1,078 research outputs found

    Rapid selection of specific MAP kinase-binders from designed ankyrin repeat protein libraries

    Get PDF
    We describe here the rapid selection of specific MAP-kinase binders from a combinatorial library of designed ankyrin repeat proteins (DARPins). A combined in vitro/in vivo selection approach, based on ribosome display and the protein fragment complementation assay (PCA), yielded a large number of different binders that are fully functional in the cellular cytoplasm. Ribosome-display selection pools of four successive selection rounds were examined to monitor the enrichment of JNK2-specific DARPins. Surprisingly, only one round of ribosome display with subsequent PCA selection of this pool was necessary to isolate a first specific binder with micromolar affinity. After only two rounds of ribosome-display selection followed by PCA, virtually all DARPins showed JNK2-specific binding, with affinities in the low nanomolar range. The enrichment factor of ribosome display thus approaches 105 per round. In a second set of experiments, similar results were obtained with the kinases JNK1 and p38 as targets. Again, almost all investigated DARPins obtained after two rounds of ribosome display showed specific binding to the targets used, JNK1 or p38. In all three selection experiments the identified DARPins possess very high specificity for the target kinase. Taken together, the combination of ribosome display and PCA selections allowed the identification of large pools of binders at unparalleled speed. Furthermore, DARPins are applicable in intracellular selections and immunoprecipitations from the extract of eukaryotic cell

    Design of percutaneous transluminal coronary angioplasty balloon catheters.

    Get PDF
    BACKGROUND Eight commercially available percutaneous transluminal coronary angioplasty (PTCA), including semi-compliant and non-compliant balloons, have been assessed in detail on their tip, balloon, shaft, RX-Port, and hypotube design. Important performance characteristics such as tip deformation, balloon elongation, and deflation rate have been quantified. METHODS Five catheters of each model were evaluated during various tests. The robustness of the tips was evaluated through compression, measuring any occurrence of damage. The longitudinal growth of the balloons was recorded during inflation up to Rated Burst Pressure (RBP). The forces required to move the catheter forward and retract it into the guide catheter were measured in a simulated use test setup. The deflation behavior was studied by measuring extracted contrast media over time. Furthermore, balloon compliance and catheter dimensions were investigated. RESULTS The outer dimensions of the catheter were found to be smallest at the hypotube (0.59-0.69 mm) and highest at the balloon, respectively, the crossing profile (0.9-1.2 mm). The tip diameter increased after compression by 1.7-22%. Cross-sections of the folded balloons revealed a tri- and two-fold, respectively. The measured balloon elongation ranged from 0.6 to 2.0 mm. After the inflation of the balloon, an increase in friction between the guide wire and the catheter was observed on four catheters. A maximum increase of 0.12 N to 1.07 N was found. Cross-sections of the RX-Port revealed a semicircular-shaped inflation lumen and a circular guide wire lumen. The measured deflation rate ranged from 0.004 to 0.013 µL/s, resulting in an estimated balloon deflation time of 10.2-28.1 s. CONCLUSION This study provides valuable insights into the design characteristics of RX PTCA balloon catheters, which can contribute to facilitating the development of improved catheter designs and enhancing clinical outcomes. Distinctions between SC and NC catheters, such as balloon performance and dimensions, are evident. It is important to note that no single catheter excels in all aspects, as each possesses unique strengths. Therefore, it is essential to consider individual intervention requirements when selecting a catheter. The research also identifies specific catheter weaknesses, such as reduced wall thickness, fringes at the tip, and reduced performance characteristics

    Use of Diabetes Data Management Software Reports by Health Care Providers, Patients With Diabetes, and Caregivers Improves Accuracy and Efficiency of Data Analysis and Interpretation Compared With Traditional Logbook Data: First Results of the Accu-Chek C

    Get PDF
    We assessed users’ proficiency and efficiency in identifying and interpreting self-monitored blood glucose (SMBG), insulin, and carbohydrate intake data using data management software reports compared with standard logbooks. This prospective, self-controlled, randomized study enrolled insulin-treated patients with diabetes (PWDs) (continuous subcutaneous insulin infusion [CSII] and multiple daily insulin injection [MDI] therapy), patient caregivers [CGVs]) and health care providers (HCPs) who were naïve to diabetes data management computer software. Six paired clinical cases (3 CSII, 3 MDI) and associated multiple-choice questions/answers were reviewed by diabetes specialists and presented to participants via a web portal in both software report (SR) and traditional logbook (TL)  formats. Participant response time and accuracy were documented and assessed. Participants completed a preference questionnaire at study completion. All participants (54 PWDs, 24 CGVs, 33 HCPs) completed the cases. Participants achieved greater accuracy (assessed by percentage of accurate answers) using the SR versus TL formats: PWDs, 80.3 (13.2)% versus 63.7 (15.0)%, P < .0001; CGVs, 84.6 (8.9)% versus 63.6 (14.4)%, P <.0001; HCPs, 89.5 (8.0)% versus 66.4 (12.3)%, P < .0001. Participants spent less time (minutes) with each case using the SR versus TL formats: PWDs, 8.6 (4.3) versus 19.9 (12.2), P < .0001; CGVs, 7.0 (3.5) versus 15.5 (11.8), P = .0005; HCPs, 6.7 (2.9) versus 16.0 (12.0), P < .0001. The majority of participants preferred using the software reports versus logbook data. Use of the Accu-Chek Connect Online software reports enabled  PWDs, CGVs, and HCPs, naïve to diabetes data management software, to identify and utilize key diabetes information with significantly greater  accuracy and efficiency compared with traditional logbook information. Use of SRs was preferred over logbooks.Keywords: diabetes software, insulin, self-management, self-monitoring of blood glucose, SMB

    Tissue Expression and Actin Binding of a Novel N-Terminal Utrophin Isoform

    Get PDF
    Utrophin and dystrophin present two large proteins that link the intracellular actin cytoskeleton to the extracellular matrix via the C-terminal-associated protein complex. Here we describe a novel short N-terminal isoform of utrophin and its protein product in various rat tissues (N-utro, 62 kDa, amino acids 1–539, comprising the actin-binding domain plus the first two spectrin repeats). Using different N-terminal recombinant utrophin fragments, we show that actin binding exhibits pronounced negative cooperativity (affinity constants K1 = ∼5 × 106 and K2 = ∼1 × 105 M−1) and is Ca2+-insensitive. Expression of the different fragments in COS7 cells and in myotubes indicates that the actin-binding domain alone binds exlusively to actin filaments. The recombinant N-utro analogue binds in vitro to actin and in the cells associates to the membranes. The results indicate that N-utro may be responsible for the anchoring of the cortical actin cytoskeleton to the membranes in muscle and other tissues

    Reaching absent and refusing individuals during home-based HIV testing through self-testing-at what cost?

    Get PDF
    Introduction: In the HOSENG trial (NCT03598686), the secondary distribution of oral self-tests for persons absent or refusing to test during a home-based HIV testing campaign in rural Lesotho resulted in an increase in testing coverage of 21% compared to a testing campaign without secondary distribution. This study aims to determine the per patient costs of both HOSENG trial arms. Method: We conducted a micro-costing study to estimate the cost of home-based HIV testing with (HOSENG intervention arm) and without (HOSENG control arm) secondary self-test distribution from a provider's perspective. A mixture of top-down and bottom-up costing was used. We estimated both the financial and economic per patient costs of each possible testing cascade scenario. The costs were adjusted to 2018 US.Results:TheoverallprovidercostfordeliveringthehomebasedHIVtestingwithsecondarydistributionwasUS. Results: The overall provider cost for delivering the home-based HIV testing with secondary distribution was US36,481 among the 4,174 persons enumerated and 3,094 eligible for testing in the intervention villages compared to US28,620for3,642personsenumeratedand2,727eligiblefortestinginthecontrol.ThecostperpersoneligiblefortestingwasUS28,620 for 3,642 persons enumerated and 2,727 eligible for testing in the control. The cost per person eligible for testing was US11.79 in the intervention vs. US10.50inthecontrol.Thisdifferencewasmainlydrivenbythecostofdistributedoralselftests.Thecostperpersontestedwas,however,lowerininterventionvillages(US10.50 in the control. This difference was mainly driven by the cost of distributed oral self-tests. The cost per person tested was, however, lower in intervention villages (US15.70 vs. US22.15)duetothehighertestingcoverageachievedthroughselftestdistribution.ThecostperpersonconfirmednewHIV+wasUS22.15) due to the higher testing coverage achieved through self-test distribution. The cost per person confirmed new HIV+ was US889.79 in the intervention and US$753.17 in the control. Conclusion: During home-based HIV testing in Lesotho, the secondary distribution of self-tests for persons absent or refusing to test during the visit reduced the costs per person tested and thus presents a promising add-on for such campaigns. Trial Registration:https://ClinicalTrials.gov/, identifier: NCT03598686

    Influence of crack history on the stable tearing behavior of a thin-sheet material with multiple cracks

    Get PDF
    Fracture tests were conducted on 2.3mm thick, 305mm wide sheets of 2024-T3 aluminum alloy with from one to five collinear cracks. The cracks were introduced (crack history) into the specimens by three methods: saw cutting, fatigue precracking at a low stress range, and fatigue precracking at a high stress range. For the single crack tests, the initial crack history influenced the stress required for the onset of stable crack growth and the first 10mm of crack growth. The effect on failure stress was about 4 percent or less. For the multiple crack tests, the initial crack history was shown to cause differences of more than 20 percent in the link-up stress and 13 percent in failure stress. An elastic-plastic finite element analysis employing the CTOA fracture criterion was used to predict the fracture behavior of the single and multiple crack tests. The numerical predictions were within 7 percent of the observed link-up and failure stress in all the tests
    corecore