122 research outputs found

    Quasi-buckling of micromachined beams

    Get PDF
    Buckling of structures with imperfections, quasi-buckling (QB), is studied. At the bifurcation load, these structures show a smooth transition into one of the stable postbuckling equilibrium states, instead of the traditional sudden change in deflection characteristics. QB structures can show the classical snap-through buckling behaviour, i.e., a sudden change of postbuckling equilibrium state. The QB is described with a generalized temperature, Tg, representing the compression of the structure. Imperfections and distributed deflection loads are represented by a generalized pressure, pg. Experiments on micromachined beams, exposed to heating (Tg) and to a Lorentz force (pg), verify that the QB phenomena can efficiently transfer a longitudinal stress into a transversal deflection, with a scale-factor depending on both Tg and pg

    Modeling and Experimental Study on Characterization of Micromachined Thermal Gas Inertial Sensors

    Get PDF
    Micromachined thermal gas inertial sensors based on heat convection are novel devices that compared with conventional micromachined inertial sensors offer the advantages of simple structures, easy fabrication, high shock resistance and good reliability by virtue of using a gaseous medium instead of a mechanical proof mass as key moving and sensing elements. This paper presents an analytical modeling for a micromachined thermal gas gyroscope integrated with signal conditioning. A simplified spring-damping model is utilized to characterize the behavior of the sensor. The model relies on the use of the fluid mechanics and heat transfer fundamentals and is validated using experimental data obtained from a test-device and simulation. Furthermore, the nonideal issues of the sensor are addressed from both the theoretical and experimental points of view. The nonlinear behavior demonstrated in experimental measurements is analyzed based on the model. It is concluded that the sources of nonlinearity are mainly attributable to the variable stiffness of the sensor system and the structural asymmetry due to nonideal fabrication

    INTERFACE Toolkit: A New Tool for Building IVAs

    Full text link

    Effect of Axial Force on the Performance of Micromachined Vibratory Rate Gyroscopes

    Get PDF
    It is reported in the published literature that the resonant frequency of a silicon micromachined gyroscope decreases linearly with increasing temperature. However, when the axial force is considerable, the resonant frequency might increase as the temperature increases. The axial force is mainly induced by thermal stress due to the mismatch between the thermal expansion coefficients of the structure and substrate. In this paper, two types of micromachined suspended vibratory gyroscopes with slanted beams were proposed to evaluate the effect of the axial force. One type was suspended with a clamped-free (C-F) beam and the other one was suspended with a clamped-clamped (C-C) beam. Their drive modes are the bending of the slanted beam, and their sense modes are the torsion of the slanted beam. The relationships between the resonant frequencies of the two types were developed. The prototypes were packaged by vacuum under 0.1 mbar and an analytical solution for the axial force effect on the resonant frequency was obtained. The temperature dependent performances of the operated mode responses of the micromachined gyroscopes were measured. The experimental values of the temperature coefficients of resonant frequencies (TCF) due to axial force were 101.5 ppm/°C for the drive mode and 21.6 ppm/°C for the sense mode. The axial force has a great influence on the modal frequency of the micromachined gyroscopes suspended with a C-C beam, especially for the flexure mode. The quality factors of the operated modes decreased with increasing temperature, and changed drastically when the micromachined gyroscopes worked at higher temperatures

    Uncertainty estimation for operational ocean forecast products-a multi-model ensemble for the North Sea and the Baltic Sea

    Get PDF
    Multi-model ensembles for sea surface temperature (SST), sea surface salinity (SSS), sea surface currents (SSC), and water transports have been developed for the North Sea and the Baltic Sea using outputs from several operational ocean forecasting models provided by different institutes. The individual models differ in model code, resolution, boundary conditions, atmospheric forcing, and data assimilation. The ensembles are produced on a daily basis. Daily statistics are calculated for each parameter giving information about the spread of the forecasts with standard deviation, ensemble mean and median, and coefficient of variation. High forecast uncertainty, i.e., for SSS and SSC, was found in the Skagerrak, Kattegat (Transition Area between North Sea and Baltic Sea), and the Norwegian Channel. Based on the data collected, longer-term statistical analyses have been done, such as a comparison with satellite data for SST and evaluation of the deviation between forecasts in temporal and spatial scale. Regions of high forecast uncertainty for SSS and SSC have been detected in the Transition Area and the Norwegian Channel where a large spread between the models might evolve due to differences in simulating the frontal structures and their movements. A distinct seasonal pattern could be distinguished for SST with high uncertainty between the forecasts during summer. Forecasts with relatively high deviation from the multi-model ensemble (MME) products or the other individual forecasts were detected for each region and each parameter. The comparison with satellite data showed that the error of the MME products is lowest compared to those of the ensemble members

    Tibio-femoral joint constraints for bone pose estimation during movement using multi-body optimization

    Get PDF
    The financial support of the Universita'Italo-Francese (Call Vinci) and of the Department of Human Movement and Sport Sciences of the University of Rome ''Foro Italico'' is gratefully acknowledged. The authors wish to acknowledge Dr. Sophie Lacoste for her technical support and John McCamley for his contribution to the refinement of the manuscriptWhen using skin markers and stereophotogrammetry for movement analysis, bone pose estimation may be performed using multi-body optimization with the intent of reducing the effect of soft tissue artefacts. When the joint of interest is the knee, improvement of this approach requires defining subject-specific relevant kinematic constraints. The aim of this work was to provide these constraints in the form of plausible values for the distances between origin and insertion of the main ligaments (ligament lengths), during loaded healthy knee flexion, taking into account the indeterminacies associated with landmark identification during anatomical calibration. Ligament attachment sites were identified through virtual palpation on digital bone templates. Attachments sites were estimated for six knee specimens by matching the femur and tibia templates to low-dose stereoradiography images. Movement data were obtained using stereophotogrammetry and pin markers. Relevant ligament lengths for the anterior and posterior cruciate, lateral collateral, and deep and superficial bundles of the medial collateral ligaments (ACL, PCL, LCL, MCLdeep, MCLsup) were calculated. The effect of landmark identification variability was evaluated performing a Monte Carlo simulation on the coordinates of the origin-insertion centroids. The ACL and LCL lengths were found to decrease, and the MCLdeep length to increase significantly during flexion, while variations in PCL and MCLsup length was concealed by the experimental indeterminacy. An analytical model is given that provides subject-specific plausible ligament length variations as functions of the knee flexion angle and that can be incorporated in a multi-body optimization procedure

    The accuracy and precision of radiostereometric analysis in monitoring tibial plateau fractures

    Get PDF
    Background and purpose: The application of radiostereometric analysis (RSA) to monitor stability of tibial plateau fractures during healing is both limited and yet to be validated. We therefore evaluated the accuracy and precision of RSA in a tibial plateau fracture model. Methods: Combinations of 3, 6, and 9 markers in a lateral condyle fracture were evaluated with reference to 6 proximal tibial arrangements. Translation and rotation accuracy was assessed with displacement-controlled stages, while precision was assessed with dynamic double examinations. A comparison of error according to marker number and arrangement was completed with 2-way ANOVA models. Results: The results were improved using more tantalum markers in each segment. In the fracture fragment, marker scatter in all axes was achieved by a circumferential arrangement (medial, anterior, and lateral) of the tantalum markers above the fixation devices. Markers placed on either side of the tibial tuberosity and in the medial aspect of the fracture split represented the proximal tibial reference segment best. Using 6 markers with this distribution in each segment, the translation accuracy (root mean square error) was less than 37 μm in all axes. The precision (95% confidence interval) was less than ± 16 μm in all axes in vitro. Rotation, tested around the x-axis, had an accuracy of less than 0.123° and a precision of ± 0.024°. Interpretation: RSA is highly accurate and precise in the assessment of lateral tibial plateau fracture fragment movement. The validation of our center's RSA system provides evidence to support future clinical RSA fracture studies.Lucian B Solomon, Aaron W Stevenson, Stuart A Callary, Thomas R Sullivan, Donald W Howie, and Mellick J Chehad

    An overview of surface reconstruction using partial differential equation (PDE)

    Get PDF
    Surface reconstruction is the main process of reverse engineering where engineering model is reproduced in digital format. Surface reconstruction using PDE can be described as solving the PDE to generate the reconstructed surface of an object of interest. This paper provides a brief introduction to the process of surface reconstruction, partial differential equation and its application in surface reconstruction, as well as summarizing several works that utilize this approach. This paper also outlines the validation method used to assess a reconstruction model
    corecore