximum stress occur with increasing dose. In this case, highest shear yield and ultimate stress was on the lowest dose samples at the outer edge (FIG. 2). Optical microscopy images of the fracture surfaces on the shear punched out disks show no significant change in the fracture mode or reduction in ductility in the un-irradiated, high and low dose irradiated samples. One un-irradiated and 4 irradiated samples (5, E, 16 and 19) were selected for TEM analysis. Figure 3 shows bright field TEM images of an un-irradiated, high and low dose irradiated samples. Un-irradiated sample shows some dislocations and some large precipitates. The high dose sample #5 (~11 dpa, 122 oC) shows small loops and dislocations (left and center images) and no γ\' or γ\'\' precipitates in SAD from z = [011] (right image). Low dose sample #19 (~0.7 dpa, 40 oC) shows a high density of dislocation loops (left image), high density of H/He bubbles (center image) and presence of γ\'\' precipitates in SAD from z = [011] (right image). Radiation induced-hardening is highest at the low dose region in the outer most edge. The hardening from γ\'\' precipitates is determined to be more pronounced than that from trapped bubbles. The lack of significant hardening in the highest dose region is attributed to a lower dis-location density and no γ” precipitates or bubbles [3]. Identification of H or He bubbles and the higher accumulation of these bubbles in the low dose region (no direct beam hitting) warrant further studies. Despite the evidence of irradiation-induced hardening, this spent beam window appears to retain useful ductility after 5 years in service. At the conclusion of 2013 run cycle, the current in-service beam window had reached the same dpa as of the spent window. We plan to extend the service of the current in-service window until it reaches its intended design threshold limit of ~20 dpa (in the highest dose region). Additional measurements at higher dpa values will enable better decision-making in managing risks of the window failure

    Do Twin Boundaries Always Strengthen Metal Nanowires?

    Get PDF
    It has been widely reported that twin boundaries strengthen nanowires regardless of their morphology—that is, the strength of nanowires goes up as twin spacing goes down. This article shows that twin boundaries do not always strengthen nanowires. Using classical molecular dynamics simulations, the authors show that whether twin boundaries strengthen nanowires depends on the necessary stress for dislocation nucleation, which in turn depends on surface morphologies. When nanowires are circular cylindrical, the necessary stress of dislocation nucleation is high and the presence of twin boundaries lowers this stress; twin boundaries soften nanowires. In contrast, when nanowires are square cylindrical, the necessary stress of dislocation nucleation is low, and a higher stress is required for dislocations to penetrate twin boundaries; they strengthen nanowires

    Effect of shock loading on the microstructure, mechanical properties and grain boundary characteristics of HT-9 ferritic/martensitic steels

    No full text
    The microstructural changes and mechanical response of an HT-9 sample shock loaded to a peak pressure of 11 GPa have been investigated by TEM, XRD, microhardness and EBSD techniques. Dislocation densities obtained by both direct measurements (via TEM) and indirect calculations (by XRD and hardness) indicate that shock loading results in similar to 2-3 fold increase in dislocation density. TEM analyses show that the shape, and density of the dislocations change after shock loading. In addition, shock loading causes local plastic deformation of the continuous parallel lath structure in some regions, together with an overall decrease in the aspect ratio of laths due to local plastic deformation and lath fragmentation. As a result of XRD analyses, the fraction of edge dislocations is determined to increase by similar to 24% after shock loading. Furthermore, hardness increases by similar to 40 HV after shock loading due to the increased dislocation density. EBSD analyses show that the fraction of CSL boundaries decreases by similar to 5-10% as a result of shock loading. Published by Elsevier B.V

    Effect of tube processing methods on microstructure, mechanical properties and irradiation response of 14YWT nanostructured ferritic alloys

    No full text
    In this research, innovative thermal spray deposition (Process I) and conventional hot extrusion processing (Process II) methods have been used to produce thin walled tubing (similar to 0.5 mm wall thickness) out of 14YWT, a nanostructured ferritic alloy. The effects of processing methods on the microstructure, mechanical properties and irradiation response have been investigated by using scanning electron microscopy (SEM), transmission electron microscopy (TEM) and, micro- and nano-hardness techniques. It has been found that these two processes have a significant effect on the microstructure and mechanical properties of the as-fabricated 14YWT tubes. Even though both processing methods yield the formation of various size Y-Ti-O particles, the conventional hot extrusion method results in a microstructure with smaller, homogenously distributed nano-oxides (NOs, Y-Ti-O particles < 5 nm) with higher density. Therefore, Process II tubes exhibit twice the hardness of Process I tubes. It has also been found that these two tremendously different initial microstructures strongly affect irradiation response in these tubes under extremely high dose ion irradiations up to 1100 peak dpa at 450 degrees C. The finer, denser and homogenously distributed NOs in the Process II tube result in a reduction in swelling by two orders of magnitude. On the other hand, inhomogeneity of the initial microstructure in the Process I tube leads to large variations in both swelling and irradiation induced hardening. Moreover, hardening mechanisms before and after irradiation were measured and compared with detailed calculations. This study clearly indicates the crucial effect of initial microstructure on radiation response of 14YWT alloys. Published by Elsevier Ltd on behalf of Acta Materialia Inc

    Post irradiation evaluation of inconel alloy 718 beam window

    Get PDF
    Introduction Annealed Inconel 718 alloy was chosen for the beam window at the Los Alamos Neutron Science Center (LANSCE) Isotope Production Facility (IPF) [1]. The window was replaced after 5 years of operation. Mechanical properties and microstructure changes were measured to assess its expected lifetime. Material and Methods A cutting plan was developed based on the IPF rasterred beam profile (FIG. 1). 3-mm OD samples were cut out from the window and thinned to 0.25-mm thick. Shear punch tests were per-formed at 25 °C on 21 samples to quantify shear yield, ultimate shear stress, and ductility. From 1-mm OD, 0.25-mm thick shear punched out disks, 4 TEM specimens of ~30×10×2 μm were obtained using standard FIB lift-out techniques. TEM was performed on an FEI Tecnai TF30-FEG operating at 300 kV. Results and Conclusions TABLE 1 shows MCNPX tally results of accumulated dpa, He and H content from both protons and neutrons fluences and ANSYS steady-state irradiation temperature for the 3-mm OD samples [2]. These peak values are at the peak density of Typically increases in shear yield and shear maximum stress occur with increasing dose. In this case, highest shear yield and ultimate stress was on the lowest dose samples at the outer edge (FIG. 2). Optical microscopy images of the fracture surfaces on the shear punched out disks show no significant change in the fracture mode or reduction in ductility in the un-irradiated, high and low dose irradiated samples. One un-irradiated and 4 irradiated samples (5, E, 16 and 19) were selected for TEM analysis. Figure 3 shows bright field TEM images of an un-irradiated, high and low dose irradiated samples. Un-irradiated sample shows some dislocations and some large precipitates. The high dose sample #5 (~11 dpa, 122 oC) shows small loops and dislocations (left and center images) and no γ\' or γ\'\' precipitates in SAD from z = [011] (right image). Low dose sample #19 (~0.7 dpa, 40 oC) shows a high density of dislocation loops (left image), high density of H/He bubbles (center image) and presence of γ\'\' precipitates in SAD from z = [011] (right image). Radiation induced-hardening is highest at the low dose region in the outer most edge. The hardening from γ\'\' precipitates is determined to be more pronounced than that from trapped bubbles. The lack of significant hardening in the highest dose region is attributed to a lower dis-location density and no γ” precipitates or bubbles [3]. Identification of H or He bubbles and the higher accumulation of these bubbles in the low dose region (no direct beam hitting) warrant further studies. Despite the evidence of irradiation-induced hardening, this spent beam window appears to retain useful ductility after 5 years in service. At the conclusion of 2013 run cycle, the current in-service beam window had reached the same dpa as of the spent window. We plan to extend the service of the current in-service window until it reaches its intended design threshold limit of ~20 dpa (in the highest dose region). Additional measurements at higher dpa values will enable better decision-making in managing risks of the window failure
    corecore