3,520 research outputs found
Radio Detection of Cosmic Ray Extensive Air Showers: present status of the CODALEMA experiment
Data acquisition and analysis for the CODALEMA experiment, in operation for
more than one year, has provided improved knowledge of the characteristics of
this new device. At the same time, an important effort has been made to develop
processing techniques for extracting transient signals from data containing
interference.Comment: september 200
Radiodetection of Cosmic Ray Extensive Air Showers
We present the characteristics and performance of a demonstration experiment
devoted to the observation of ultra high- energy cosmic ray extensive air
showers using a radiodetection technique. In a first step, one antenna narrowed
band filtered acting as trigger, with a 4 threshold above sky
background-level, was used to tag any radio transient in coincidence on the
antenna array. Recently, the addition of 4 particle detectors has allowed us to
observe cosmic ray events in coincidence with antennas
Experimental evidence of thermal fluctuations on the X-ray absorption near-edge structure at the aluminum K-edge
After a review of temperature-dependent experimental x-ray absorption
near-edge structure (XANES) and related theoretical developments, we present
the Al K-edge XANES spectra of corundum and beryl for temperature ranging from
300K to 930K. These experimental results provide a first evidence of the role
of thermal fluctuation in XANES at the Al K-edge especially in the pre-edge
region. The study is carried out by polarized XANES measurements of single
crystals. For any orientation of the sample with respect to the x-ray beam, the
pre-edge peak grows and shifts to lower energy with temperature. In addition
temperature induces modifications in the position and intensities of the main
XANES features. First-principles DFT calculations are performed for both
compounds. They show that the pre-edge peak originates from forbidden 1s to 3s
transitions induced by vibrations. Three existing theoretical models are used
to take vibrations into account in the absorption cross section calculations:
i) an average of the XANES spectra over the thermal displacements of the
absorbing atom around its equilibrium position, ii) a method based on the crude
Born-Oppenheimer approximation where only the initial state is averaged over
thermal displacements, iii) a convolution of the spectra obtained for the atoms
at the equilibrium positions with an approximate phonon spectral function. The
theoretical spectra so obtained permit to qualitatively understand the origin
of the spectral modifications induced by temperature. However the correct
treatment of thermal fluctuation in XANES spectroscopy requires more
sophisticated theoretical tools
Radio Detection of Cosmic Ray Air Showers with Codalema
Studies of the radio detection of Extensive Air Showers is the goal of the
demonstrative experiment CODALEMA. Previous analysis have demonstrated that
detection around eV was achieved with this set-up. New results
allow for the first time to study the topology of the electric field associated
to EAS events on a event by event basis.Comment: 6 pages, 4 figures Proceedings of the Rencontres de Moriond, Very
High Energy Phenomena in the Universe, La Thuile, Italy (March 12-19, 2005
Refractory hypoglycaemia in a dog infected with Trypanosoma congolense
A 20 kg German shepherd dog was presented to a French veterinary teaching hospital for seizures and hyperthermia. The dog had returned 1 month previously from a six-month stay in Senegal and sub-Saharan Africa. Biochemistry and haematology showed severe hypoglycaemia (0.12 g/L), anaemia and thrombocytopenia. Despite administration of large amounts of glucose (30 mL of 30% glucose IV and 10 mL of 70% sucrose by gavage tube hourly), 26 consecutive blood glucose measurements were below 0.25 g/L (except one). Routine cytological examination of blood smears revealed numerous free extracytoplasmic protozoa consistent with Trypanosoma congolense. PCR confirmed a Trypanosoma congolense forest-type infection. Treatment consisted of six injections of pentamidine at 48-hour intervals. Trypanosomes had disappeared from the blood smears four days following the first injection. Clinical improvement was correlated with the normalization of laboratory values. The infection relapsed twice and the dog was treated again; clinical signs and parasites disappeared and the dog was considered cured; however, 6 years after this incident, serological examination by ELISA T. congolense was positive. The status of this dog (infected or non-infected) remains unclear. Hypoglycaemia was the most notable clinical feature in this case. It was spectacular in its severity and in its refractory nature; glucose administration seemed only to feed the trypanosomes, indicating that treatment of hypoglycaemia may in fact have been detrimental
Radio Detection of Extensive Air Showers with CODALEMA
The principle and performances of the CODALEMA experimental device, set up to
study the possibility of high energy cosmic rays radio detection, are
presented. Radio transient signals associated to cosmic rays have been
identified, for which arrival directions and shower's electric field topologies
have been extracted from the antenna signals. The measured rate, about 1 event
per day, corresponds to an energy threshold around 5.10^16 eV. These results
allow to determine the perspectives offered by the present experimental design
for radiodetection of UHECR at a larger scale.Comment: 4 pages and 3 figures. To appear in the Proceedings of the 29th ICRC,
Pune (2005
Radioelectric Field Features of Extensive Air Showers Observed with CODALEMA
Based on a new approach to the detection of radio transients associated with
extensive air showers induced by ultra high energy cosmic rays, the
experimental apparatus CODALEMA is in operation, measuring about 1 event per
day corresponding to an energy threshold ~ 5. 10^16 eV. Its performance makes
possible for the first time the study of radio-signal features on an
event-by-event basis. The sampling of the magnitude of the electric field along
a 600 meters axis is analyzed. It shows that the electric field lateral spread
is around 250 m (FWHM). The possibility to determine with radio both arrival
directions and shower core positions is discussed.Comment: Accepted for publication in Astroparticle Physic
- …
