250 research outputs found

    A cost-utility analysis of transcatheter aortic valve implantation in Belgium: focusing on a well-defined and identifiable population

    Get PDF
    p. 1-8Objective To use patient-level data from the ADVANCE study to evaluate the cost-effectiveness of transcatheter aortic valve implantation (TAVI) compared to medical management (MM) in patients with severe aortic stenosis from the perspective of the UK NHS. Methods A published decision-analytic model was adapted to include information on TAVI from the ADVANCE study. Patient-level data informed the choice as well as the form of mathematical functions that were used to model all-cause mortality, health-related quality of life and hospitalisations. TAVI-related resource use protocols were based on the ADVANCE study. MM was modelled on publicly available information from the PARTNER-B study. The outcome measures were incremental cost-effectiveness ratios (ICERs) estimated at a range of time horizons with benefits expressed as quality-adjusted life-years (QALY). Extensive sensitivity/subgroup analyses were undertaken to explore the impact of uncertainty in key clinical areas. Results Using a 5-year time horizon, the ICER for the comparison of all ADVANCE to all PARTNER-B patients was £13 943 per QALY gained. For the subset of ADVANCE patients classified as high risk (Logistic EuroSCORE >20%) the ICER was £17 718 per QALY gained). The ICER was below £30 000 per QALY gained in all sensitivity analyses relating to choice of MM data source and alternative modelling approaches for key parameters. When the time horizon was extended to 10 years, all ICERs generated in all analyses were below £20 000 per QALY gained. Conclusion TAVI is highly likely to be a cost-effective treatment for patients with severe aortic stenosis

    Cost-effectiveness of cardiac resynchronisation therapy for patients with moderate-to-severe heart failure: a lifetime Markov model

    Get PDF
    1-7Objective To assess the cost-effectiveness of cardiac resynchronisation therapy (CRT) both with CRT-P (biventricular pacemaker only) and with CRT-D (biventricular pacemaker with defibrillator) in patients with New York Heart Association (NYHA) functional class III/IV from a Belgian healthcare-payer perspective. Methods A lifetime Markov model was designed to calculate the cost–utility of both interventions. In the reference case, the treatment effect was based on the Comparison of Medical Therapy, Pacing and Defibrillation in Heart Failure trial. Costs were based on real-world data. Pharmacoeconomic guidelines were applied, including probabilistic modelling and sensitivity analyses. Results Compared with optimal medical treatment, on average 1.31 quality-adjusted life-years (QALY) are gained with CRT-P at an additional cost of €14 700, resulting in an incremental cost-effectiveness ratio (ICER) of about €11 200/QALY. As compared with CRT-P, CRT-D treatment adds on average an additional 0.55 QALYs at an extra cost of €30 900 resulting in an ICER of €57 000/QALY. This result was very sensitive to the incremental clinical benefit of the defibrillator function on top of CRT. Conclusions Based on efficiency arguments, CRT-P can be recommended for NYHA class III and IV patients if there is a willingness to pay more than €11 000/QALY. Even though CRT-D may offer a survival benefit over CRT-P, the incremental clinical benefit appears to be too marginal to warrant a threefold-higher device price for CRT-D. Further clinical research should focus on the added value of CRT-D over CRT-P

    Testing the HTA Core Model: Experiences from two pilot projects

    Get PDF
    Objectives: The aim of this study was to analyze and describe process and outcomes of two pilot assessments based on the HTA Core Model, discuss the applicability of the model, and explore areas of development. Methods: Data were gathered from HTA Core Model and pilot Core HTA documents, their validation feedback, questionnaires to investigators, meeting minutes, emails, and discussions in the coordinating team meetings in the Finnish Office for Health Technology Assessment (FINOHTA). Results: The elementary structure of the HTA Core Model proved useful in preparing HTAs. Clear scoping and good coordination in timing and distribution of work would probably help improve applicability and avoid duplication of work. Conclusions: The HTA Core Model can be developed into a platform that enables and encourages true HTA collaboration in terms of distribution of work and maximum utilization of a common pool of structured HTA information for national HTA report

    Safety of percutaneous aortic valve insertion. A systematic review

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The technique of percutaneous aortic valve implantation (PAVI) for the treatment of severe aortic stenosis (AS) has been introduced in 2002. Since then, many thousands such devices have worldwide been implanted in patients at high risk for conventional surgery. The procedure related mortality associated with PAVI as reported in published case series is substantial, although the intervention has never been formally compared with standard surgery. The objective of this study was to assess the safety of PAVI, and to compare it with published data reporting the risk associated with conventional aortic valve replacement in high-risk subjects.</p> <p>Methods</p> <p>Studies published in peer reviewed journals and presented at international meetings were searched in major medical databases. Further data were obtained from dedicated websites and through contacts with manufacturers. The following data were extracted: patient characteristics, success rate of valve insertion, operative risk status, early and late all-cause mortality.</p> <p>Results</p> <p>The first PAVI has been performed in 2002. Because of procedural complexity, the original transvenous approach from 2004 on has been replaced by the transarterial and transapical routes. Data originating from nearly 2700 non-transvenous PAVIs were identified. In order to reduce the impact of technical refinements and the procedural learning curve, procedure related safety data from series starting recruitment in April 2007 or later (n = 1975) were focused on. One-month mortality rates range from 6.4 to 7.4% in transfemoral (TF) and 11.6 to 18.6% in transapical (TA) series. Observational data from surgical series in patients with a comparable predicted operative risk, indicate mortality rates that are similar to those in TF PAVI but substantially lower than in TA PAVI. From all identified PAVI series, 6-month mortality rates, reflecting both procedural risk and mortality related to underlying co-morbidities, range from 10.0-25.0% in TF and 26.1-42.8% in TA series. It is not known what the survival of these patients would have been, had they been treated medically or by conventional surgery.</p> <p>Conclusion</p> <p>Safety issues and short-term survival represent a major drawback for the implementation of PAVI, especially for the TA approach. Results from an ongoing randomised controlled trial (RCT) should be awaited before further using this technique in routine clinical practice. In the meantime, both for safety concerns and for ethical reasons, patients should only be subjected to PAVI within the boundaries of such an RCT.</p

    Regional differences in the pattern of airway remodeling following chronic allergen exposure in mice

    Get PDF
    BACKGROUND: Airway remodeling present in the large airways in asthma or asthma models has been associated with airway dysfunction in humans and mice. It is not clear if airways distal to the large conducting airways have similar degrees of airway remodeling following chronic allergen exposure in mice. Our objective was to test the hypothesis that airway remodeling is heterogeneous by optimizing a morphometric technique for distal airways and applying this to mice following chronic exposure to allergen or saline. METHODS: In this study, BALB/c mice were chronically exposed to intranasal allergen or saline. Lung sections were stained for smooth muscle, collagen, and fibronectin content. Airway morphometric analysis of small (0–50000 μm(2)), medium (50000 μm(2)–175000 μm(2)) and large (>175000 μm(2)) airways was based on quantifying the area of positive stain in several defined sub-epithelial regions of interest. Optimization of this technique was based on calculating sample sizes required to detect differences between allergen and saline exposed animals. RESULTS: Following chronic allergen exposure BALB/c mice demonstrate sustained airway hyperresponsiveness. BALB/c mice demonstrate an allergen-induced increase in smooth muscle content throughout all generations of airways, whereas changes in subepithelial collagen and fibronectin content are absent from distal airways. CONCLUSION: We demonstrate for the first time, a systematic objective analysis of allergen induced airway remodeling throughout the tracheobronchial tree in mice. Following chronic allergen exposure, at the time of sustained airway dysfunction, BALB/c mice demonstrate regional differences in the pattern of remodeling. Therefore results obtained from limited regions of lung should not be considered representative of the entire airway tree

    Semi-Automatic Measurement of the Airway Dimension by Computed Tomography Using the Full-Width-Half-Maximum Method: a Study on the Measurement Accuracy according to the CT Parameters and Size of the Airway

    Get PDF
    Objective: To assess the influence of variable factors such as the size of the airway and the CT imaging parameters such as the reconstruction kernel, field-ofview (FOV), and slice thickness on the automatic measurement of airway dimension. Materials and Methods: An airway phantom was fabricated that contained eleven poly-acryl tubes of various lumen diameters and wall thicknesses. The measured density of the poly-acryl wall was 150 HU, and the measured density of the airspace filled with polyurethane foam was 900 HU. CT images were obtained using a 16-MDCT (multidetector CT) scanner and were reconstructed with various reconstruction kernels, thicknesses and FOV. The luminal radius and wall thickness were measured using in-house software based on the fullwidth- half-maximum method. The measured values as determined by CT and the actual dimensions of the tubes were compared. Results: Measurements were most accurate on images reconstructed with use of a standard kernel (mean error: 0.03+-0.21 mm for wall thickness and 0.12 0.11 mm for the luminal radius). There was no significant difference in accuracy among images with the use of variable slice thicknesses or a variable FOV. Below a 1-mm threshold, the measurement failed to represent the change of the real dimensions. Conclusion: Measurement accuracy was strongly influenced by the specific reconstruction kernel utilized. For accurate measurement, standardization of the imaging protocol and selection of the appropriate anatomic level are essential.This work was supported by a Korea Science and Engineering Foundation (KOSEF) grant funded by the Korea government (MOST) (No. R01-2006-000-11244-0)
    corecore