254 research outputs found

    A gain-coefficient switched Alexandrite laser

    Get PDF
    We report on a gain-coefficient switched Alexandrite laser. An electro-optic modulator is used to switch between high and low gain states by making use of the polarization dependent gain of Alexandrite. In gain-coefficient switched mode, the laser produces 85 ns pulses with a pulse energy of 240 mJ at a repetition rate of 5 Hz.Comment: 8 pages, 5 figure

    Mapping individual electromagnetic field components inside a photonic crystal

    Get PDF
    We present a method to map the absolute electromagnetic field strength inside photonic crystals. We apply the method to map the electric field component Ez of a two-dimensional photonic crystal slab at microwave frequencies. The slab is placed between two mirrors to select Bloch standing waves and a subwavelength spherical scatterer is scanned inside the resulting resonator. The resonant Bloch frequencies shift depending on the electric field at the position of the scatterer. To map the electric field component Ez we measure the frequency shift in the reflection and transmission spectrum of the slab versus the scatterer position. Very good agreement is found between measurements and calculations without any adjustable parameters.Comment: 12 pages, 7 figure

    Analysis of ultra-short bunches in free-electron lasers

    Get PDF
    Free-electron lasers (FELs) operate at wavelengths from millimeter waves through hard x-rays. At x-ray wavelengths, FELs typically rely on self-amplified spontaneous emission (SASE). Typical SASE emission contains multiple temporal 'spikes' which limit the longitudinal coherence of the optical output; hence, alternate schemes that improve on the longitudinal coherence of the SASE emission are of interest. In this paper, we consider electron bunches that are shorter than the SASE spike separation. In such cases, the spontaneously generated radiation consists of a single optical pulse with better longitudinal coherence than is found in typical SASE FELs. To investigate this regime, we use two FEL simulation codes. One (MINERVA) uses the slowly-varying envelope approximation (SVEA) which breaks down for extremely short pulses. The second (PUFFIN) is a particle-in-cell simulation code that is considered to be a more complete model of the underlying physics and which is able to simulate very short pulses. We first anchor these codes by showing that there is substantial agreement between the codes in simulation of the SPARC SASE FEL experiment at ENEA Frascati. We then compare the two codes for simulations using electron bunch lengths that are shorter than the SASE slice separation. The comparisons between the two codes for short bunch simulations elucidate the limitations of the SVEA in this regime but indicate that the SVEA can treat short bunches that are comparable to the cooperation length

    A design for the generation of temporally-coherent radiation pulses in the VUV and beyond by a self-seeding high-GaIn free electron laser amplifier

    Get PDF
    A proposal for a self-seeding, tunable free-electron laser amplifier operating in the vacuum ultra-violet (VUV) region of the spectrum is presented. Full three-dimensional (3D) modelling of the free electron laser and the optical feedback system has been carried out. Simulations demonstrate the generation of near transform limited radiation pulses with peak powers in the hundreds of megawatts. Preliminary 1D simulations show that by using a similar system it may be possible to extend such operation beyond the VUV to higher photon energies

    Diagnostic value of a heart-type fatty acid-binding protein (H-FABP) bedside test in suspected acute coronary syndrome in primary care

    Get PDF
    AbstractBackgroundTo determine the diagnostic accuracy of a rapid heart-type fatty acid-binding protein (H-FABP) test in patients suspected of acute coronary syndrome (ACS) in primary care.MethodsGeneral practitioners included 298 patients suspected of ACS. In all patients, whether referred to hospital or not, ECG and cardiac biomarker testing was performed. ACS was determined in accordance with international guidelines. Multivariate analysis was used to determine the value of H-FABP in addition to clinical findings.ResultsMean patient age was 66years (SD 14), 52% was female and 66 patients (22%) were diagnosed with ACS. The H-FABP bedside test was performed within 24h (median 3.1, IQR 1.5 to 7.1) after symptom onset. The positive predictive value (PPV) of H-FABP was 65% (95% confidence interval (CI) 50–78). The negative predictive value (NPV) was 85% (95% CI 80–88). Sensitivity was 39% (29–51%) and specificity 94% (90–96%). Within 6h after symptom onset, the PPV was 72% (55–84) and the NPV was 83% (77–88), sensitivity 43% (31–57%) and specificity 94% (89–97%). Adding the H-FABP test to a diagnostic model for ACS led to an increase in the area under the receiver operating curve from 0.66 (95% CI 0.58–0.73) to 0.75 (95% CI 0.68–0.82).ConclusionThe H-FABP rapid test provides modest additional diagnostic certainty in primary care. It cannot be used to safely exclude rule out ACS. The test can only be used safely in patients otherwise NOT referred to hospital by the GP, as an extra precaution not to miss ACS (‘rule in’)

    Detection of body postures and movements in ambulatory adults with cerebral palsy: a novel and valid measure of physical behaviour

    Get PDF
    BACKGROUND: Accurate measurement of physical behaviour is paramount to better understand lifestyle, health, and functioning, particularly in adults with physical disability as they may be at higher risk of sedentary lifestyle and subsequent negative health consequences. This study aimed: 1) to evaluate the criterion validity of a novel and clinically applicable activity monitor (AM, Activ8), in the detection of body postures and movements in adults with spastic cerebral palsy (CP); and 2) to evaluate the extent that the AM's positioning affects validity. METHODS: In this cross-sectional study, 14 ambulatory adults with CP [9 men; mean (SD) age, 35.4 (13.1) years] performed standardized activities while wearing three Activ8 monitors - frontolateral thigh (primary position), frontal thigh, and pant pocket - and being video recorded (criterion measure). AM activity output was compared to synchronized video recordings. Absolute (seconds) and relative [(video time-AM time)/mean time, %] time differences between methods were calculated. Relative time differences of < 10% were indicative of good validity. Comparison of AM attachment positions was completed using Spearman Rho correlation coefficients and Meng's tests. RESULTS: Criterion validity of the AM (frontolateral thigh) was good (average relative time differences: 0.25% for sitting, 4.69% for standing, 2.46% for walking, 1.96% for upright activity, 3.19% for cycling), except for running (34.6%). Spearman Rho correlation coefficients were greater between video/frontolateral thigh position than video/frontal thigh position and video/pant pocket position for body posture and movement categories sitting, standing, walking, and upright activity (p < 0.01 for all). CONCLUSIONS: The AM, positioned on the frontolateral thigh, demonstrated good criterion validity in ambulatory adults with CP. Though the Activ8 offers potential as an objective measure of physical activity, appropriate positioning is paramount for valid measurement

    Low bone mineral density in ambulatory persons with cerebral palsy? A systematic review

    Get PDF
    Purpose: Non-ambulatory persons with cerebral palsy are prone to low bone mineral density. In ambulatory persons with cerebral palsy, bone mineral density deficits are expected to be small or absent, but a consensus conclusion is lacking. In this systematic review bone mineral density in ambulatory persons with cerebral palsy (Gross Motor Function Classification Scales I–III) was studied. Materials and methods: Medline, Embase, and Web of Science were searched. According to international guidelines, low bone mineral density was defined as Z-score ≤ −2.0. In addition, we focused on Z-score ≤ −1.0 because this may indicate a tendency towards low bone mineral density. Results: We included 16 studies, comprising 465 patients aged 1–65 years. Moderate and conflicting evidence for low bone mineral density (Z-score ≤ −2.0) was found for several body parts (total proximal femur, total body, distal femur, lumbar spine) in children with Gross Motor Function Classification Scales II and III. We found no evidence for low bone mineral density in children with Gross Motor Function Classification Scale I or adults, although there was a tendency towards low bone mineral density (Z-score ≤ −1.0) for several body parts. Conclusions: Although more high-quality research is needed, results indicate that deficits in bone mineral density are not restricted to non-ambulatory people with cerebral palsy.Implications for Rehabilitation Although more high-quality research is needed, including adults and fracture risk assessment, the current study indicates that deficits in bone mineral density are not restricted to non-ambulatory people with CP. Health care professionals should be aware that optimal nutrition, supplements on indication, and an active lifestyle, preferably with weight-bearing activities, are important in ambulatory people with CP, also from a bone quality point-of-view. If indicated, medication and fall prevention training should be prescribed

    Aberrant Receptor-Mediated Endocytosis of Schistosoma mansoni Glycoproteins on Host Lipoproteins

    Get PDF
    BACKGROUND: Bilharzia is one of the major parasitic infections affecting the public health and socioeconomic circumstances in (sub) tropical areas. Its causative agents are schistosomes. Since these worms remain in their host for decades, they have developed mechanisms to evade or resist the immune system. Like several other parasites, their surface membranes are coated with a protective layer of glycoproteins that are anchored by a lipid modification. METHODS AND FINDINGS: We studied the release of glycosyl-phosphatidylinositol (GPI)-anchored proteins of S. mansoni and found them in the circulation associated with host lipoprotein particles. Host cells endocytosed schistosomal GPI-anchored proteins via their lipoprotein receptor pathway, resulting in disturbed lysosome morphology. In patients suffering from chronic schistosomiasis, antibodies attacked the parasite GPI-anchored glycoproteins that were associated with the patients' own lipoprotein particles. These immunocomplexes were endocytosed by cells carrying an immunoglobulin-Fc receptor, leading to clearance of lipoproteins by the immune system. As a consequence, neutral lipids accumulated in neutrophils of infected hamsters and in human neutrophils incubated with patient serum, and this accumulation was associated with apoptosis and reduced neutrophil viability. Also, Trypanosoma brucei, the parasite that causes sleeping sickness, released its major GPI-anchored glycoprotein VSG221 on lipoprotein particles, demonstrating that this process is generalizable to other pathogens/parasites. CONCLUSIONS: Transfer of parasite antigens to host cells via host lipoproteins disrupts lipid homeostasis in immune cells, promotes neutrophil apoptosis, may result in aberrant antigen presentation in host cells, and thus cause an inefficient immune response against the pathogen
    corecore